NDS SURGICAL IMAGING, LLC FOR THE ZEROWIRE DUO WIRELESS HD VIDEO TRANSFER SYSTEM, MODEL WU-WX-WY (WHERE U=R OR T, W=P, X

K100195 · Nds Surgical Imaging · GCJ · Apr 21, 2010 · Gastroenterology, Urology

Device Facts

Record IDK100195
Device NameNDS SURGICAL IMAGING, LLC FOR THE ZEROWIRE DUO WIRELESS HD VIDEO TRANSFER SYSTEM, MODEL WU-WX-WY (WHERE U=R OR T, W=P, X
ApplicantNds Surgical Imaging
Product CodeGCJ · Gastroenterology, Urology
Decision DateApr 21, 2010
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 876.1500
Device ClassClass 2
Attributes3rd-Party Reviewed

Indications for Use

The NDSsi ZeroWire Duo Wireless HD Video Transfer System is a paired transmitter and receiver, intended for delivery of video signals over a radio-frequency link to a video display during endoscopic and general surgical procedures. The ZeroWire wireless device is a non-sterile reusable device not intended for use in the sterile field. It is intended for use by qualified physicians having complete knowledge of these surgical procedures.

Device Story

ZeroWire Duo is a wireless transmitter/receiver pair for high-definition video transmission in ORs; inputs digital video signals from surgical cameras; transmits via UWB (Ultra-Wideband) radio frequency link to surgical monitors; eliminates video cables; reduces tripping hazards; simplifies OR setup via proprietary memory-enabled pairing. Operated by qualified physicians/medical professionals; non-sterile; not for use in sterile field. Provides <1 frame latency; uses industry-standard data encryption for security. Benefits include improved clinical efficiency and safety by removing cable clutter and cleaning requirements.

Clinical Evidence

No clinical data provided. Substantial equivalence supported by non-clinical bench testing and surgical-setting performance testing.

Technological Characteristics

Wireless video transfer system using UWB (Ultra-Wideband) frequency spectrum. Features proprietary memory-enabled pairing. Supports full high-definition video with <1 frame latency. Employs industry-standard data encryption. Conforms to EN 60601-1 (medical safety) and EN 60601-1-2 (EMC) standards, and FCC Part 15. Non-sterile, reusable device.

Indications for Use

Indicated for delivery of video signals during endoscopic and general surgical procedures. Intended for use by qualified physicians. Not for use in the sterile field.

Regulatory Classification

Identification

An endoscope and accessories is a device used to provide access, illumination, and allow observation or manipulation of body cavities, hollow organs, and canals. The device consists of various rigid or flexible instruments that are inserted into body spaces and may include an optical system for conveying an image to the user's eye and their accessories may assist in gaining access or increase the versatility and augment the capabilities of the devices. Examples of devices that are within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes, flexible or rigid choledochoscopes, colonoscopes, diagnostic cystoscopes, cystourethroscopes, enteroscopes, esophagogastroduodenoscopes, rigid esophagoscopes, fiberoptic illuminators for endoscopes, incandescent endoscope lamps, biliary pancreatoscopes, proctoscopes, resectoscopes, nephroscopes, sigmoidoscopes, ureteroscopes, urethroscopes, endomagnetic retrievers, cytology brushes for endoscopes, and lubricating jelly for transurethral surgical instruments. This section does not apply to endoscopes that have specialized uses in other medical specialty areas and that are covered by classification regulations in other parts of the device classification regulations.

Special Controls

*Classification* —(1)*Class II (special controls).* The device, when it is an endoscope disinfectant basin, which consists solely of a container that holds disinfectant and endoscopes and accessories; an endoscopic magnetic retriever intended for single use; sterile scissors for cystoscope intended for single use; a disposable, non-powered endoscopic grasping/cutting instrument intended for single use; a diagnostic incandescent light source; a fiberoptic photographic light source; a routine fiberoptic light source; an endoscopic sponge carrier; a xenon arc endoscope light source; an endoscope transformer; an LED light source; or a gastroenterology-urology endoscopic guidewire, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.(2) Class I for the photographic accessories for endoscope, miscellaneous bulb adapter for endoscope, binocular attachment for endoscope, eyepiece attachment for prescription lens, teaching attachment, inflation bulb, measuring device for panendoscope, photographic equipment for physiologic function monitor, special lens instrument for endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and cleaning brush for endoscope. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807of this chapter, subject to the limitations in § 876.9.

