← Product Code [EZL](/productcode/EZL) · K090262

# PERCUCATH URINARY CATHETER (K090262)

_Percuvision, LLC · EZL · May 28, 2009 · Gastroenterology, Urology · SESE_

**Canonical URL:** https://fda.innolitics.com/device/K090262

## Device Facts

- **Applicant:** Percuvision, LLC
- **Product Code:** [EZL](/productcode/EZL.md)
- **Decision Date:** May 28, 2009
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 876.5130
- **Device Class:** Class 2
- **Review Panel:** Gastroenterology, Urology
- **Attributes:** Therapeutic, 3rd-Party Reviewed

## Indications for Use

The PercuCath™ Catheter is indicated for use in the drainage and/or collection and/or measurement of urine. It is intended to be used as a urological catheter inserted through the urethra for the purpose of draining urine and other fluids from the urinary tract. However, drainage is sometimes accomplished by suprapubic or other placement of the catheter, such as the nephrostomy tract.

## Device Story

PercuCath™ Urinary Catheter is a flexible, 100% silicone, latex-free, triple-lumen (3-way) Foley catheter. Features include a lubricious hydrophilic coating, a straight or angled council tip with an eyelet for guidewire insertion, a silicone balloon, and a two-way valve for balloon inflation/deflation. The three lumens facilitate urinary drainage, balloon control, and bladder irrigation. Available in 14-24 Fr sizes with 10 cc or 30 cc balloons. Used by clinicians to manage urinary drainage and fluid collection. The device is inserted into the urinary tract; the council tip allows for guidewire-assisted placement. Output is the passive drainage of urine into a collection container. Benefits include effective fluid management and facilitated catheterization via the council tip design.

## Clinical Evidence

Bench testing only. No clinical data provided.

## Technological Characteristics

100% silicone construction; latex-free; triple-lumen (3-way) design; lubricious hydrophilic coating; straight or angled council tip with eyelet; 14-24 Fr shaft sizes; 10 cc or 30 cc balloon; two-way valve for balloon inflation/deflation.

## Regulatory Identification

A urological catheter and accessories is a flexible tubular device that is inserted through the urethra and used to pass fluids to or from the urinary tract. This generic type of device includes radiopaque urological catheters, ureteral catheters, urethral catheters, coudé catheters, balloon retention type catheters, straight catheters, upper urinary tract catheters, double lumen female urethrographic catheters, disposable ureteral catheters, male urethrographic catheters, and urological catheter accessories including ureteral catheter stylets, ureteral catheter adapters, ureteral catheter holders, ureteral catheter stylets, ureteral catheterization trays, and the gastro-urological irrigation tray (for urological use).

## Predicate Devices

- Bardex® Lubri-Sil® 3-Way Foley Catheter ([K002868](/device/K002868.md))
- Dover® 100% Silicone Foley Council Tip Catheter ([K860484](/device/K860484.md))

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

510(k), [Percuvision]

Page 18 of 50

K090262

MAY 28 2009

# 5. 510(k) Summary as required by 21 CFR 807.92(c) -

510(k) Owner: Percuvision LLC 765 North Hamilton Road. Suite 260A Gahanna, Ohio 43230 (614) 337-8700 Telephone: Facsimile: (614) 337-2274

Barbara S. Fant, Pharm.D. Contact person: Clinical Research Consultants, Inc. 310 Terrace Avenue Suite 201 Cincinnati, OH 45220 (513) 961-8200 Phone: Facsimile: (513) 961-2858

November 04, 2008 Date:

Trade Name: PercuCath™ Urinary Catheter

Urological Foley catheter Common name:

Classification Name: Class II; 21 CFR 876.5130, Urological Catheter and Accessories

EZL: Catheter, Retention Type, Balloon Product Code:

#### Identification of a Legally Marketed Predicate Device

The PercuCath™ Urinary Catheter is substantially equivalent to the Bardex® Lubri-Sil® 3-Way Folev Catheter marketed by C.R. Bard. Inc., 510(k) Premarket Notification Number: K002868 FDA Product Code EZL. Secondly, it is substantially equivalent to the Dover® 100% Silicone Foley Council Tip Catheter with manufactured by Tyco Healthcare, 510(k) Premarket Notification Number: K860484, FDA Product Code KOD.

#### General Description

The PercuCath™ Urinary Catheter is a flexible tubular device that is inserted through the urethra and used to pass fluids to and from the urinary tract. The PercuCath™ Urinary Catheter is a 100% silicone, latex-free, triple lumen (3-Way) Foley catheter with a lubricious hydrophilic coating and a straight or angled council tip to facilitate insertion. It is composed of a silicone tube that trifurcates into three lumens, a silicone balloon, and a two-way valve. When activated, the valve permits flow in either of two directions, i.e., for inflation or deflation of the balloon. Of the three lumens, one lumen is used for urinary drainage and can

#### Percuvision LLC

Proprietary and Confidential Information

11/04/2008

{1}------------------------------------------------

510(k), [Percuvision]

Page 19 of 50

be connected to a urine collection container (drainage bag or urine meter); one lumen has a two-way valve for inflation/deflation of the Foley balloon; and, the third lumen can be used for irrigation of the bladder. The council tip has an opening (eyelet) in the tip that can be used to pass a guidewire or similar device to facilitate catheter insertion. The PercuCath™ Urinary Catheter will be available with a single eyelet or double eyelet, 14 through 24 Fr. Shafts (i.e.,14, 16, 18, 20, 22, and 24), and either a 10 cc or 30 cc balloon.

#### Indications for Use and Intended Use

The PercuCath™ Catheter is indicated for use in the drainage and/or collection and/or measurement of urine. It is intended to be used as a urological catheter inserted through the urethra for the purpose of draining urine and other fluids from the urinary tract. However, drainage is sometimes accomplished by suprapubic or other placement of the catheter, such as the nephrostomy tract.

#### Performance Data

Mechanical testing was performed on the PercuCath™ Urinary Catheter and the results demonstrate that the PercuCath™ Urinary Catheter met the design specifications for the device and were substantially equivalent to the predicate devices.

#### Basis of Substantial Equivalence

The PercuCath™ Urinary Catheter is substantially equivalent to the Bardex® Lubri-Sil® 3-Way Foley Catheter manufactured by C.R. Bard, Inc. in material, intended use, basic design concept, and biomechanical properties. Secondly, it is substantially equivalent to the Dover® 100% Silicone Foley Council Tip Catheter in its intended use and its council tip with an eyelet.

{2}------------------------------------------------

### DEPARTMENT OF HEALTH & HUMAN SERVICES

Image /page/2/Picture/1 description: The image shows the seal of the Department of Health & Human Services (HHS). The seal features the department's name arranged in a circular pattern around a stylized emblem. The emblem consists of a stylized eagle with three lines representing its wings.

#### Public Health Service

MAY 28 2009

Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850

Percuvision LLC % Mr. Jeff D. Rongero Senior Project Engineer UL Health Sciences -Underwriters Laboratories, Inc. 12 Laboratory Drive RESEARCH TRIANGLE PARK NC 27709-3995

Re: K090262

Trade/Device Name: PercuCath Urinary Catheter Regulation Number: 21 CFR 876.5130 Regulation Name: Urological catheter and accessories Regulatory Class: II Product Code: EZL Dated: May 12, 2009 Received: May 13, 2009

Dear Mr. Rongero: .

We have reviewed your Section 510(k) premarket notification of intent to market the device w o have and have and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.

{3}------------------------------------------------

Page 2

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Center for Devices and Radiological Health's (CDRH's) Office of Compliance at one of the following numbers, based on the regulation number at the top of this letter.

(Gastroenterology/Renal/Urology) (240) 276-0115 21 CFR 876.xxx (240) 276-0115 (Obstetrics/Gynecology) 21 CFR 884.xxx (240) 276-0120 21 CFR 892.xxx (Radiology) Other (240) 276-0100

Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please contact the CDRH/Office of Surveillance and Biometrics/Division of Postmarket Surveillance at 240-276-3464. For more information regarding the reporting of adverse events, please go to http://www.fda.gov/cdrh/mdr/.

You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (240) 276-3150 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html.

Sincerely yours,

Janine M. Morris Acting Director, Division of Reproductive, Abdominal, and Radiological Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{4}------------------------------------------------

## 4. Indications for Use Statement

KO90262 510(k) Number (if known):

Device Name: PercuCath™ Urinary Catheter

#### Indications for Use:

The PercuCath™ Catheter is indicated for use in the drainage and/or collection and/or measurement of urine. It is intended to be used as a urological catheter inserted through the urethra for the purpose of draining urine and other fluids from the urinary tract. However, drainage is sometimes accomplished by suprapubic or other placement of the catheter, such as the nephrostomy tract.

Prescription Use X

OR

Over-The-Counter Use

### PLEASE DO NOT WRITE BELOW THIS LINE – CONTINUE ON ANOTHER PAGE IF NEEDED

Concurrence of CDRH, Office of Device Evaluation (ODE)

Huld Reuner

(Division Sign Off) Division of Reproductive, Abdominal, and Radiological Devices K090262

510(k) Number_

Percuvision LLC Proprietary and Confidential Information

11/04/2008

---

**Source:** [https://fda.innolitics.com/device/K090262](https://fda.innolitics.com/device/K090262)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
