AMSCO V-PRO 1 LOW TEMPERATURE STERILIZATION SYSTEM; AMSCO V-PRO 1 PLUS LOW TEMPERATURE STERILIZATION SYSTEM

K102394 · STERIS Corporation · MLR · Aug 18, 2011 · General Hospital

Device Facts

Record IDK102394
Device NameAMSCO V-PRO 1 LOW TEMPERATURE STERILIZATION SYSTEM; AMSCO V-PRO 1 PLUS LOW TEMPERATURE STERILIZATION SYSTEM
ApplicantSTERIS Corporation
Product CodeMLR · General Hospital
Decision DateAug 18, 2011
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 880.6860
Device ClassClass 2

Indications for Use

The Amsco V-PRO 1 and V-PRO 1 Plus Low Temperature Sterilization Systems, with VAPROX HC Sterilant, are vaporized hydrogen peroxide sterilizers intended for use in the terminal sterilization of cleaned, rinsed and dried reusable metal and nonmetal medical devices used in healthcare facilities. The pre-programmed sterilization cycles operate at low pressure and low temperature and are thus suitable for processing medical devices sensitive to heat and moisture. The V-PRO 1 Cycle, which is identical to the V-PRO 1 Plus Lumen Cycle, was cleared under K062297 and can sterilize: * Instruments with diffusion-restricted spaces such as the hinged portion of forceps and scissors * Medical devices with a single stainless steel lumen with: . an inside diameter of 1 mm or larger and a length of a 125 mm or shorter o an insider diameter of 2 mm or larger and a length of 250 mm or shorter o an inside diameter of 3 mm or larger and a length of 400 mm or shorter * The validation testing for all lumen sizes was conducted using a maximum of twenty (20) lumens per load. Hospital loads should not exceed the maximum number of lumens validated by this testing. The validation studies were performed using a validation load consisting of two instrument trays and two pouches for a total weight of 19.65 lbs. The Amsco V-PRO 1 Plus Low Temperature Sterilization System's Non Lumen Cycle was cleared under K.083097 and can sterilize: ** Non-lumened instruments including non-luments with stainless steel diffusion-restricted areas such as the hinged portion of forceps or scissors. ** The validation studies were conducted using a validation load consisting of two instrument trays and two pouches for a total weight of 19.65 lbs.

Device Story

Self-contained, stand-alone vaporized hydrogen peroxide sterilizers; used in healthcare facilities for terminal sterilization of heat/moisture-sensitive reusable medical devices. Devices process cleaned, rinsed, and dried metal and nonmetal instruments, including those with diffusion-restricted spaces or specific stainless steel lumens. Operation involves pre-programmed low-pressure, low-temperature cycles using VAPROX HC Sterilant. Healthcare providers load instruments into trays/pouches; system provides automated sterilization cycle. Benefits include effective sterilization of sensitive materials (now including PEEK and polyurethane) without heat damage. Output confirms sterilization efficacy for clinical reuse.

Clinical Evidence

Bench testing only. Studies included biocompatibility (cytotoxicity/residue analysis), material compatibility, ½ cycle sterilization efficacy, simulated use evaluation, and in-use evaluation. All tests passed, confirming no survivors on device surfaces and maintained functionality for PEEK and polyurethane materials.

Technological Characteristics

Vaporized hydrogen peroxide sterilizer; operates at low pressure and low temperature. Compatible with metal and nonmetal materials, including PEEK and polyurethane. Stand-alone form factor. Uses VAPROX HC Sterilant. Pre-programmed sterilization cycles.

Indications for Use

Indicated for terminal sterilization of cleaned, rinsed, and dried reusable metal and nonmetal medical devices in healthcare facilities. Suitable for heat- and moisture-sensitive devices, including instruments with diffusion-restricted spaces (hinged forceps/scissors) and specific stainless steel lumens (1mm x 125mm, 2mm x 250mm, 3mm x 400mm).

Regulatory Classification

Identification

An ethylene gas sterilizer is a nonportable device intended for use by a health care provider that uses ethylene oxide (ETO) to sterilize medical products.

