The Auradorm sleep appliance is a dentist prescribed mandibular repositioning device worn during sleep to reduce the incidence of snoring and reduce the effects of mild to moderate obstructive sleep apnea for patients 18 years or older.
Device Story
Auradorm is a custom-fit, one-piece oral appliance for reducing snoring and mild-to-moderate obstructive sleep apnea. Prescribed by dentists and fabricated from dental acrylic/resin, stainless steel ball clasps, and orthodontic stainless steel braid. Device covers occlusal/buccal aspects of lower arch and posterior maxillary teeth; anterior opening allows mouth breathing. Dentist uses bite registration to determine mandibular protrusion; device holds mandible forward and vertically open during sleep to increase pharyngeal space and improve air exchange. Used at home or in sleep labs; patient self-inserts/removes. Benefits include reduced snoring and improved airway patency. Clinical decision-making supported by pre-treatment dental/TMJ exams and sleep studies.
Clinical Evidence
No clinical data provided. Substantial equivalence is based on design, material composition, and functional similarity to legally marketed predicate devices. Safety is addressed through design features (e.g., anterior opening to prevent breathing obstruction, custom fit to avoid soft tissue impingement) and clinical recommendations for pre-treatment dental/TMJ evaluation and follow-up sleep studies.
Technological Characteristics
Custom-fit, one-piece intraoral appliance. Materials: Methyl methacrylate acrylic or dental resin, 304/316 stainless steel ball clasps, and orthodontic stainless steel braid. Non-sterile. Mechanical principle: Mandibular repositioning (protrusion and vertical opening). Designed with anterior opening for breathing and lingual material reduction for tongue space.
Indications for Use
Indicated for patients 18 years or older with mild to moderate obstructive sleep apnea or snoring. Contraindicated for patients not evaluated by a physician for sleep disorders or those with specific TMJ risks identified by a dentist.
Regulatory Classification
Identification
Intraoral devices for snoring and intraoral devices for snoring and obstructive sleep apnea are devices that are worn during sleep to reduce the incidence of snoring and to treat obstructive sleep apnea. The devices are designed to increase the patency of the airway and to decrease air turbulence and airway obstruction. The classification includes palatal lifting devices, tongue retaining devices, and mandibular repositioning devices.
Special Controls
*Classification.* Class II (special controls). The special control for these devices is the FDA guidance document entitled “Class II Special Controls Guidance Document: Intraoral Devices for Snoring and/or Obstructive Sleep Apnea; Guidance for Industry and FDA.”
{0}------------------------------------------------
Image /page/0/Picture/0 description: The image shows a handwritten sequence of characters and numbers. The sequence starts with the letter 'K', followed by the number '10', then '11', and ends with what appears to be the number '33', written in a stylized or cursive manner. The writing is in black ink against a white background, and the characters are spaced apart.
MAY 1 2 2011
# · SLEEPWRIGHT 27 TIMBERWICK RD. SANTA FE, NM 87508 Phone (505)989-7866 FAX (505) 983-8395
t
# 510-(K) SUMMARY
This summary of 510(K) safety and effectiveness information is being submitted in accordance with the requirements of 21 CFR 807.92.
SUBMITTER INFORMATION: Cynthia Wright CDT 27 Timberwick Rd Santa Fe, New Mexico 87508
Date Summary Prepared: March 21, 2011
- Cynthia Wright CDT Contact Person: 27 Timberwick Rd Santa Fe, NM 87508 505-989-7866 Cell 505-204-8658 e-mail cynthia@cwrightn.com Dr. Jeff S. Luffey 505-294-4700 Cell 505-366-3178 e-mail jeffluffey@yahoo.com
Device Name: Auradorm Device Classification Name: Anti-snoring (21CFR 872.5570) Manufacturer: SLEEPWRIGHT Panel: Dental Product Code: LRK Classification: Class II 510K # K101155/
### Devices for Which Substantial Equivalence is Claimed:
Lamberg Sleep Well Device K062333 Snore Guard K103004 Acrylic Herbst Appliance K083209
### Device Description:
The Auradorm Sleep Appliance is a one piece oral appliance used for reducing snoring and the effects of mild to moderate obstructive sleep apnea. The one piece upper and lower tooth engaging appliance covers the occlusal and buccal aspects of the entire lower arch teeth and the occlusal and buccal aspects of the posterior maxillary teeth to include the
{1}------------------------------------------------
maxillary canines. The maxillary central and lateral incisors do not touch the appliance. The device does not rest or impinge on soft tissue. The oral appliance is prescribed by a dentist and custom fit to the patient's mouth in the dental clinic. The oral appliance is made of FDA approved dental acrylic or resin, stainless steel ball clasps and orthodontic stainless steel braid embedded in the acrylic for strengthening purposes. The appliance is designed to limit the amount of material on the lingual aspect of the teeth and still maintain the anti-snoring functionality based on the predicate devices. The appliance has an anterior opening to prevent restriction of mouth breathing and is reinforced with orthodontic stainless steel metal braid embedded in the acrylic. Ball clasps are situated in the appliance to provide upper and lower tooth retention and adjustability for patient comfort.
