XTAG RESPIRATORY VIRAL PANEL, MODELS I019A0110, I019C011, I019D0112, I019E0113, S019-0116

K091667 · Luminex Molecular Diagnostics, Inc. · OCC · Jun 25, 2009 · Microbiology

Device Facts

Record IDK091667
Device NameXTAG RESPIRATORY VIRAL PANEL, MODELS I019A0110, I019C011, I019D0112, I019E0113, S019-0116
ApplicantLuminex Molecular Diagnostics, Inc.
Product CodeOCC · Microbiology
Decision DateJun 25, 2009
DecisionSESE
Submission TypeSpecial
Regulation21 CFR 866.3980
Device ClassClass 2
AttributesReal-World Evidence

Real-World Evidence

SubmissionDeviceSponsorRWD SourcesRWE Use SummaryKey Tags
K091667 · Jun 25, 2009XTAG RESPIRATORY VIRAL PANEL, MODELS I019A0110, I019C011, I019D0112, I019E0113, S019-0116Luminex Molecular Diagnostics, Inc.Clinical nasopharyngeal swab samples from routine testing/surveillance; Published clinical literature (Ginocchio & George, 2009; Ginocchio et al., 2009)Retrospective analysis of clinical specimens collected during the 2009 H1N1 outbreak to evaluate the performance of the xTAG RVP assay in detecting 2009 H1N1 influenza virus.2009 H1N1 influenza; Retrospective clinical samples; Surveillance data

Clinical Evidence

Study DesignPopulationComparatorKey Endpoints
Ginocchio & George (2009); Retrospective analysis of clinical samples; Study Period: 2009 H1N1 outbreakPatients with suspected respiratory infection during 2009 H1N1 outbreak; Sample Size: 1,382 total samples; 375 tested with xTAG RVP; Number of Sites: 1 (North Shore-LIJ Health System Laboratories)CDC rRT-PCR assayDetection of 2009 H1N1 influenza virus
Ginocchio et al. (2009); Retrospective analysis of clinical samples; Study Period: 2009 H1N1 outbreakPatients with suspected respiratory infection during 2009 H1N1 outbreak; Sample Size: 2,715 patient nasopharyngeal swab samples; Number of Sites: 1 (North Shore-LIJ Health System Laboratories)CDC rRT-PCR assayDetection of 2009 H1N1 influenza virus

Indications for Use

The xTAG™ Respiratory Viral Panel (RVP) is a qualitative nucleic acid multiplex test intended for the simultaneous detection and identification of multiple respiratory virus nucleic acids in nasopharyngeal swabs from individuals suspected of respiratory tract infections. The following virus types and subtypes are identified using RVP: Influenza A, Influenza A subtype H1, Influenza A subtype H3, Influenza B, Respiratory Syncytial Virus subtype A, Respiratory Syncytial Virus subtype B, Parainfluenza 1, Parainfluenza 2, and Parainfluenza 3 virus, Human Metapneumovirus, Rhinovirus, and Adenovirus. The detection and identification of specific viral nucleic acids from individuals exhibiting signs and symptoms of respiratory infection aids in the diagnosis of respiratory viral infection if used in conjunction with other clinical and laboratory findings. It is recommended that specimens found to be negative for Influenza B, Respiratory Syncytial Virus subtype A and B, Parainfluenza 1, Parainfluenza 2, Parainfluenza 3 and Adenovirus, after examination using RVP be confirmed by cell culture. Negative results do not preclude respiratory virus infection and should not be used as the sole basis for diagnosis, treatment or other management decisions. Positive results do not rule out bacterial infection, or co-infection with other viruses. The agent detected may not be the definite cause of disease. The use of additional laboratory testing (e.g. bacterial culture, immunofluorescence, radiography) and clinical presentation must be taken into consideration in order to obtain the final diagnosis of respiratory viral infection.

Device Story

xTAG RVP is a multiplex nucleic acid assay for simultaneous detection of respiratory viruses in nasopharyngeal swabs; identifies Influenza A (including H1/H3 subtypes), Influenza B, RSV A/B, Parainfluenza 1-3, Human Metapneumovirus, Rhinovirus, and Adenovirus. Device operates on Luminex 100 IS and 200 systems; utilizes nucleic acid amplification and multiplex detection. Intended for clinical laboratory use to aid diagnosis; results must be interpreted alongside clinical findings and other laboratory tests. Does not detect Adenovirus species C or serotypes 7a/41; Rhinovirus primers cross-react with Enterovirus. 2009 H1N1 influenza detection is limited to the matrix gene (unsubtypeable as H1 or H3 by RVP).

