1.5MM SMALL LOCKING PLATE, 1.5MM NON-LOCKING AND LOCKING SCREWS
K090492 · DePuy Orthopaedics, Inc. · HRS · Mar 31, 2009 · Orthopedic
Device Facts
| Record ID | K090492 |
| Device Name | 1.5MM SMALL LOCKING PLATE, 1.5MM NON-LOCKING AND LOCKING SCREWS |
| Applicant | DePuy Orthopaedics, Inc. |
| Product Code | HRS · Orthopedic |
| Decision Date | Mar 31, 2009 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 888.3030 |
| Device Class | Class 2 |
| Attributes | Therapeutic |
Intended Use
The DePuy Small Locking Plate System is intended for stabilization and fixation of small bone fragments in fresh fractures, revision procedures, joint fusion and reconstructions of small bones of the hand, foot, wrist, ankle, humerus, scapula, finger, toe, pelvis and craniomaxillofacial skeleton, particularly in osteopenic bone.
Device Story
Small Locking Plate System consists of metallic bone fixation plates and accessories. Used by orthopedic surgeons for stabilization and fixation of small bone fragments in fractures, revisions, joint fusions, and reconstructions. Designed for use in small bones including hand, foot, wrist, ankle, humerus, scapula, finger, toe, pelvis, and craniomaxillofacial skeleton. Particularly indicated for osteopenic bone. Device provides mechanical support to bone fragments to facilitate healing.
Clinical Evidence
Bench testing only.
Technological Characteristics
Metallic bone fixation plates and accessories. Design and materials are identical to currently marketed predicate devices.
Indications for Use
Indicated for stabilization and fixation of small bone fragments in fresh fractures, revision procedures, joint fusion, and reconstructions of small bones (hand, foot, wrist, ankle, humerus, scapula, finger, toe, pelvis, craniomaxillofacial skeleton), particularly in patients with osteopenic bone.
Regulatory Classification
Identification
Single/multiple component metallic bone fixation appliances and accessories are devices intended to be implanted consisting of one or more metallic components and their metallic fasteners. The devices contain a plate, a nail/plate combination, or a blade/plate combination that are made of alloys, such as cobalt-chromium-molybdenum, stainless steel, and titanium, that are intended to be held in position with fasteners, such as screws and nails, or bolts, nuts, and washers. These devices are used for fixation of fractures of the proximal or distal end of long bones, such as intracapsular, intertrochanteric, intercervical, supracondylar, or condylar fractures of the femur; for fusion of a joint; or for surgical procedures that involve cutting a bone. The devices may be implanted or attached through the skin so that a pulling force (traction) may be applied to the skeletal system.
Related Devices
- K081546 — SMALL BONE LOCKING PLATING SYSTEM · DePuy Orthopaedics, Inc. · Aug 26, 2008
- K072083 — SMALL FRAGMENT LOCKING PLATING SYSTEM · DePuy Orthopaedics, Inc. · Oct 25, 2007
- K092247 — SYNTHES LOCKING HAND PLATES · Synthes (Usa) · Sep 25, 2009
- K022325 — NORMED TITANIUM OSTEOTOMY PLATING SYSTEM · Osteomedics, Inc. · Sep 9, 2002
- K222194 — Baby Gorilla®/Gorilla® Plating System · Paragon 28, Inc. · Aug 19, 2022
Submission Summary (Full Text)
{0}------------------------------------------------
# SECTION 5 - 510(K) SUMMARY
Submitted by:
DePuy Orthopaedics, Inc. 700 Orthopaedic Drive Warsaw, IN 46581 Phone: (305) 269-6386 Fax: (305) 269-6441
Suzana Otaño, Project Manager, Regulatory Affairs Contact Person:
Date Prepared: February 23, 2009
Proprietary Name: Small Locking Plate System
Common Name: Plate, Fixation, Bone
Classification Single/multiple component metallic bone fixation appliances and accessories (21 CFR § 888.3030) Name:
Predicate Devices:
The Small Locking Plate System is substantially equivalent to currently marketed devices.
Intended Use: The DePuy Small Locking Plate System is intended for stabilization and fixation of small bone fragments in fresh fractures, revision procedures, joint fusion and reconstructions of small bones of the hand, foot, wrist, ankle, humerus, scapula, finger, toe, pelvis and craniomaxillofacial skeleton. particularly in osteopenic bone.
Technoloqical The technological characteristics of the Small Locking Plate Characteristics: System are the same as the predicate devices including design and material.
Summarv of Substantial Equivalence: The Small Locking Plate System is substantially equivalent to currently marketed devices as demonstrated with pre-clinical data. No new issues of safety or efficacy have been raised.
MAR 3 1 2009
{1}------------------------------------------------
DEPARTMENT OF HEALTH & HUMAN SERVICES
Image /page/1/Picture/13 description: The image shows the seal of the Department of Health & Human Services, USA. The seal features a stylized eagle with outstretched wings, symbolizing protection and care. The words "DEPARTMENT OF HEALTH & HUMAN SERVICES. USA" are arranged in a circular pattern around the eagle.
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
Depuy Orthopedics, Inc. % Ms. Suzana Otano Project Manager, Regulatory Affairs 700 Orthopaedic Drive Warsaw, Indiana 46581
Re: K090492
Trade/Device Name: Small Locking Plate System Regulation Number: 21 CFR 888.3030 Regulation Name: Single/multiple component metallic bone fixation appliances and accessories
MAR 3 1 2009
II
Regulatory Class: II Product Code: HRS Dated: February 23, 2009 Received: February 25, 2009
Dear Ms. Otano:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
{2}------------------------------------------------
#### Page 2 - Ms. Suzana Otano
This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Center for Devices and Radiological Health's (CDRH's) Office of Compliance at (240) 276-0120. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding postmarket surveillance, please contact CDRH's Office of Surveillance and Biometric's (OSB's) Division of Postmarket Surveillance at (240) 276-3474. For questions regarding the reporting of device adverse events (Medical Device Reporting (MDR)), please contact the Division of Surveillance Systems at (240) 276-3464. You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at toll-free number (800) 638-2041 or (240) 276-3150 or the Internet address http://www.fda.gov/cdrh/industry/support/index.html.
Sincerely yours
for
Mark N. Mcllierson
Mark N. Melk Director Division of General, Restorative and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{3}------------------------------------------------
K090492
## SECTION 4 - INDICATIONS FOR USE STATEMENT
510(k) Number:
#### Small Locking Plate System Device Name:
### Indications For Use:
The DePuy Small Locking Plate System is intended for stabilization and fixation of small bone fragments in fresh fractures, revision procedures, joint fusion and reconstructions of small bones of the hand, foot, wrist, ankle, humerus, scapula, finger, toe, pelvis and craniomaxillofacial skeleton, particularly in osteopenic bone.
X Prescription Use (Per 21 CFR 801 Subpart D)
AND/OR
Over-the-Counter (21 CFR 801 Subpart C)
(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
(Division Sign-Off) for MXAT
Division of General, Restorative,
and Neurological Devices
Page 1 of 1
510(k) Number_ 1090497
Small Locking Plate System Traditional 510(k) DePuy Orthopaedics, Inc.
Page 19 of 87