The prescribing dentist determines the exact repositioning of the lower jaw via a bite registration obtained from the patient in the clinic. The dentist is able to fine tune the jaw position clinically by trying different bite registrations. The final bite registration is held in the patient's mouth to discern jaw comfort and ability to breath comfortably.
The functional relationship built into the appliance positions the mandible forward and open more vertically from it's normal location which causes a protrusion of the mandible in relation to the maxilla. This forward repositioning, which is temporary while the appliance is being used increases pharyngeal space which assists the patient with improved air exchange.
#### Intended Use of the Device:
The Auradorm Sleep Appliance is a dentist prescribed mandibular repositioning device worn during sleep to reduce the incidence of snoring and reduce the effects of mild to moderate obstructive sleep apnea for patients 18 years or older.
#### Comparison to Predicate Device:
| DEVICE: | AURADORM | Lamberg Sleep Well Device<br>K062333 | Snore Guard<br>K103004 | Acrylic Splint Herbst<br>K083209 |
|-----------------------------------------|----------|--------------------------------------|------------------------|----------------------------------|
| Attribute: | | | | |
| Overnight use | Yes | Yes | Yes | Yes |
| Single patient multi-use | Yes | Yes | Yes | Yes |
| Easily removed from the mouth | Yes | Yes | Yes | Yes |
| Can be adjusted or refit | Yes | Yes | Yes | Yes |
| Cleaned and inspected daily | Yes | Yes | Yes | Yes |
| Placed in mouth each night | Yes | Yes | Yes | Yes |
| Use at home or sleep lab | Yes | Yes | Yes | Yes |
| Prevents grinding of teeth | Yes | Yes | Yes | Yes |
| Dentist prescribed device | Yes | Yes | Yes | Yes |
| FEATURES: | | | | |
| ACTION: | | | | |
| Mandibular repositioning | Yes | Yes | Yes | Yes |
| | | | | |
| DESIGN: | | | | |
| Custom fit for each patient | Yes | Yes | Yes | Yes |
| Acrylic fits over upper and lower teeth | Yes | Yes | Yes | Yes |
{2}------------------------------------------------
| Materials: | | | | |
|-----------------------------------------------------|-----|-----|-----|-----|
| Non-sterile Dental Acrylic<br>(Methyl methacrylate) | Yes | Yes | Yes | Yes |
| Dental Resin | Yes | No | No | Yes |
| Metal Ball Clasps<br>(Stainless Steel) | Yes | Yes | No | Yes |
| Orthodontic metal braid<br>(Stainless Steel) | Yes | No | No | No |
## Technological Characteristics Summary of Auradorm:
- 1. An acrylic or resin based oral appliance
- 2. Jaw Repositioning
- 3. Single patient custom fit
- 4. Dentist prescribed intra-oral device
- 5. Environment home/sleep laboratory
- 6. Removable
- 7. Non- Sterile
- 8. Intended to reduce snoring and mild to moderate obstructive sleep apnea
- 9. Custom fit to mandibular teeth and engages the maxillary teeth
## Safety and Efficacy:
The Auradorm Sleep Appliance is based on the principles of repositioning the mandible to open the airway which is similar to many marketed anti-snoring devices. This appliance is made of FDA approved dental acrylic, ball clasps and embedded orthodontic stainless steel braid.
Risks to Health: Oral appliances can cause gingival soreness, movement of teeth, periodontal issues, temporomandibular joint or muscle pain, may obstruct the airway or change results of a polysomnogram. The auradorm sleep appliance has addressed these risks through specific design features as noted below:
Soft tissue soreness: The appliance is custom fit to the patient's natural dentition and does not rest on or touch gingival tissue.
TMD Concerns: The Auradorm accomplishes the goal of increasing the airway by repositioning the lower jaw down and forward. It is recognized by the dental community that this altered jaw relationship can also affect the temporomandibular joints. The prescribing dentist should perform a TMJ examination prior to using the Auradorm to make sure the patientis not predisposed to TMD risks that may be aggravated by using the appliance. Some patients do report sensations in the TMJ area in the early stages of appliance wear, but these are usually transitory with continued use. The prescribing dentist can also slightly alter the jaw position by adjusting the acrylic of the appliance. If discomfort persists a new bite registration can be taken to fabricate a new appliance. Should TMJ pain persist, the patient can decide with their dentist to stop discontinue treatment with this modality.
Obstruction of Oral Breathing: The Auradorm will not obstruct oral breathing due to the anterior opening created in the design of the appliance. The Auradorm also increases the airway by limiting the amount of acrylic on the lingual aspect of the teeth. This allows more tongue space in the anterior part of the oral cavity and increases the pharyngeal space which is the goal of all anterior repositioning devices. It is commonly accepted in the dental community that anterior positioning of the tongue and mandible increases pharyngeal space
{3}------------------------------------------------
that improves air exchange.