Predicate Devices

Submission Summary (Full Text)

{0}------------------------------------------------ pl of STERIS AUG 18 2011 # 510(k) Summary For 1 and V-PRO™ 1 Plus Low Temperature Amsco® V-PR Sterilization Systems STERIS Corporation 5960 Heisley Road Mentor, OH 44060 Phone: (440) 354-2600 Fax No: (440) 357-9198 Contact: Robert Sullivan Senior Director, FDA Regulatory Affairs Tel: 440-392-7695 Fax: 440-357-9198 Submission Date: July 27, 2011 STERIS Corporation ■ 5960 Heisley Road ■ Mentor, OH 44060-1834 USA ■ 440-354-2600 {1}------------------------------------------------ \$\overline{K102394}\$ p2d4 #### 1. Device Name Trade Name: | | System and Amsco V-PRO 1 Plus Low<br>Temperature Sterilization System | |------------------------|-----------------------------------------------------------------------| | Common/usual Name: | Vapor Phase Hydrogen Peroxide Sterilizer | | Classification Name: | Sterilizer, Ethylene Oxide Gas | | Classification Number: | 21 CFR 880.6860 | | Product Code: | MLR | Amsco V-PRO 1 Low Temperature Sterilization #### 2. Predicate Device Amsco® V-PROTM 1 Low Temperature Sterilization System (K062297) Amsco® V-PRO™ 1 Plus Low Temperature Sterilization System (K083097) #### 3. Description of Device The Amsco V-PRO 1 and V-PRO 1 Plus Low Temperature Sterilizers are selfcontained stand-alone devices using vaporized hydrogen peroxide. These devices are intended for use in terminal sterilization of cleaned, rinsed and dried, reusable medical devices used in healthcare facilities. The sterilizers operate at low pressure and low temperature and are therefore suitable for processing medical devices sensitive to heat and moisture. #### 4. Intended Use The Amsco V-PRO 1 and V-PRO 1 Plus Low Temperature Sterilization Systems, with VAPROX HC Sterilant, are vaporized hydrogen peroxide sterilizers intended for use in the terminal sterilization of cleaned, rinsed and dried reusable metal and nonmetal medical devices used in healthcare facilities. The pre-programmed sterilization cycles operate at low pressure and low temperature and are thus suitable for processing medical devices sensitive to heat and moisture. The V-PRO 1 Cycle, which is identical to the V-PRO 1 Plus Lumen Cycle, was cleared under K062297 and can sterilize: * - Instruments with diffusion-restricted spaces such as the hinged portion of . forceps and scissors - Medical devices with a single stainless steel lumen with: . - an inside diameter of 1 mm or larger and a length of a 125 mm or shorter o {2}------------------------------------------------ - p 3d 4 an insider diameter of 2 mm or larger and a length of 250 mm or shorter o - an inside diameter of 3 mm or larger and a length of 400 mm or shorter o - * The validation testing for all lumen sizes was conducted using a maximum of twenty (20) lumens per load. Hospital loads should not exceed the maximum number of lumens validated by this testing. The validation studies were performed using a validation load consisting of two instrument trays and two pouches for a total weight of 19.65 lbs. The Amsco V-PRO 1 Plus Low Temperature Sterilization System's Non Lumen Cycle was cleared under K.083097 and can sterilize: ** Non-lumened instruments including non-luments with stainless steel diffusion-restricted areas such as the hinged portion of forceps or scissors. - ** The validation studies were conducted using a validation load consisting of two instrument trays and two pouches for a total weight of 19.65 lbs. #### ഗ് Description of Safety and Substantial Equivalence The Amsco V-PRO 1 and V-PRO 1 Plus Low Temperature Sterilization Systems are the same as the predicate devices (K062297 and K083097) except for a proposed change to the device Operator Manual to include polyether ether ketone (PEEK) as a compatible material for the V-PRO 1 Cycle and V-PRO 1 Plus Lumen and Non Lumen Cycles; and polyurethane as a compatible material for the V-PRO 1 Plus Non Lumen Cycle. These proposed labeling changes to add these materials as compatible with VAPROX HC Sterilant do not affect the design or performance specifications of the devices and no new concerns arise regarding the safety and effectiveness when compared to the predicate devices. The following table summarizes the verification activities that were performed with their respective acceptance criteria to ensure the safety and effectiveness of processing PEEK-containing materials in the V-PRO 1 Cycle and V-PRO 1 Plus Lumen and Non Lumen Cycles and polyurethane-containing materials in the V-PRO 1 Plus Non Lumen Cycle. Each test listed was completed for both polyurethane and PEEK. The differences between the proposed and predicate device are limited to the described modifications of the device and these proposed changes raise no new concerns of safety and effectiveness when compared to the predicate device. The proposed Amsco V-PRO 1 and V-PRO 1 Plus Low Temperature Sterilization Systems are substantially equivalent to the predicate. K102394 {3}------------------------------------------------ K102394/S002 STERIS Response to 03/14/11 Request for