BEL-CAT

K101181 · Takara Belmont Corp. · OAS · Jul 19, 2011 · Radiology

Device Facts

Record IDK101181
Device NameBEL-CAT
ApplicantTakara Belmont Corp.
Product CodeOAS · Radiology
Decision DateJul 19, 2011
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 892.1750
Device ClassClass 2

Indications for Use

Bel-Cat is an x-ray device (cone beam computed tomography) that acquires a single 360 degree rotational sequence of the head and neck areas, including the ENT and dentomaxillofacial area for use in diagnostic support. The device is operated and used by physicians, dentists, and x-ray technologists. (Not for mammographic use.)

Device Story

Bel-Cat is an arm-type X-ray cone beam computed tomography (CBCT) system; acquires 360-degree rotational sequences of head/neck, ENT, and dentomaxillofacial regions. Operated by physicians, dentists, or technologists in clinical settings. System offers customizable exposure modes (Panoramic, CT, Cephalometric) to deliver high-definition diagnostic images. Input consists of X-ray projections; system transforms these into reconstructed CT images for diagnostic support. Output allows clinicians to visualize anatomical structures, aiding clinical decision-making and diagnosis. Benefits include high-definition imaging for dental and maxillofacial applications.

Clinical Evidence

Bench testing and external laboratory testing were performed to verify performance against applicable standards. No clinical trial data was required or presented to establish substantial equivalence.

Technological Characteristics

Arm-type X-ray CBCT system. X-ray source: 60-95 kV, 2-12 mA, 0.5mm x 0.5mm focal spot. Detectors: Varian 2520 (250mm x 200mm, 127µm pixel) or Varian 1313 (130mm x 130mm, 127µm pixel). Power: AC 220V, 50/60 Hz. Modes: CT, Panoramic, Cephalometric. Connectivity: Standalone diagnostic imaging system.

Indications for Use

Indicated for diagnostic support via cone beam CT imaging of head, neck, ENT, and dentomaxillofacial areas. Intended for use by physicians, dentists, and x-ray technologists. Not for mammographic use.

Regulatory Classification

Identification

A computed tomography x-ray system is a diagnostic x-ray system intended to produce cross-sectional images of the body by computer reconstruction of x-ray transmission data from the same axial plane taken at different angles. This generic type of device may include signal analysis and display equipment, patient and equipment supports, component parts, and accessories.

Predicate Devices

Submission Summary (Full Text)