Clinical Evidence

Clinical performance evaluated via two studies (Ginocchio & George, 2009; Ginocchio et al., 2009) during the 2009 H1N1 outbreak. In one study (n=1,382), 141 samples identified as Influenza A positive but unsubtypeable by xTAG RVP were tested; 99/101 samples confirmed as 2009 H1N1 via CDC rRT-PCR. A second study (n=2,715) showed 1,108 samples identified as 'flu A unsubtypeable' by xTAG RVP were confirmed as 2009 H1N1 by CDC rRT-PCR.

Technological Characteristics

Multiplex nucleic acid detection assay; utilizes Luminex 100 IS and 200 instrument systems for signal detection. Qualitative test format.

Indications for Use

Indicated for qualitative detection/identification of respiratory viral nucleic acids in nasopharyngeal swabs from patients suspected of respiratory tract infections. Targets: Influenza A (H1, H3), Influenza B, RSV (A, B), Parainfluenza 1-3, Human Metapneumovirus, Rhinovirus, Adenovirus. Not for sole diagnostic use; results must be interpreted with clinical/lab findings.

Regulatory Classification

Identification

A respiratory viral panel multiplex nucleic acid assay is a qualitative in vitro diagnostic device intended to simultaneously detect and identify multiple viral nucleic acids extracted from human respiratory specimens or viral culture. The detection and identification of a specific viral nucleic acid from individuals exhibiting signs and symptoms of respiratory infection aids in the diagnosis of respiratory viral infection when used in conjunction with other clinical and laboratory findings. The device is intended for detection and identification of a combination of the following viruses:(1) Influenza A and Influenza B; (2) Influenza A subtype H1 and Influenza A subtype H3; (3) Respiratory Syncytial Virus subtype A and Respiratory Syncytial Virus subtype B; (4) Parainfluenza 1, Parainfluenza 2, and Parainfluenza 3 virus; (5) Human Metapneumovirus; (6) Rhinovirus; and (7) Adenovirus.

Special Controls

*Classification.* Class II (special controls). The special controls are:(1) FDA's guidance document entitled “Class II Special Controls Guidance Document: Respiratory Viral Panel Multiplex Nucleic Acid Assay;” (2) For a device that detects and identifies Human Metapneumovirus, FDA's guidance document entitled “Class II Special Controls Guidance Document: Testing for Human Metapneumovirus (hMPV) Using Nucleic Acid Assays;” and (3) For a device that detects and differentiates Influenza A subtype H1 and subtype H3, FDA's guidance document entitled “Class II Special Controls Guidance Document: Testing for Detection and Differentiation of Influenza A Virus Subtypes Using Multiplex Nucleic Acid Assays.” See § 866.1(e) for the availability of these guidance documents.

Submission Summary (Full Text)