In combination with the general controls of the FD&C Act, the integrated operating table-electromechanical surgical system is subject to the following special controls: 1. (1) Premarket clinical performance testing, or a combination of premarket clinical performance testing and postmarket surveillance (in accordance with special control (2)), must include the following: 1. (i) Objective performance measures (e.g., rate and number of conversions to other surgical modalities, rate of device related adverse events (including tissue injury, hematoma, and increased blood loss), and their severity, cause, and outcomes) must be reported with relevant descriptive comparator performance measures. 2. (ii) The data must demonstrate the performance of the device for providing accurate and precise control of attached surgical instruments in range of clinical conditions relevant to the device's intended use. 3. (iii) The test dataset must include data collected from a patient population representative of the intended patient population under anticipated conditions of use. 2. (2) Data obtained from postmarket surveillance must demonstrate, in consideration of the premarket data obtained in accordance with special control (1), that the device performs in accordance with special control (1), unless FDA determines, based on the totality of the premarket data, that data from postmarket surveillance is not required to demonstrate that the device performs as intended. Such postmarket surveillance must be conducted per a protocol determined appropriate by FDA to demonstrate that the device performs as intended (in consideration of the premarket data obtained in accordance with special control (1)), and must include initiation, enrollment, and reporting requirements to ensure timely periodic updates to FDA on post-market surveillance progress and outcomes. 3. (3) Animal performance testing must evaluate the extent of port site trauma due to repositioning of table during surgical procedures when utilizing robotic minimally invasive and laparoscopic approaches 4. (4) The device manufacturer must develop, and update as necessary, a device-specific use training program that ensures proper device setup/use/shutdown, accurate control of instruments to perform the intended surgical procedures, troubleshooting and handling during unexpected events or emergencies, and safe practices to mitigate use error. 5. (5) The device manufacturer may only distribute the device to facilities that implement and maintain the device-specific use training program and ensure that users of the device have completed the device-specific use training program. (6) Human factors assessment must demonstrate that the user can correctly use the device system across all intended use environments with the provided instructions and training materials, including patient access during normal operating conditions and emergency situations, and effects arising from the integrated nature of the operating table and robotic surgical arms. (7) Labeling must include: (i) A detailed summary of clinical performance testing conducted with the device, including study population, results, adverse events, and comparisons to any comparator groups identified; (ii) A statement in the labeling that the safety and effectiveness for the representative specific procedures was based on evaluation of the device as a surgical tool and did not include evaluation of outcomes related to the treatment of the patient's underlying disease or condition, unless FDA determines that it can be removed or modified based on clinical performance data submitted to FDA; (iii) Identification of compatible devices; (iv) The list of surgical procedures for which the device has been determined to be safe with clinical justification; (v) Reprocessing instructions for reusable components; (vi) A shelf life for any sterile components; (vii) A description of the device-specific use training program; (viii) A statement that the device is only for distribution to facilities that implement and maintain the device-specific use training program and ensure that users of the device have completed the device-specific use training program; and (ix) A summary of any completed postmarket surveillance data collected as required by special control (2), including updated labeling to accurately reflect outcomes observed in postmarket surveillance. (8) Non-clinical performance testing must demonstrate that the device performs as intended under anticipated conditions of use and must include: (i) Device motion accuracy and repeatability; (ii) System testing; (iii) Instrument reliability; (iv) Crosstalk; (v) Table motion control; (vi) Thermal effects on tissue; (vii) User-device interface performance; (viii) Workspace access testing; and (ix) Performance testing with compatible devices. (9) Software verification, validation, and hazard analysis must be performed. (10) Electromagnetic compatibility and electrical, thermal, and mechanical safety testing must be performed. (11) Performance data must demonstrate the sterility of all patient-contacting device components. (12) Performance data must support the shelf life of the device components provided sterile by demonstrating continued sterility and package integrity over the labeled shelf life. (13) Performance data must validate the reprocessing instructions for the reusable components of the device. (14) Performance data must demonstrate that all patient-contacting components of the device are biocompatible. (15) Performance data must demonstrate that all patient-contacting components of the device are non-pyrogenic. (16) The device manufacturer must submit a report to the FDA annually on the anniversary of initial marketing authorization for the device, until such time as FDA may terminate such reporting, which comprises the following information: (i) Cumulative summary, by year, of complaints and adverse events since date of initial marketing authorization; and (ii) Identification and rationale for changes made to the device, labeling, or device specific use training program, which did not require submission of a premarket notification during the reporting period.

Predicate Devices

Submission Summary (Full Text)

