Proxcelan™ (Gesium-131) Implant Devices, Model PL-5 – Cs-131 Preloaded Braided Strands, containing cesium-131 brachytherapy seeds are indicated for the treatment of malignant disease (e.g. head and neck, brain, breast, lung, prostate, eye, etc.) and may be used in surface, interstitial, and intracavity applications for tumors with known radiosensitivity. These devices may be used as a rimary treatment or in conjunction with other treatment modalities, such as external beam radiation therapy, chemotherapy or as a treatment modalites, after excision of primory tumore after excision of primary tumors.
Device Story
Proxcelan Model PL-5 consists of Cesium-131 brachytherapy seeds preloaded into bioabsorbable braided sleeves (strands). Seeds are arranged in precise patterns per physician/physicist treatment plans to maintain specific spacing. Strands may be woven into bioabsorbable mesh for implantation. Device is a single-use, prescription-only implant. Used by physicians to deliver localized nuclear radiation to malignant tumors. Braided design provides flexibility compared to rigid hollow tubular strands. Benefits include precise, customizable seed positioning within body cavities or tissues to treat radiosensitive tumors.
Clinical Evidence
Bench testing only. No clinical data provided. Safety and effectiveness are supported by adherence to product design specifications, including leak testing for external contamination and verification of apparent activity.
Indicated for patients with malignant disease (e.g., head, neck, brain, breast, lung, prostate, eye) with known radiosensitivity. Used for surface, interstitial, or intracavity applications as primary treatment or in conjunction with external beam radiation, chemotherapy, or post-excision.
Regulatory Classification
Identification
A radionuclide brachytherapy source is a device that consists of a radionuclide which may be enclosed in a sealed container made of gold, titanium, stainless steel, or platinum and intended for medical purposes to be placed onto a body surface or into a body cavity or tissue as a source of nuclear radiation for therapy.
Special Controls
*Classification.* Class II (special controls). A prostate seeding kit intended for use with a radionuclide brachytherapy source only is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 892.9.
{0}------------------------------------------------
Image /page/0/Picture/0 description: The image shows the logo for IsoRay Medical. The logo features an atom symbol to the left of the company name. The word "MEDICAL" is written in smaller letters below "IsoRay".
1092136
# AUG 0 7 2009
#### 3.0 Section C: 510(k) Summary Required by 21 CFR § 807.92
- 3.1 Submitter: IsoRay Medical, Inc.
- 3.2 Address: 350 Hills Street, Suite 106 Richland, WA 99354-5411
- 3.3 Telephone and Fax Numbers: 509-375-1202 (Fax) 509-375-3473
- 3.4 Contact Person: Fredric Swindler fswindler@isoray.com
- Date of preparation of this Summary: 07/10/09 3.5
- Device Name, Regulatory and Classification Information: 3.6
- Trade Name: Proxcelan™ (Cesium-131) Implant Devices, Model PL-5 --3.6.1 Cs-131 Preloaded Braided Strands
- 3.6.2 Common Name: Preloaded Brachytherapy Seeds
- Classification Name: Radionuclide Brachytherapy Source (Per 21CFR 3.7 8892.5730)
- Marketed device to which equivalence is claimed: The Proxcelan (Cesium-3.8 131) Implant Devices, Model PL-5 – Cs-131 Preloaded Braided Strands that are the subject of this submission are substantially equivalent to the IsoRay Proxcelan™ (Cesium-131) Implant Devices as described in 510(k) No. K062384 (SE 11/09/2006).
- Product Description: The Proxcelan (Cesium-131) Implant Devices, Model PL-5 3.9 – Cs-131 Preloaded Braided Strands are single use, prescription devices, will consisting of IsoRay Model CS-1 Brachytherapy Seeds that are preloaded into into a body series of the Implant Devices are designed to be preloaded into into a body cavity or tissue as a source of nuclear radiation for the treatment of malignant disease. The PL-5 – Cs-131 Preloaded Braided Braided Strands consist of a series of Proxcelan (Cesium-131) Brachytherapy Seeds held in place within a bioabsorbable braided sleeve (or strand). The seeds are arranged in a precise pattern in order to maintain the exact locations and separation distances between the seeds as indicated on a treatment plan prepared by the physician or medical physicist for an individual patient. If required by the treatment plan, the braided strands containing the brachytherapy seeds may be woven into a bioabsorbable mesh supplied as a kit component for implant. A (non-patient contact) needle may also be provided either attached or unattached to the braided strand to attach it to the mesh.