Loosening or flaring of teeth: The auradorm is fabricated to minimize tooth movement due to occlusal coverage of all teeth except the maxillary central and lateral incisors. The full posterior occlusal coverage of teeth reduces local forces and pressure on inidvidual teeth or segments of teeth like lower anteriors . The dentist is also able to easily control pressure on teeth by adjusting the acrylic which can reduce the forces directed to individual teeth and supporting alveolar structures.
Polysomnogram Results: Before a dentist prescribes an Auradorm, the patient must receive a complete dental examination, a complete TMJ evaluation, and a complete medical examination which includes a sleep study by a certified sleep physician. The prescribing dentist should consider the medical history of the patients, including history of asthma, breathing or respiratory disorders, or other relevant health problems and should refer the patient to the appropriate health care provider before prescribing the device. Follow-up sleep studies with the patient using the device is highly recommended to ensure that the desired effects are achieved.
Material Composition: The Auradorm is fabricated from known dental materials used for decades throughout the industry.
The Auradorm contains or uses the following materials:
Stainless Steel (304 or 316) - Stainless steel is a commonly accepted material for dental products. All Auradorm metal components are manufactured with 304 or 316 Stainless Steel. Dental Acrylic - The Auradorm is typically made with a methyl methacrylate for the acrylic portions of the appliance. Methyl methacrylate has been used in the dental industry for well over 50 years and does not pose any known health hazards to the patient in its polymerized form. The dentist may also request the appliance to be fabricated with FDA approved dental resin.
Intended Use Statement: The Auradorm is a dentist prescribed sleep appliance which is worn during sleep by individuals 18 years or older, who want to reduce the incidence of snoring or mild to moderate obstructive sleep apnea.
Summary Report: The Auradorm is substantially equivalent to the predicates because the device is a one piece maxillary and mandibular teeth engaging oral appliance made of FDA approved dental acrylic or resin, and commonly used orthodontic materials. This device has the same intended uses as the Snore Guard, Lamberg Sleep Well Device, and Acrylic Splint Herbst appliance, and is constructed with the same materials currently used by dentists to make anti-bruxing or night quards. The minor differences in the Auradorm's technological characteristics do not raise any new questions of safety or effectiveness, thus the Auradorm is substantially equivalent to the referenced predicate devices.
{4}------------------------------------------------
Image /page/4/Picture/1 description: The image shows the seal of the Department of Health & Human Services (HHS) of the United States. The seal features a stylized eagle with its wings spread, symbolizing protection and service. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged in a circular pattern around the eagle.
Food and Drug Administration 10903 New Hampshire Avenue Document Control Room-WO66-G609 Silver Spring, MD 20993-0002
MAY 1 2 2011
Ms. Cynthia Wright Auradorm Sleepwright 27 Timberwick Road Santa Fe. New Mexico 87508
Re: K101155
Trade/Device Name: Auradorm (Neuromuscular Sleep) Regulation Number: 21 CFR 872.5570 Regulation Name: Intraoral Device for Snoring and Intraoral Devices for Snoring and Obstructive Sleep Apnea Regulatory Class: II Product Code: LRK
Dated: March 21, 2011 Received: March 31, 2011
Dear Ms. Wright:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
{5}------------------------------------------------
Page 2- Ms. Wright
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please go to http://www.fda.gov/AboutFDA/CentersOffices/CDRH/CDRHOffices /ucm115809.htm for the Center for Devices and Radiological Health's (CDRH's) Office of Compliance. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), pleasing the http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default.htm.
Sincerely vours.
for
Anthony D. Watson, B.S., M.S., M.B.A. Director
Division of Anesthesiology, General Hospital, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{6}------------------------------------------------
SLEEPWRIGHT 27 TIMBERWICK RD. SANTA FE, NM 87508 Phone (505)989-7866 FAX (505) 983-8395
#### INDICATIONS FOR USE STATEMENT
Revision Date: February 27, 2011
SUBMITTER INFORMATION: Cynthia Wright CDT 505-989-7866 27 Timberwick Rd Santa Fe, New Mexico 87508
Indications for Use
Common Name: Anti-snoring appliance Device Classification Name: Anti-snoring (21CFR 872.5570) Manufacturer: SLEEPWRIGHT Panel: Dental Product Code: LRK Classification: Class II 510K # K101155/ >
The Auradorm sleep appliance is a dentist prescribed mandibular repositioning device worn during sleep to reduce
the incidence of snoring and reduce the effects of mild to moderate obstructive sleep apnea for palients 18 years or
older.
Prescription Use _YES AND/OR Over-The-Counter Use __ NO (21 CFR 801 Subpart C) (Part 21 CFR 801 Subpart D)
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Susan Luar
(Division Sign-Off) Division of Anesthesiology, General Hospital nfection Control, Dental Devic
510(k)
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Guidance alerts
New and changed FDA guidance documents, emailed as a daily digest.
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the ? button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only Software as a Medical Device, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (Software as a Medical Device), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.