The AgaChamber Spacer is intended to be used by patients, who are under the care or treatment of a licensed healthcare provider or physician. The device is intended to be used by these patients to administer aerosolized medication from most pressurized Metered Dose Inhalers, prescribed by a physician or healthcare professional. The device has been developed for use, with or without mask, in accordance with necessity and medical orientation. The intended environments for use include home, hospitals and clinics.
Device Story
AgaChamber Spacer is a passive, conical chamber device; acts as a space extension between a Metered Dose Inhaler (MDI) and the patient's nose/mouth. Input: aerosolized medication from an MDI. Operation: patient fits nozzle or mask over nose/mouth to inhale medication; device facilitates delivery to lungs. Used in home, hospitals, and clinics by patients under medical supervision. No active components; device is latex-free and constructed of wrought plastic via thermoplastic injection. Benefits: maximizes efficacy of inhaled medications for respiratory ailments.
Clinical Evidence
Bench testing only. Performance verified via biocompatibility testing (ISO 10993-10:2002/AM:2006 and ISO 10993-5:2009) and Aerosol Performance Testing per FDA guidance for Nebulizers, MDI's, Spacers and Actuators. Device met all pre-determined pass/fail criteria.
Technological Characteristics
Passive spacer device; wrought plastic construction; thermoplastic injection assembly. Dimensions: conical chamber with MDI orifice and nozzle/mask interface. No energy source. Latex-free. Biocompatibility per ISO 10993. No software or electronic components.
Indications for Use
Indicated for patients under care of a healthcare provider requiring administration of aerosolized medication from pressurized Metered Dose Inhalers. Suitable for adults and children, with or without mask, for respiratory ailments.
Regulatory Classification
Identification
A nebulizer is a device intended to spray liquids in aerosol form into gases that are delivered directly to the patient for breathing. Heated, ultrasonic, gas, venturi, and refillable nebulizers are included in this generic type of device.
Predicate Devices
Aerochamber Plus Anti-Static Valved Hold (K070674)
Submission Summary (Full Text)
{0}------------------------------------------------
K101348
# Exhibit 1
# 510(K) SUMMARY
APR 2 9 2011
This summary of 510(k) safety and effectiveness information is being submitted in accordance with the requirements of SMDA 1990 and 21 CFR §807.92.
The assigned 5l0(k) number is:
## Submitter's Identification: 1.
Agaplastic Industria e Comercie Ltda. Rue Cuba, 353 Rio de Janeiro RJ Brasil CEP:210-160
Tel.: 55 21 2573 0969 Fax.: 55 21 2573 2336
Date Summary Prepared: November 10, 2010
### 2. Name of the Device:
Proprietary name: Agachamber Spacer with mask
- 21 CFR 868.5630, Class II 3. Classification: Product Code: NVP
### 4. Common or Usual Name:
Common name: Spacer Classification name: Nebulizer (Direct Patient Interface)
### Predicate Device Information: 5.
# a) Legally Marketed Equivalent Device:
Aerochamber Plus Anti-Static Valved Hold Manufactured by Trudell Medical International with 510k Number: K070674. Product code: NVP
### 6. AgaChamber Spacer Description:
AgaChamber Spacer is composed of a conical chamber with openings on both of its sides, where in one of these opening there is an attached base
{1}------------------------------------------------
with an orifice into which the medication dose is inserted and the Metered Dose Inhaler dispenses the medication. On the other side, there is a nozzle which holds the mask. which the patient will fit over his/her nose and mouth so that the medication can be inhaled. The device has been developed for use, with or without mask.
The percentage of the drug dose delivered into the chamber is totally dependent on the Metered Dose Inhaler's pressure and guantity of metered doses the healthcare provider prescribes. Another point that should be clear is that, AgaChamber is a passive device and its main function is to provide a space extension between the Metered Dose Inhaler and the patient's nose and mouth in order to facilitate the inhalation of the medication.
- AgaChamber is composed of wrought plastic parts and assembled I together by a process of thermoplastic injection.
- IMPORTANT NOTE: AGACHAMBER SPACER IS LATEX FREE ..
#### 7. Intended Use:
The AgaChamber Spacer is intended to be used by patients, who are under the care or treatment of a licensed healthcare provider or physician. The device is intended to be used by these patients to administer aerosolized medication from most pressurized Metered Dose Inhalers, prescribed by a physician or healthcare professional. The device has been developed for use, with or without mask, in accordance with necessity and medical orientation. The intended environments for use include home, hospitals and clinics.