{1}------------------------------------------------ K.100195. Page 1 of 2 ## 510(k) SUMMARY ## APR 2 1 2010 A. Manufacturer: NDS Surgical Imaging, LLC 5750 Heilyer Avenue San Jose, CA 95138 USA B. Submitted By: Jim Leng Regulatory Engineer NDS Surgical Imaging, LLC C. Date of Preparation: November 2, 2009 April 15, 2010 revision > Tel: 408-776-0085 408-776-9878 Fax: E. Classification: Endoscope and Accessories GCJ F. Common Name: UWB Wireless Device ZeroWire Duo Wireless HD Video Transfer System H. Classification Number: 21 CFR 876.1500 - I. Product Code: J. Substantial Equivalence: D. Contact Information: G. Proprietary Name: Stryker Vision Elect Wireless High Definition Television (Stryker VE VHDTV) / K081995 Both the Stryker device and the NDS device contain a wireless, radio frequency transmitter that receives a digital video signal from a surgical camera. Both systems incorporate a wireless, radio frequency receiver that is exclusively linked to but only to the aforementioned transmitter. The wireless receiver of both systems delivers the received video signal to a suitable surgical monitor for use by qualified medical professionals. Both systems conform to non-clinical tests including the medical safety and EMC standards defined by EN 60601-1 and EN 60601-1-2. Both systems require a single transmitter to be linked to an individual receiver. As wireless devices, both systems conform to relevant FCC Part 15 standards. Both systems provide video data security by employing industry-standard data encryption techniques. ® RADIANCE Image /page/0/Picture/18 description: The image shows the word "DOME" in bold, black letters. Above the word is a black semi-circle, which appears to be the top half of a dome shape. There is a horizontal line below the word "DOME". The background is white. {2}------------------------------------------------ K100195 Page 2 of 2 The singular difference between the Stryker system and the NDS system is that in the Stryker system the receiver is embedded in the monitor, whereas in the NDS system, the receiver is a separate item which can be electrically connected by means of an appropriate cable to a suitable surgical monitor. The ZeroWire® wireless device is a wireless transmitter K. Device Description: and receiver pair which allows delivery of a video signal over a radio frequency link to a video display such as Radiance and EndoVue LCD surgical monitors. The NDSsi ZeroWire Duo Wireless HD Video Transfer System L. Intended Use: is a paired transmitter and receiver, intended for delivery of video signals over a radio-frequency link to a video display during endoscopic and general surgical procedures. The Zero Wire wireless device is a non-sterile reusable device not intended for use in the sterile field. It is intended for use by qualified physicians having complete knowledge of these surgical procedures. M. Technological Characteristics: The ZeroWire Duo wireless device is a wireless video transfer solution for minimally invasive surgery and interventional procedures. It delivers full high-definition video with less than 1 frame latency. By utilizing the reserved UWB frequency spectrum, ZeroWire provides a wireless video link that is resistant to interference from other devices. ZeroWire improves clinical efficiency and safety in the OR by eliminating the need for video cables their cleaning, frequent replacement, and potential to be a tripping hazard. The proprietary memory-enabled pairing system makes installation quick and easy. N. Clinical information: Clinical data is not needed for this type of wireless device 510(k) submission. However, this submission includes surgical-setting test results to demonstrate the equivalence of the ZeroWire device to the predicate Stryker device. Based on non-clinical tests as well as surgical-setting tests, O. Conclusion: the ZeroWire wireless device provides performance, safety, and effectiveness that is equivalent to the predicate Stryker Vision Elect Wireless High Definition Television (Stryker VE VHDTV) / K081995. {3}------------------------------------------------ Image /page/2/Picture/1 description: The image shows the logo for the U.S. Department of Health and Human Services. The logo features a stylized eagle or bird-like symbol with three curved lines forming its body and wings. The logo is surrounded by a circular border containing the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" in capital letters. Food and Drug Administration 10903 New Hampshire Avenue Document Control Room -WO66-G609 Silver Spring, MD 20993-0002 APR 21 2010 NDS Surgical Imaging % TUV Rheinland of North America, Inc. Tamas Borsai Manager, Medical Division 12 Commerce Road Newton, Connecticut 06470 Re: K100195 Trade/Device Name: ZeroWire Duo Wireless HD Video Transfer System Regulation Number: 21 CFR 876.1500 Regulation Name: Endoscope and accessories Regulatory Class: Class II Product Code: GCJ Dated: April 02, 2010 Received: April 06, 2010 Dear Tamas Borsai: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you; however, that device labeling must be truthful and not misleading. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must {4}------------------------------------------------ Page 2 - Tamas Borsai comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please go to http://www.fda.gov/AboutFDA/CentersOffices/CDRH/CDRHOffices/ucm115809.htm for the Center for Devices and Radiological Health's (CDRH's) Office of Compliance. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance. You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm. .fda.gov/MedicalDevices/ResourcestorYou/Industry/default.htm Sincerely yours, Mark A. Milliken Mark N. Melkerson Director Division of Surgical, Orthopedic And Restorative Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {5}------------------------------------------------ Image /page/4/Picture/0 description: The image shows the logo for NDS Surgical Imaging. The logo consists of a grid of squares on the left, followed by the letters NDS in large, bold font. Below the letters is the text "SURGICAL · IMAGING" in a smaller font. The logo is black and white. i00195 ## Indications for Use Statement 510 (k) Number (if Known): Device Name: ZeroWire Duo Wireless HD Video Transfer System Indications for Use: The NDSsi ZeroWire Duo Wireless HD Video Transfer System is a paired transmitter and receiver, intended for delivery of video signals over a radio-frequency link to a video display during endoscopic and general surgical procedures. The ZeroWire wireless device is a non-sterile reusable device not intended for use in the sterile field. It is intended for use by qualified physicians having complete knowledge of these surgical procedures. Prescription Use (Part 21 CFR 801 Subpart D) AND/OR Over-the-Counter Use (21 CFR 801 Subpart C) (Please DO NOT WRITE BELOW THIE LINE - CONTINUE ON ANOTHER PAGE IF NEEDED) Phil R. Concurrence of CDRH, Office of Device Evaluation (ODE) Division Sign-Division of Surgical, Orthopedic, and Restorative Devices 510(k) Number K100195
Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...