K082336 · New Mexico Software, Inc. · LLZ · Oct 15, 2008 · Radiology
Device Facts
Record ID
K082336
Device Name
XR-EXPRESS
Applicant
New Mexico Software, Inc.
Product Code
LLZ · Radiology
Decision Date
Oct 15, 2008
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 892.2050
Device Class
Class 2
Attributes
Software as a Medical Device
Indications for Use
XR-EXpress is a PACS and teleradiology system used to receive DICOM images, scheduling information and textual reports, organize and store them in an internal format, and to make that information available across a network via web and customized user interfaces. XR-EXpress is for hospitals, imaging centers, nursing homes, radiologist reading practices, and any user who requires and is granted access to patient image, demographic, and report information. Lossy compressed mammographic images and digitized film screen images must not be reviewed for primary image interpretations. Mammographic images may only be interpreted using an FDA approved monitor that offers at least 5 Mpixel resolution and meets other technical specifications reviewed and accepted by FDA. Moreover, it is the user's responsibility to ensure monitor quality, ambient light conditions, and image compression ratios are consistent with the clinical application.
Device Story
XR-EXpress is a PACS/teleradiology system for image management and distribution. Inputs include DICOM images, scheduling info, and textual reports received via network or direct DICOM connection. System components include Capture (data ingestion), Server (registration, archiving, association with prior cases), and Viewer (web-based or dedicated workstation for diagnosis). Users include radiologists, hospital staff, and authorized clinicians. System organizes data into worklists; supports dictation and transcription of reports. Output is electronic or faxed reports and rendered images for clinical review. Physician intervention is required for all interpretations. Benefits include centralized access to patient imaging and reports across clinical settings, facilitating remote reading and efficient workflow.
Clinical Evidence
No clinical data. Validation testing consisted of bench-level stress testing of system components to ensure safe and effective operation as a PACS for teleradiology services.
Technological Characteristics
System architecture includes Capture, Server, and Viewer components. Operates on general-purpose computing hardware. Connectivity via network/web browser. Supports DICOM standard. Software-based image rendering and management. No specific materials or energy sources defined beyond standard IT infrastructure.
Indications for Use
Indicated for use in hospitals, imaging centers, nursing homes, and radiologist reading practices to manage, store, and display DICOM images, scheduling data, and reports. Contraindicated for primary interpretation of lossy compressed mammographic images and digitized film screen images. Mammographic interpretation requires FDA-approved 5 Mpixel resolution monitors.
Regulatory Classification
Identification
A medical image management and processing system is a device that provides one or more capabilities relating to the review and digital processing of medical images for the purposes of interpretation by a trained practitioner of disease detection, diagnosis, or patient management. The software components may provide advanced or complex image processing functions for image manipulation, enhancement, or quantification that are intended for use in the interpretation and analysis of medical images. Advanced image manipulation functions may include image segmentation, multimodality image registration, or 3D visualization. Complex quantitative functions may include semi-automated measurements or time-series measurements.
Special Controls
*Classification.* Class II (special controls; voluntary standards—Digital Imaging and Communications in Medicine (DICOM) Std., Joint Photographic Experts Group (JPEG) Std., Society of Motion Picture and Television Engineers (SMPTE) Test Pattern).
{0}------------------------------------------------
Image /page/0/Picture/0 description: The image shows the logo for New Mexico Economic Development. The logo consists of a stylized evergreen tree on the left, followed by the words "New Mexico" in a bold, sans-serif font. The words "Economic Development" are to the right of "New Mexico" in a smaller font. The text is somewhat blurry.