#### Technological Characteristics: 8.
AgaChamber's techonological characteristics are similar to the legally marketed equivalent. AeroChamber, from its basic material compositions (please see images below), to its function, as well as its intended use, which is classified as; "to facilitate the use of an inhaler and to improve the passage of medication to the lungs".
AgaChamber has been developed for adult and child use, with or without the use of the mask, in accordance with necessity and medical orientation. AgaChamber, likewise legally marketed AeroChamber, is to be used according to a doctor's orientation.
There are no distinctions in the usage of AgaChamber and AeroChamber, both are intended to maximize the efficacy of inhaling medications that need to be delivered to the lungs to treat respiratory ailments. Both have the same overall structure and carry on the same delivery process,
{2}------------------------------------------------
therefore both serve for the same purposes. (Please see images below.)
Image /page/2/Picture/10 description: The image shows two different brands of medical inhaler chambers. On the left is an "Aerochamber" inhaler chamber, which is a small, clear plastic tube with a black mouthpiece. On the right is an "AgaChamber" inhaler chamber, which is a larger, clear plastic tube with a white mask attached to the end. The AgaChamber also has instructions printed on the side of the chamber.
### 9. Performance Data:
Non-clinical: Verification, validation and testing activities were conducted to establish the performance, functionality and reliability characteristics of the Agachamber Spacer with mask with respect to the predicate device.
Third party testing was performed including biocompatibility testing per ISO 10993-10:2002/AM:2006 and ISO10993-5:2009 as well as Aerosol Performance Testing per the FDA Guidance document "Reviewer Guidance for Nebulizers, MDI's, Spacers and Actuators".
The device passed all of the tests based on pre-determined Pass/Fail criteria.
#### 10. Conclusions:
The data from the biocompatibility and non clinical tests show that the Agachamber Spacer with mask is as safe and effective as the legally marketed predicate device.
Therefore we conclude that the Agachamber Spacer with mask is substantially equivalent to the predicate device.
{3}------------------------------------------------
Image /page/3/Picture/1 description: The image shows the seal for the Department of Health & Human Services - USA. The seal is circular and contains the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" around the perimeter. In the center of the seal is an abstract image of an eagle.
Food and Drug Administration 10903 New Hampshire Avenue Document Control Room -WO66-G609 Silver Spring, MD 20993-0002
Agalastic Industria e Comercie Ltda. C/O Ms. Maria F. Griffin Official Correspondent MDI Consultants, Incorporated 55 Northern Boulevard, Suite 200 Great Neck, New York 11021
APR 2 9 2011
Re: K101348
Trade/Device Name: AgaChamber Spacer Regulation Number: 21 CFR 868.5630 Regulation Name: Nebulizer Regulatory Class: II Product Code: NVP Dated: April 21, 2011 Received: April 22, 2011
Dear Ms. Griffin:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Eederal Register.
{4}------------------------------------------------
Page 2- Ms. Griffin
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please go to http://www.fda.gov/AboutFDA/CentersOffices/CDRH/CDRHOffices /ucm115809.htm for the Center for Devices and Radiological Health's (CDRH's) Office of Compliance. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default.htm.
Sincerely yours,
Wh for
Anthony D. Watson, B.S., M.S., M.B.A. Director Division of Anesthesiology, General Hospital, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health
{5}------------------------------------------------
# INDICATIONS FOR USE
510(k) Number (if known):
Device Name: AgaChamber Spacer
Indications For Use:
The AgaChamber Spacer is intended to be used by patients, who are under the care or treatment of a licensed healthcare provider or physician. The device is intended to be used by these patients to administer aerosolized medication from most pressurized Metered Dose Inhalers, prescribed by a physician or healthcare professional. The device has been developed for use, with or without mask, in accordance with necessity and medical orientation. The intended environments for use include home, hospitals and clinics.
Prescription Use X
Over-The Counter Use
(Per 21 CFR 801 Subpart D) OR (21 CFR 807 Subpart C)
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
L. Schutter
Division Sign-Off) Tivision of Anesthesiology, General Hospital fection Control, Dental Devices
4101348 10(k) Number:
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Guidance alerts
New and changed FDA guidance documents, emailed as a daily digest.
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the ? button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only Software as a Medical Device, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (Software as a Medical Device), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.