{0} 1 # 510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY A. 510(k) Number: K091667 B. Purpose for Submission: Request to update the package insert on studies that have evaluated the xTAG RVP performance on specimens infected with 2009 H1N1 influenza. C. Measurand: See K063765 D. Type of Test: See K063765 E. Applicant: Luminex Molecular Diagnostics Inc. F. Proprietary and Established Names: xTAG™ Respiratory Viral Panel Common Name: Respiratory Viral Panel (RVP) Multiplex Nucleic Acid Detection Assay G. Regulatory Information: 1. Regulation section: 21 CFR 866.3980, Respiratory viral panel multiplex nucleic acid assay 2. Classification: Class II 3. Product code: OCC, OEM, OEP 4. Panel: Microbiology (83) H. Intended Use: 1. Intended use(s): The xTAG™ Respiratory Viral Panel (RVP) is a qualitative nucleic acid multiplex test intended for the simultaneous detection and identification of multiple respiratory virus nucleic acids in nasopharyngeal swabs from individuals suspected of respiratory tract infections. The following virus types and subtypes are identified using RVP: Influenza A, Influenza A subtype H1, Influenza A subtype H3, Influenza B, Respiratory Syncytial Virus subtype A, Respiratory Syncytial Virus subtype B, Parainfluenza 1, Parainfluenza 2, and Parainfluenza 3 virus, Human Metapneumovirus, Rhinovirus, and Adenovirus. The detection and identification of specific viral nucleic acids from individuals exhibiting signs and symptoms of respiratory infection aids in the diagnosis of respiratory viral infection if used in conjunction with other clinical and laboratory findings. It is recommended that specimens found to be negative for Influenza B, Respiratory Syncytial Virus subtype A and B, Parainfluenza 1, Parainfluenza 2, Parainfluenza 3 and Adenovirus, after examination using RVP be confirmed by cell culture. Negative results do not preclude respiratory virus infection and should not be used as the sole basis for diagnosis, treatment or other management decisions. Positive results do not rule out bacterial infection, or co-infection with other viruses. The agent detected may not be the definite cause of disease. The use of additional laboratory testing (e.g. bacterial culture, immunofluorescence, radiography) and clinical presentation must be taken into consideration in order to obtain the final diagnosis of respiratory viral infection. {1} Due to seasonal prevalence, performance characteristics for Influenza A/H1 were established primarily with retrospective specimens. The RVP assay cannot adequately detect Adenovirus species C, or serotypes 7a and 41. The RVP primers for detection of rhinovirus cross-react with enterovirus. A rhinovirus reactive result should be confirmed by an alternate method (e.g. cell culture). Performance characteristics for Influenza A Virus were established when Influenza A/H3 and A/H1 were the predominant Influenza A viruses in circulation. When other Influenza A viruses are emerging, performance characteristics may vary. If infections with a novel Influenza A virus is suspected based on current clinical and epidemiological screening criteria recommended by public health authorities, specimens should be collected with appropriate infection control precautions for novel virulent Influenza viruses and sent to a state or local health department for testing. Viral culture should not be attempted in these cases unless a BSL 3+ facility is available to receive and culture specimens. 2. Indication(s) for use: Same as Intended Use 3. Special conditions for use statement(s): For prescription use only 4. Special instrument requirements: Luminex® Instrument (100 IS and 200 systems) I. Device Description: See K063765 J. Substantial Equivalence Information: 1. Predicate device name(s): See K063765 2. Predicate 510(k) number(s): See K063765 3. Comparison with predicate: See K063765 K. Standard/Guidance Document Referenced (if applicable): See K063765 L. Test Principle: See K063765 M. Performance Characteristics (if/when applicable): 1. Analytical performance: See K063765 2. Comparison studies: See K063765 3. Clinical studies: See K063765 Additional clinical supportive data: {2} The xTAG RVP can detect the matrix gene of 2009 H1N1 influenza virus but can not identify the hemagglutinin gene of the 2009 H1N1 influenza virus in clinical specimens. The paragraphs below summarize two studies by Dr. Christine Ginocchio, Director of Microbiology, Virology and Molecular Diagnostics at North Shore-LIJ Health System Laboratories (Ginocchio & George, 2009; Ginocchio et al. 2009): In a study carried out during the 2009 H1N1 influenza outbreak in New York (Ginocchio & George, 2009), a total of 1,382 patient nasopharyngeal swab samples were initially tested with a variety of method including rapid antigen tests (n=1095), direct immunofluorescence (n=1164), and rapid virus culture (n=1140). Samples that tested positive for Influenza A with any of these methods, or derived from patients with a high potential to be infected with the 2009 H1N1 influenza strain, were further tested with xTAG RVP (n=375). A total of 201 of these samples were identified as Influenza A positive by the RVP assay, two samples contained Influenza B, and other respiratory viruses in 58 samples (adenovirus, metapneumovirus, Parainfluenza 1, 2, 3, RSV, and rhinovirus). Sixty of the 201 Influenza A positive samples were identified by xTAG RVP as seasonal strains (2 as H1 and 58 as H3). The remaining 141 Influenza A positive samples were negative for both H1 and H3 by xTAG RVP (unsubtypeable). Frozen residual portions of 101 of the 141 unsubtypeable samples were forwarded to the Laboratory of Viral Diseases (Albany, NY) for further testing with the CDC rRT-PCR assay for 2009 H1N1 influenza. A total of 99 of the 101 specimens tested with the CDC assay were identified as positive for the 2009 H1N1 influenza virus (CT<37). The two remaining specimens produced weak positive signals (CT>37) on one or more of the influenza targets and could not be classified as positive for the 2009 H1N1 influenza strain. These two samples also produced weak positive signals in the RVP assay. A study by Ginocchio et al. (2009) evaluated the performance of a variety of diagnostic assays, including the xTAG RVP, for the 2009 H1N1 influenza virus surveillance. In this study, a total of 2,715 patient nasopharyngeal swab samples were tested by xTAG RVP and 1265 of these were positive for influenza A. Of the 1265, 1108 were "flu A unsubtypeable", 151 were seasonal H3N2 and 6 were seasonal H1N1. Of the 1108 Influenza A unsubtypeable with the xTAG RVP, all were confirmed to be 2009 H1N1 influenza with the CDC rRT-PCR assay. 4. Clinical cut-off: See K063765 5. Expected values/Reference range: See K063765 N. Proposed Labeling: The labeling is sufficient and it satisfies the requirements of 21 CFR Part 809.10. O. Conclusion: The submitted information in this premarket notification is complete and supports a substantial equivalence decision.
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...