OCT 1 5 2008
# 510(k) Summary
(in accordance with 21 CFR 807.92)
510(k) Number K_O&236
#### I. Applicant Information
| Applicant: | NEW MEXICO SOFTWARE INC.<br>5021 Indian School Road NE, Suite 100<br>Albuquerque, NM 87110<br>U.S.A. |
|----------------------------|----------------------------------------------------------------------------------------------------------------------------------|
| Contact Person: | Rafael Rubio<br>Technology & Development Vice President<br>Tel: (505) 255-1999<br>Fax: (505) 255-7201<br>e-mail: rafael@nmxs.com |
| Application Correspondent: | EMERGO GROUP INC.<br>1705 S. Capital of Texas Hwy., Suite 500<br>Austin, TX 78746<br>U.S.A. |
| Contact Person: | Neal Kolber<br>Project Manager<br>Tel: (512) 327-9997<br>Fax: (512) 327-9998<br>e-mail: neal@emergogroup.com |
| Date Prepared: | August 5, 2008 |
Device Name and Classification
| Proprietary Name: | XR-EXpress |
|-----------------------|------------------------------------------------|
| Common/Usual Name: | Soft-copy reading and acquisition system |
| Classification Name: | Picture Archiving Communications System (PACS) |
| Regulation Number: | 892.2050 |
| Product Codes: | LLZ |
| Classification: | Class II |
| Classification Panel: | Radiology Devices |
Traditional 510(k) -- XR-EXpress
II.
CONFIDENTIAL
{1}------------------------------------------------
Image /page/1/Picture/0 description: The image shows the logo for New Mexico. The logo consists of a stylized Zia symbol on the left, followed by the word "New Mexico" in a sans-serif font. The Zia symbol is a sun symbol that represents the four cardinal directions, the four seasons, and the four stages of life. The logo is simple and recognizable, and it is often used on official documents and websites.
#### III. Predicate Device
The XR-EXpress device is substantially equivalent to the following FDA cleared predicate device with regard to indications for use, performance and technological characteristics:
| 510(k) Number: | K063221 |
|----------------------|------------------------------------------------|
| Trade Name: | Advanced 3D Web PACS TM |
| Manufacturer: | Nexsys Electronics, Inc. DBA Medweb LLC |
| Common/Usual Name: | Soft-copy reading and acquisition system |
| Classification Name: | Picture Archiving Communications System (PACS) |
| Regulation Number: | 892.2050 |
| Product Codes: | LLZ |
| Classification: | Class II |
#### IV. Description and Intended Use of the Device
XR-EXpress is a PACS and teleradiology system used to receive DICOM images, scheduling information and textual reports, organize and store them in an internal format, and to make that information available across a network via web and customized user interfaces. XR-EXpress is for hospitals, imaging centers, nursing homes, radiologist reading practices, and any user who requires and is granted access to patient image, demographic, and report information.
Lossy compressed mammographic images and digitized film screen images must not be reviewed for primary image interpretations. Mammographic images may only be interpreted using an FDA approved monitor that offers at least 5 Mpixel resolution and meets other technical specifications reviewed and accepted by FDA. Moreover, it is the user's responsibility to ensure monitor quality, ambient light conditions, and image compression ratios are consistent with the clinical application.
The software does not contact the patient, nor does it control any lifesustaining devices. A physician has ample opportunity for competent human intervention while interpreting images and clinical information.
#### V. Summary of the Technical Characteristics
The XR-EXpress system is comprised of a capture component (XR-EXpress Capture), a central server component (XR-EXpress Server), and a viewer component (XR-EXpress Viewer) that is used on general purpose computing hardware. Patient information, procedure information, and image acquisition data is captured by XR-EXpress Capture and sent to the XR-EXpress server or
CONFIDENTIAL Traditional 510(k) - XR-EXpress
{2}------------------------------------------------
Image /page/2/Picture/0 description: The image shows the New Mexico state logo. The logo consists of a stylized Zia symbol on the left, followed by the words "New Mexico" in a sans-serif font. To the right of the state name are some blurred words.
alternatively, it is accepted directly from a DICOM compliant device. After receiving image objects and associated data, the XR-EXpress server registers the incoming data and images with the archive including any associations with prior cases. The cases are presented to users with the correct permissions from a work list as controlled by a managing user. The image data is transmitted and rendered on the users workstation using a standard web browser for management views or the XR-EXpress Viewer for diagnosis. After using the workstation to view the images, the user optionally dictates a report into the system, after which, a user can play back the dictation and transcribe it to text. Once the XR-EXpress Server registers a report, the report is available to the referring physician or client service where it available electronically or via fax.
