← Product Code [GAM](/productcode/GAM) · K082662

# V-LOC 180 ABSORBABLE WOUND CLOSURE DEVICE (K082662)

_Surgical Devices, Tyco Healthcare Group LP · GAM · Mar 26, 2009 · General, Plastic Surgery · SESE_

**Canonical URL:** https://fda.innolitics.com/device/K082662

## Device Facts

- **Applicant:** Surgical Devices, Tyco Healthcare Group LP
- **Product Code:** [GAM](/productcode/GAM.md)
- **Decision Date:** Mar 26, 2009
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 878.4493
- **Device Class:** Class 2
- **Review Panel:** General, Plastic Surgery
- **Attributes:** Therapeutic

## Indications for Use

V-Loc™ 180 Absorbable Wound Closure Device is indicated for soft tissue approximation in where use of an absorbable suture is appropriate.

## Device Story

V-Loc 180 is a synthetic absorbable wound closure device; monofilament suture composed of copolymer of glycolic acid and trimethylene carbonate. Features unidirectional barbs along axis to facilitate tissue approximation without knots. Supplied in pre-cut lengths with attached needles; available dyed (D&C Green No. 6) or clear. Used by surgeons for soft tissue approximation. Device functions by anchoring tissue via barbs; eliminates need for traditional knot tying. Benefits include simplified closure procedure and secure tissue approximation.

## Clinical Evidence

Bench testing only. Performance testing conducted to verify safety and effectiveness for intended use.

## Technological Characteristics

Monofilament suture; copolymer of glycolic acid and trimethylene carbonate. Unidirectional barbs. Sizes USP 2-0, 0, 1. Materials compliant with ISO 10993-1. Sterilized device.

## Regulatory Identification

An absorbable poly(glycolide/l-lactide) surgical suture (PGL suture) is an absorbable sterile, flexible strand as prepared and synthesized from homopolymers of glycolide and copolymers made from 90 percent glycolide and 10 percent l-lactide, and is indicated for use in soft tissue approximation. A PGL suture meets United States Pharmacopeia (U.S.P.) requirements as described in the U.S.P. “Monograph for Absorbable Surgical Sutures;” it may be monofilament or multifilament (braided) in form; it may be uncoated or coated; and it may be undyed or dyed with an FDA-approved color additive. Also, the suture may be provided with or without a standard needle attached.

## Special Controls

*Classification.* Class II (special controls). The special control for this device is FDA's “Class II Special Controls Guidance Document: Surgical Sutures; Guidance for Industry and FDA.” See § 878.1(e) for the availability of this guidance document.

## Predicate Devices

- Syneture™ Maxon™ Synthetic Absorbable Suture ([K990951](/device/K990951.md))
- Quill™ Synthetic Absorbable Barbed Suture ([K042075](/device/K042075.md))