{0}------------------------------------------------ JUL 19 2011 ### 510(k) Summary 510(k) Number K10 1 / 8 / TAKARA BELMONT CORPORATION 1-1-2 CHOME, HIGASHI-SHINSAIBASHI, CHUO-KU Osaka 542 Japan Tel: 81-6-6213-5945 Fax: 81-6-6212-3680 Date Prepared: April 19, 2010 Tomokuni Hasegawa, Senior VP Contact: - 1. Identification of the Device: Proprietary-Trade Name: Bel-Cat Dental Cone Beam CT Classification Name: Computed Tomography X-Ray System Product Code 90 OAS Common/Usual Name: Dental CT - Equivalent legally marketed device: TAKARA BELMONT Alphard K072574 2. - 3. Indications for Use (intended use) Bel-Cat is an x-ray device (cone beam computed tomography) that acquires a single 360 degree rotational sequence of the head and neck areas, including the ENT and dentomaxillofacial area for use in diagnostic support. The device is operated and used by physicians, dentists, and x-ray technologists. (Not for mammographic use.) - 4. Description of the Device: The Bel-Cat series is a set of arm type X-ray CT diagnostic devices which has exposure modes can be customized to meet a wide variety of diverse diagnostic imaging needs. The Bel-Cat series is a true all-in-one system capable of offering diverse acquisition modes that deliver the high-definition images demanded in dental fields. | Model | Bel-Ca: | Bel-Ca: PA | Bel-Ca1 CM | |----------------------|---------|------------|------------| | Exposure modes | | | | | CCD<br>Panoramic | | | | | CCD<br>Cephalometric | | | | | FPD<br>Panoramic | | | | | CT | | | | - Safety and Effectiveness, comparison to predicate device. The results of bench, test 5. laboratory and clinical testing indicates that the new device is as safe and effective as the predicate devices. {1}------------------------------------------------ | Model | TAKARA BELMONT Alphard<br>K072574 | TAKARA BELMONT Bel-Cat | |-----------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | Indication<br>for use | An x-ray device (cone beam computed<br>tomography) that acquires a single 360<br>degree rotational sequence of the head<br>and neck areas, including the ENT and<br>dentomaxillofacial area for use in<br>diagnostic support. The device is operated<br>and used by physicians, dentists, and x-<br>ray technologists. | SAME | | Specification<br>comparison | Focal spot: 0.6mm×0.6mm<br>Tube voltage 60-100 kV<br>Tube current: 2-15 mA<br>Exposure time: 17 sec maximum<br>Input: 3 kVa<br>Power supply: AC 220 v, 50/60 Hz.<br>Projection mode: CT, Panoramic<br>Detector dimension:<br>Two sizes available:<br>Varian 2520: 250mm x 200mm Pixel size<br>127µm x 127µm<br>1536 x 1920 pixels<br>Varian 3030, 300mm x 300mm, Pixel<br>size<br>194µm x 194µm<br>1536 x 1536 pixels | Focal spot: 0.5mm×0.5mm<br>Tube voltage 60-95 kV<br>Tube current: 2-12 mA<br>Exposure time: 17 sec maximum<br>Input: 2 kVa<br>Power supply: AC 220 v, 50/60 Hz.<br>Projection mode: CT, Panoramic<br>Detector dimension:<br>Two sizes available:<br>Varian 2520: 250mm x 200mm Pixel size<br>127µm x 127µm<br>1536 x 1920 pixels<br>Varian 1313, 130mm x130mm, Pixel<br>size<br>127µm x 127µm<br>1024 x 1024 pixels | ### 6. Substantial Equivalence Chart #### 7. Conclusion After analyzing both bench test data as well as external laboratory testing to applicable standards, it is the conclusion of Takara Belmont Corporation that the Bel-Cat Dental Cone Beam CT System is as safe and effective as the predicate device, has few technological differences, and has no new indications for use, thus rendering it substantially equivalent to the predicate devices. {2}------------------------------------------------ Image /page/2/Picture/0 description: The image shows the seal of the Department of Health & Human Services (HHS) of the United States. The seal features a stylized eagle with its wings spread, symbolizing protection and service. Encircling the eagle is the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA", indicating the department's name and national affiliation. ## DEPARTMENT OF HEALTH & HUMAN SERVICES Public Health Service Food and Drug Administration 10903 New Hampshire Avenue Document Control Room - WO66-G609 Silver Spring, MD 20993-0002 Takara Blemont Corp. % Mr. Daniel Kamm, P.E. Regulatory Engineer, Submission Correspondent Kamm & Associates 8870 Ravello Ct NAPLES FL 34114 JUL 19 2011 Re: K101181 Trade/Device Name: Bel-Cat (various models) Regulation Number: 21 CFR 892.1750 Regulation Name: Computed tomography x-ray system Regulatory Class: II Product Code: OAS Dated: May 25, 2011 Received: May 27, 2011 Dear Mr. Kamm: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into class II (Special Controls), it may be subject to such additional controls. Existing major regulations affecting your device can be found in Title 21, Code of Federal Regulations (CFR), Parts 800 to 895. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Parts 801 and 809); medical device reporting (reporting of {3}------------------------------------------------ medical device-related adverse events) (21 CFR 803); and good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820). This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Parts 801 and 809), please contact the Office of In Vitro Diagnostic Device Evaluation and Safety at (301) 796-5450. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance. You may obtain other general information on your responsibilities under the Act from the " Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html. Sincerely Yours. Mary Pastel Mary S. Pastel, Sc.D. Director Division of Radiological Devices Office of In Vitro Diagnostic Device Evaluation and Safety Center for Devices and Radiological Health Enclosure {4}------------------------------------------------ # Indications for Use 510(k) Number (if known): K10 // 81 Device Name: Bel-Cat (various models) Indications For Use: This is an x-ray device (cone beam computed tomography) that acquires a single 360 degree rotational sequence of the head and neck areas, including the ENT and dentomaxillofacial area for use in diagnostic support. The device is operated and used by physicians, dentists, and x-ray technologists. Not for mammographic use. Prescription Use _X (Part 21 CFR 801 Subpart D) AND/OR Over-The-Counter Use _ (21 CFR 807 Subpart C) (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) (Division Sign-Off) Division of Radiologica Office of In Vitro Diagnostic Device Evaluati 510K Page 15 of 263
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...