#### VI. Testing
New Mexico Software has conducted extensive validation testing of the XR-EX System, as a PACS system that is capable of providing reliable teleradiology services over the Internet. All of the different components of the XR-EX system have been stress tested to ensure that the system as a whole provides all the capabilities necessary to operate safely and effectively.
#### VII. Safety & Effectiveness Conclusions
Based on the intended use and technological characteristics, the XR-EXpress system is substantially equivalent to the Advanced 3D Web PACSTM device manufactured by Nexsys Electronics, Inc. DBA Medweb LLC (K063221). The XR-EXpress raises no new safety or effectiveness issues.
{3}------------------------------------------------
### DEPARTMENT OF HEALTH & HUMAN SERVICES
Image /page/3/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a stylized caduceus symbol, which is a staff with two snakes coiled around it, topped by a pair of wings. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES USA" is arranged in a circular fashion around the symbol.
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
### OCT 1 5 2008
New Mexico Software, Inc. % Mr. Neal Kolber Project Manager Emergo Group, Inc. 1705 S. Capital of Texas Hwy., Suite 500 AUSTIN TX 78746
Re: K082336
Trade/Device Name: XR-EXpress Regulation Number: 21 CFR 892.2050 Regulation Name: Picture archiving and communications system Regulatory Class: II Product Code: LLZ Dated: August 5, 2008 Received: August 15, 2008
Dear Mr. Kolber:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
{4}------------------------------------------------
### Page 2
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (OS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at one of the following numbers, based on the regulation number at the top of this letter:
| 21 CFR 876.xxx | (Gastroenterology/Renal/Urology) | 240-276-0115 |
|----------------|----------------------------------|--------------|
| 21 CFR 884.xxx | (Obstetrics/Gynecology) | 240-276-0115 |
| 21 CFR 894.xxx | (Radiology) | 240-276-0120 |
| Other | | 240-276-0100 |
Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding postmarket surveillance, please contact CDRH's Office of Surveillance and Biometrics' (OSB's) Division of Postmarket Surveillance at 240-276-3474. For questions regarding the reporting of device adverse events (Medical Device Reporting (MDR)), please contact the Division of Surveillance Systems at 240-276-3464. You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (240) 276-3150 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html.
Sincerely vours.
hope M. Whang
Joyce M. Whang, Ph.D. Acting Director, Division of Reproductive, Abdominal, and Radiological Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{5}------------------------------------------------
Image /page/5/Picture/0 description: The image shows the words "New Mexico" in a stylized font. To the left of the words is a symbol that looks like a stylized pine tree. The words "Department of Health" are written in a smaller font to the right of "New Mexico."
## 4. Indication for Use Statement
510(k) Number (if known):
K082326
Device Name:
XR-EXpress
Indications for Use:
XR-EXpress is a PACS and teleradiology system used to receive DICOM images. scheduling information and textual reports, organize and store them in an internal format, and to make that information available across a network via web and customized user interfaces. XR-EXpress is for hospitals, imaging centers, nursing homes, radiologist reading practices, and any user who requires and is granted access to patient image, demographic, and report information.
Lossy compressed mammographic images and digitized film screen images must not be reviewed for primary image interpretations. Mammographic images may only be interpreted using an FDA approved monitor that offers at least 5 Mpixel resolution and meets other technical specifications reviewed and accepted by FDA.
Prescription Use X (Part 21 CFR 801 Subpart D) AND/OR
Over-The-Counter Use (21 CFR 801 Subpart C)
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Helena
Page 1 of
(Division Sign-Off) Division of Reproductive, Abdominal and Radiological Devices 510(k) Number
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Guidance alerts
New and changed FDA guidance documents, emailed as a daily digest.
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the ? button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only Software as a Medical Device, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (Software as a Medical Device), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.