Additional Information Amsco V-PRO 1 and V-PRO 1 Plus Low Temperature Sterilization Systems | Test | Acceptance Criteria | Result | |-----------------------------------|---------------------------------------------------------------------------------------------------------------------|--------| | Biocompatibility | Cytotoxicity and residue analysis have<br>demonstrated biocompatibility after<br>processing in the V-PRO sterilizer | Pass | | Material<br>compatibility | Device maintains functionality following<br>sterilization | Pass | | ½ Cycle sterilization<br>efficacy | No survivors at ½ cycle condition with<br>End Of Shelf Life Sterilant | Pass | | Simulated Use<br>evaluation | No survivors on device surface after<br>processing with the V-PRO Non Lumen<br>Cycle using EOSL sterilant | Pass | | In Use evaluation | Sterile results on all polyurethane and<br>PEEK containing devices | Pass | p. 40 4 {4}------------------------------------------------ Image /page/4/Picture/2 description: The image shows a logo for the Department of Health and Human Services. The logo consists of a stylized eagle with three lines representing its wings and body. The words "DEPARTMENT OF HEALTH" are written vertically along the left side of the logo. Food and Drug Administration 10903 New Hampshire Avenue Document Control Room -WO66-G609 Silver Spring, MD 20993-0002 Mr. Robert Sullivan Senior Director. FDA Regulatory Affairs STERIS Corporation 5960 Heisley Road Mentor, Ohio 44060 1 8 2011 ୟାତି Re: K102394 Trade/Device Name: Amsco® V-PRO™ 1 Low Temperature Sterilization System and Amsco® V-PRO™ 1 Plus Low Temperature Sterilization System Regulation Number: 21 CFR 880.6860 Regulation Name: Ethylene Oxide Gas Sterilizer Regulatory Class: II Product Code: MLR Dated: July 27, 2011 Received: July 28, 2011 Dear Mr. Sullivan: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. {5}------------------------------------------------ ## Page 2 - Mr. Sullivan Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801). please go to http://www.fda.gov/AboutFDA/CentersOffices/CDRH/CDRHOffices /ucm115809.htm for the Center for Devices and Radiological Health's (CDRH's) Office of Compliance. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803). please go to http://www.fda.gov/MedicalDevices/Safety/ReportalProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance. You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default.htm. Sincerely yours, Anton van Anthony D. Watson, B.S., M.S., M.B.A. Director Division of Anesthesiology, General Hospital; Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health ### Enclosure {6}------------------------------------------------ # Indications for Use 510(k) Number (if known): Device Name: Amsco® V-PRO™ 1 Low Temperature Sterilization System Amsco V-PROTM 1 Plus Low Temperature Sterilization System Indications For Use: The Amsco V-PRO 1 and V-PRO 1 Plus Low Temperature Sterilization Systems, with VAPROX HC Sterilant, are vaporized hydrogen peroxide sterilizers intended for use in the terminal sterilization of cleaned, rinsed and dried reusable metal and nonmetal medical devices used in healthcare facilities. The pre-programmed sterilization cycles operate at low temperature and are thus suitable for processing medical devices sensitive to heat and moisture. The V-PRO 1 Cycle, which is identical to the V-PRO 1 Plus Lumen Cycle, was cleared under K062297 and can sterilize:* - . Instruments with diffusion-restricted spaces such as the hinged portion of forceps and scissors - Medical devices with a single stainless steel lumen with: . o an inside diameter of 1 mm or larger and a length of a 125 mm or shorter o an insider diameter of 2 mm or larger and a length of 250 mm or shorter - o an inside diameter of 3 mm or larger and a length of 400 mm or shorter - * The validation testing for all lumen sizes was conducted using a maximum of twenty (20) lumens per load. Hospital loads should not exceed the maximum number of lumens validated by this testing. The validation studies were performed using a validation load consisting of two instrument trays and two pouches for a total weight of 19.65 lbs. The Amsco V-PRO 1 Plus Low Temperature Sterilization System's Non Lumen Cycle was cleared under K083097 and can sterilize. ** Non-lumened instruments including non-luments with stainless steel diffusion-restricted areas such as the hinged portion of forceps or scissors. - ** The validation studies were conducted using a validation load consisting of two instrument trays and two pouches for a total weight of 19.65 lbs. | Prescription Use<br>(Part 21 CFR 801 Subpart D) | AND/OR | |-------------------------------------------------|--------| |-------------------------------------------------|--------| Over-The-Counter Use X (21 CFR 801 Subpart C) ## (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED) rrence of CDRH, Office of Device Evaluation (ODE) Division of Anesthesiology, General Hospital Infection Control, Dental Devices K102294 510(k) Number: Page 1 of 1
Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...