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

K062662 Page 1 of 1

## 510(k) Summary of Safety and Effectiveness

| SUBMITTER:                        | Surgical Devices, a global business unit<br>of Tyco Healthcare Group LP (d/b/a Covidien)<br>60 Middletown Avenue<br>North Haven, CT 06473                                                                                                                                                      |
|-----------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| CONTACT PERSON:                   | Renee Borgesano<br>Manager, Regulatory Affairs<br>Tel. No.: (203) 492-6060                                                                                                                                                                                                                     |
| DATE PREPARED:                    | September 11, 2008                                                                                                                                                                                                                                                                             |
| TRADE/PROPRIETARY NAME:           | V-Loc <sup>TM</sup> 180 Absorbable Wound Closure Device                                                                                                                                                                                                                                        |
| COMMON/USUAL NAME:                | Synthetic Absorbable Suture                                                                                                                                                                                                                                                                    |
| CLASSIFICATION NAME:              | Polyglycolic Acid Absorbable Surgical Suture                                                                                                                                                                                                                                                   |
| PREDICATE DEVICE(S):              | Syneture <sup>TM</sup> Maxon <sup>TM</sup> Synthetic Absorbable Suture (K990951)                                                                                                                                                                                                               |
|                                   | Quill TM Synthetic Absorbable Barbed Suture (K042075)                                                                                                                                                                                                                                          |
| DEVICE DESCRIPTION:               | The V-Loc <sup>TM</sup> 180 Absorbable Wound Closure Device is a suture<br>prepared from a copolymer of glycolic acid and trimethylene carbonate.<br>Each device has unidirectional barbs along the axis of the monofilament.                                                                  |
|                                   | The V-Loc <sup>TM</sup> 180 Absorbable Wound Closure Device will be offered dyed<br>with D&C Green No. 6 (21 CFR 74.3206) or clear (undyed) in sizes USP<br>(EP) 2-0 (Metric 3), 0 (Metric 3.5) and 1 (Metric 4). They will be supplied<br>in pre-cut lengths affixed to various needle types. |
| INDICATIONS:                      | V-Loc <sup>TM</sup> 180 Absorbable Wound Closure Device is indicated for soft<br>tissue approximation where use of an absorbable suture is appropriate.                                                                                                                                        |
| TECHNOLOGICAL<br>CHARACTERISTICS: | V-Loc <sup>TM</sup> 180 Absorbable Wound Closure Device is substantially<br>equivalent to the predicate devices with regards to use in soft tissue<br>approximation.                                                                                                                           |
| MATERIALS:                        | All components of the V-Loc <sup>TM</sup> 180 Absorbable Wound Closure Device<br>are comprised of materials that are in compliance with ISO standard<br>10993-1.                                                                                                                               |
| PERFORMANCE DATA:                 | Performance testing was conducted to verify that the V-Loc <sup>TM</sup> 180<br>Absorbable Wound Closure Device is safe and effective and performs as<br>intended.                                                                                                                             |

.

{1}------------------------------------------------

## DEPARTMENT OF HEALTH & HUMAN SERVICES

Image /page/1/Picture/1 description: The image shows the logo for the U.S. Department of Health and Human Services. The logo features a stylized eagle with its wings spread, and the text "DEPARTMENT OF HEALTH & HUMAN SERVICES. USA" is arranged in a circular pattern around the eagle. The eagle is black, and the text is also black. The logo is simple and recognizable.

Public Health Service

MAR 2 6 2009

Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850

Covidien % Ms. Renee Borgesano Manager, Regulatory Affairs 60 Middletown Avenue North Haven, Connecticut 06473

Re: K082662

Trade/Device Name: V-Loc™ 180 Absorbable Wound Closure Device Regulation Number: 21 CFR 878.4493 Regulation Name: Absorbable poly(glycolide/L-lactide) surgical suture Regulatory Class: II Product Code: GAM Dated: February 26, 2009 Received: March 4, 2009

Dear Ms. Borgesano:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Fed-ral Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration,

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set

{2}------------------------------------------------

Page 2 -- Ms. Renee Borgesano

forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.

This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Center for Devices and Radiological Health's (CDRH's) Office of Compliance at (240) 276-0115. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding postmarket surveillance, please contact CDRH's Office of Surveillance and Biometric's (OSB's) Division of Protmarket, Surveillance at (240) 276-3474. For questions regarding the reporting of device adverse events (Medical Device Reporting (MDR)), please contact the Division of Surveillance Systems at (240) 276-3464. You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (240) 276-3150 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html.

Sincerely yours.

L.A., m. D.A.

Mark N. Melkerson Director Division of General, Restorative and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{3}------------------------------------------------

## Indications For Use

510(k) Number (if known): ____________________________________________________________________________________________________________________________________________________

Device Name: V-Loc™ 180 Absorbable Wound Closure Device

Indications For Use:

V-Loc™ 180 Absorbable Wound Closure Device is indicated for soft tissue approximation in where use of an absorbable suture is appropriate.

Prescription Use × (Part 21 CFR 801 Subpart D) AND/OR

Over-The-Counter Use (21 CFR 801 Subpart C)

(Please DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)

Concurrence of CDRH, Office of Device Evaluation (ODE)

Daniel Krone for MXM 3/26/2009

(Division Sign-Off) Division of General, Restorative, and Neurological Devices

510(k) Number K082662

---

**Source:** [https://fda.innolitics.com/device/K082662](https://fda.innolitics.com/device/K082662)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