{1}------------------------------------------------
Image /page/1/Picture/0 description: The image shows the logo for IsoRay Medical. The logo features a stylized atom symbol on the left, followed by the text "IsoRay" in a bold, sans-serif font. Below "IsoRay" is the word "MEDICAL" in a smaller, sans-serif font. The overall design is simple and professional.
- Statement of intended use compared to the currently marketed predicate 3.10 device: Proxcelan (Cesium-131) Implant Devices, Model PL-5 - Cs-131 Preloaded Braided Strands are single use prescription devices that are intended for medical purposes to be placed onto a body surface or into a body cavity or tissue as a source of nuclear radiation for therapy. This is identical to the legally marketed predicate devices, the IsoRay Proxcelan (Cesium-131) Implant Devices as described in 510(k) No. K062384 (SE 11/09/2006).
- Statement of Technological Characteristics: The technical characteristics 3.11 consist of cesium-131 brachytherapy seeds that are preloaded into braided bioabsorbable sleeves (strands). All materials used in the construction of the Proxcelan (Cesium-131) Implant Devices are biocompatible and currently used in similar marketed devices that are in wide clinical application. The difference between the currently marketed Proxcelan (Cesium-131) Implant Devices and the proposed modification is the addition of a preloaded flexible braided stand instead of the current rigid hollow tubular strand.
- Safety and Effectiveness: To ensure that the devices are safe and effective, all 3.12 finished products are tested and must meet all required release specifications before distribution. The testing required for release specifications
tech to the county of the testing required for release includes, but is not limited to leak testing for external contamination, apparent activity, but is not himmed labeling. The required testing is defined by written and approved procedures that conform to the product design specifications. The testing for Proxcelan (Cesium-131) Implant Devices, Model PL-5 – Cs-131 Preloaded Braided Strands is detailed in the Device Master Record.
{2}------------------------------------------------
Image /page/2/Picture/0 description: The image shows a partial logo of the Department of Health and Human Services. The logo features a stylized human figure with outstretched arms, and the text "DEPA" is visible to the right of the figure. The image is black and white and appears to be a close-up of the logo.
### DEPARTMENT OF HEALTH & HUMAN SERVICES
Public Health Service
Food and Drug Administration · 10903 New Hampshire Avenue Document Control Room - WO66-G609 Silver Spring, MD 20993-0002
Mr. Fredric G. Swindler Vice President Regulatory Affairs and Quality Assurance IsoRay Medical, Inc. 350 Hills St., Suite 106 RICHLAND WA 99354-5411
AUG 0 7 2009
Re: K092136
Trade/Device Name: Proxcelan™ (Cesium-131) Implant Devices, Model PL-5 - Cs-131 Preloaded Braided Strands Regulation Number: 21 CFR 892.5730 Regulation Name: Radionuclide brachytherapy source Regulatory Class: II Product Code: KXK Dated: July 10, 2009 Received: July 15, 2009
Dear Mr. Swindler:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting of medical
{3}------------------------------------------------
device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (OS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please go to http://www.fda.gov/AboutFDA/CentersOffices/CDRH/CDRHQffices/ucm115809.htm for the Center for Devices and Radiological Health's (CDRH's) Office of Compliance. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/cdrh/mdr/ for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (240) 276-3150 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html.
Sincerely yours,
Janine M. Morris
Janine M. Morris Acting Director, Division of Reproductive, Abdominal, and Radiological Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{4}------------------------------------------------
#### 2.0 Section B
## Indications for Use
510(k) Number:
f092136
Device Name: Proxcelan™ (Cesium-131) Implant Devices, Model PL-5 – Cs-131 Preloaded Braided Strands
Indications for Use:
Proxcelan™ (Gesium-131) Implant Devices, Model PL-5 – Cs-131 Preloaded Braided Strands, containing cesium-131 brachytherapy seeds are indicated for the treatment of malignant disease (e.g. head and neck, brain, breast, lung, prostate, eye, etc.) and may be used in surface, interstitial, and intracavity applications for tumors with known radiosensitivity. These devices may be used as a rimary treatment or in conjunction with other treatment modalities, such as external beam radiation therapy, chemotherapy or as a treatment modalites,
after excision of primory tumore after excision of primary tumors.
Prescription Use × (Per 21 CFR § 801.109)
OR
Over-The-Counter Use
(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Hulut Leun
(Division Sign-Off) Division of Reproductive, Abdominal. and Radiological Devices 10(k) Number
Page 4 of 32
Page 1 of 1
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Guidance alerts
New and changed FDA guidance documents, emailed as a daily digest.
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the ? button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only Software as a Medical Device, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (Software as a Medical Device), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.