← Product Code [QPB](/productcode/QPB) · K082025

# BODY-JET (K082025)

_Human Med AG · QPB · Aug 13, 2008 · General, Plastic Surgery · SESE_

**Canonical URL:** https://fda.innolitics.com/device/K082025

## Device Facts

- **Applicant:** Human Med AG
- **Product Code:** [QPB](/productcode/QPB.md)
- **Decision Date:** Aug 13, 2008
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 878.5040
- **Device Class:** Class 2
- **Review Panel:** General, Plastic Surgery
- **Attributes:** Therapeutic, Real-World Evidence, 3rd-Party Reviewed

## Real-World Evidence

| Submission | Device | Sponsor | RWD Sources | RWE Use Summary | Key Tags |
| --- | --- | --- | --- | --- | --- |
| K082025 · