SKELTEX ISV

K091234 · Skeltex Technologies, Inc. · NDN · Feb 16, 2010 · Orthopedic

Device Facts

Record IDK091234
Device NameSKELTEX ISV
ApplicantSkeltex Technologies, Inc.
Product CodeNDN · Orthopedic
Decision DateFeb 16, 2010
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 888.3027
Device ClassClass 2
AttributesTherapeutic

Intended Use

The Skeltex ISV is intended for percutaneous delivery of PMMA bone cement in vertebroplasty or kyphoplasty procedures in the treatment of pathological fractures of the vertebrae. Painful vertebral compression fractures may result from osteoporosis, benign lesions (hemangioma), and malignant lesions (metastatic cancers, myeloma).

Device Story

Skeltex ISV is a delivery system for PMMA bone cement; used in percutaneous vertebroplasty or kyphoplasty procedures. Device facilitates controlled injection of bone cement into vertebral bodies to treat pathological fractures. Operated by physicians in clinical/surgical settings. Benefits include stabilization of fractured vertebrae and pain relief for patients suffering from osteoporosis or vertebral lesions.

Clinical Evidence

No clinical data provided; substantial equivalence determination based on device description and intended use.

Technological Characteristics

Device is a delivery system for PMMA bone cement (21 CFR 888.3027). Mechanical delivery mechanism for viscous bone cement. No electronic, software, or algorithmic components described.

Indications for Use

Indicated for percutaneous delivery of PMMA bone cement in vertebroplasty or kyphoplasty for patients with painful vertebral compression fractures caused by osteoporosis, benign lesions (hemangioma), or malignant lesions (metastatic cancers, myeloma).

Regulatory Classification

Identification

Polymethylmethacrylate (PMMA) bone cement is a device intended to be implanted that is made from methylmethacrylate, polymethylmethacrylate, esters of methacrylic acid, or copolymers containing polymethylmethacrylate and polystyrene. The device is intended for use in arthroplastic procedures of the hip, knee, and other joints for the fixation of polymer or metallic prosthetic implants to living bone.

Special Controls

*Classification.* Class II (special controls). The special control for this device is the FDA guidance document entitled “Class II Special Controls Guidance Document: Polymethylmethacrylate (PMMA) Bone Cement.”

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ Image /page/0/Picture/0 description: The image shows a black and white logo. The logo consists of a circle with text around the top half, and a stylized bird-like figure inside the circle. Below the circle, there is a dark, irregular shape that appears to be a shadow or part of the design. The text around the circle is not clearly legible due to the image quality. DEPARTMENT OF HEALTH & HUMAN SERVICES Public Health Service Food and Drug Administration 10903 New Hampshire Avenue Document Control Room W-O66-0609 Silver Spring, MD 20993-0002 Skeltex Technologies, Inc. % Mr. George Papagiannis 72 De Mortagne Boulevard Boucherville, Quebec Canada J4B 6Y4 Re: K091234 FEB 1 6 2010 Trade/Device Name: Skeltex ISV Regulation Number: 21 CFR 888.3027 Regulation Name: Polymethylmethacrylate (PMMA) bone cement Regulatory Class: II Product Code: NDN, KIH Dated: February 8, 2010 Received: February 12, 2010 Dear Mr. Papagiannis: We have reviewed your Section 310(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. {1}------------------------------------------------ Page 2 – Mr. George Papagiannis If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please go to http://www.fda.gov/AboutFDA/CentersOffices/CDRH/CDRHOffices/ucm115809.htm for the Center for Devices and Radiological Health's (CDRH's) Office of Compliance. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/Reportal":chtml for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance. You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fdagov/MedicalDevices/ResourcesforYou/Industry/default.htm. Sincerely yours, Varian H. Fry ACT. ACTING DIRECTOR Mark N. Melkerson Director Division of Surgical, Orthopedic, and Restorative Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {2}------------------------------------------------ Skeltex Technologies Inc. ## Indications for Use Statement 510(k) Number: K091234 Device Name: Skeltex ISV Indications for Use: The Skeltex ISV is intended for percutaneous delivery of PMMA bone cement in vertebroplasty or kyphoplasty procedures in the treatment of pathological fractures of the vertebrae. Painful vertebral compression fractures may result from osteoporosis, benign lesions (hemangioma), and malignant lesions (metastatic cancers, myeloma). Prescription Use (Per 21 CFR 801 Subpart D) ・・ OR Over-The-Counter Use (Per 21 CFR 801 Subpart C) PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED Concurrence of CDRH, Office of Device Evaluation (ODE) Vaughn V. Oliphant FOR M.MELKERSON Division of Surgical, Orthopedic, and Restorative Devices 510(k) Number K091234
Innolitics
510(k) Summary
Decision Summary
Classification Order
Enter a record ID and click Load to view the document.
100%