← Product Code [NJM](/productcode/NJM) · K082974

# MYSTIQUE MB CERAMIC BRACKETS (K082974)

_Dentsply Interntional · NJM · Nov 7, 2008 · Dental · SESE_

**Canonical URL:** https://fda.innolitics.com/device/K082974

## Device Facts

- **Applicant:** Dentsply Interntional
- **Product Code:** [NJM](/productcode/NJM.md)
- **Decision Date:** Nov 7, 2008
- **Decision:** SESE
- **Submission Type:** Special
- **Regulation:** 21 CFR 872.5470
- **Device Class:** Class 2
- **Review Panel:** Dental
- **Attributes:** Therapeutic

## Indications for Use

Indicated for orthodontic movement of natural teeth, excluding mandibular bicuspid teeth.

## Device Story

Mystique MB Ceramic Brackets are orthodontic appliances bonded to teeth to facilitate tooth movement. The device consists of a transparent ceramic bracket featuring a mechanical lock base with rhomboid and 'torque-in-the-base' design features; optional glass coating is available in the wire slot. The bracket is used by orthodontists in a clinical setting; it receives mechanical force transmitted through a flexible orthodontic wire to alter tooth position. The device is a modification of a previously cleared ceramic bracket, maintaining the same fundamental scientific technology and composition. It benefits patients by providing a transparent aesthetic option for orthodontic treatment.

## Clinical Evidence

No clinical data. Bench testing only.

## Technological Characteristics

Ceramic orthodontic brackets with mechanical lock base. Features include rhomboid shape, 'torque-in-the-base' design, and optional glass coating in the wire slot. Transparent material. Same composition as predicate device.

## Regulatory Identification

An orthodontic plastic bracket is a plastic device intended to be bonded to a tooth to apply pressure to a tooth from a flexible orthodontic wire to alter its position.

## Predicate Devices

- Orthodontic Ceramic Brackets ([K042178](/device/K042178.md))

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

K082974

# NOV - 7 2008

DENTSPLY Internat World Headquarters Susquehanna Commer 221 West Philadelphic ork, PA 17405-087 800) 877-0020 Fax 17171 849-4343 ww.dentsply.com

## 510(k) SUMMARY

CONTACT: Helen Lewis DATE PREPARED: October 2, 2008 TRADE OR PROPRIETARY NAME: Mystique MB Ceramic Brackets CLASSIFICATION NAME: Orthodontic Ceramic Brackets 872.5470 PREDICATE DEVICES: Orthodontic Ceramic Brackets K042178

DEVICE DESCRIPTION: The Orthodontic Ceramic Bracket is in commercial distribution and consists of a chemically treated base. The modification to the Orthodontic Ceramic Bracket consists of a mechanical lock base and the brackets: are referred to as the Mystique MB Ceramic Brackets. Mystique MB Ceramic Brackets are bonded to teeth to apply pressure to the tooth, transmitted through a flexible orthodontic wire, to alter the tooth position. The mechanical lock base includes rhomboid and "torque-in-the-base" features. The bracket is transparent and has indented walls and is available with or without glass coating in the wire slot.

INTENDED USE: Indicated for orthodontic movement of natural teeth, excluding mandibular bicuspid teeth.

(ECHNOLOGICAL CHARACTERISTICS: The Mystique MB Ceramic Brackets represent a minor design modification to K042178. There are no changes in intended use or fundamental scientific technology.

All of the components found in Mystique MB Ceramic Brackets have been used in legally marketed devices and/or were found safe for dental use. Mystique MB Ceramic Brackets are the same composition as the predicate device. Therefore, further biocompatibility testing is not necessary.

We believe that the prior use of the components of Mystique MB Ceramic Brackets in the legally marketed devices, the performance data provided, and previously submitted biocompatibility data support the safety and effectiveness of Mystique MB Ceramic Brackets for the indicated uses.

{1}------------------------------------------------

Image /page/1/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo is a circular seal with the words "DEPARTMENT OF HEALTH & HUMAN SERVICES USA" around the perimeter. Inside the circle is a stylized image of an eagle.

Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850

Ms. Helen Lewis Director of Corporate Compliance and Regulatory Affairs DENTSPLY International, Incorporated Susquehanna Commerce Center 221 West Philadelphia Street, Suite 60 York, Pennsylvania 17405-0872

NOV - 7 2008

Re: K082974

Trade/Device Name: Mystique MB Ceramic Brackets Regulation Number: 21 CFR 872.5470 Regulation Name: Orthodontic Plastic Bracket Regulatory Class: II Product Code: NJM Dated: October 2, 2008 Received: October 9, 2008

Dear Ms. Lewis:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

{2}------------------------------------------------

### Page 2 - Ms. Lewis

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.

This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Center for Devices and Radiological Health's (CDRH's) Office of Compliance at (240) 276-0115. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding postmarket surveillance, please contact CDRH's Office of Surveillance and Biometric's (OSB's) Division of Postmarket Surveillance at 240-276-3474. For questions regarding the reporting of device adverse events (Medical Device Reporting (MDR)), please contact the Division of Surveillance Systems at 240-276-3464. You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (240) 276-3150 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html.

Sincerely yours.

Sutte Y. Mchail Ows..

DR. CHIL LIN Chiu S. Lin, Ph. D FOR Division Director Division of Anesthesiology, General Hospital. Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{3}------------------------------------------------

# INDICATIONS FOR USE STATEMENT

510(k) Number (if known):

K082974

Device Name: Mystique MB Ceramic Brackets

Indications for Use:

Indicated for orthodontic movement of natural teeth, excluding mandibular bicuspid teeth.

These are the same indications for use previously cleared for K042178.

Prescription Use __ X (Part 21 CFR 801 Subpart D) AND/OR

Over-The-Counter Use (21 CFR 801 Subpart C)

(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)

Concurrence of CDRH Office of Device Evaluation (ODE)

MGR

(Division Sign-Off) Division of Anesthesiology, General Hospital Infection Control, Dental Device

510(k) Number: K082974

Premarket Notification

Mystique MB Ceramic Brackets

DENTSPLY International

000017

---

**Source:** [https://fda.innolitics.com/device/K082974](https://fda.innolitics.com/device/K082974)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
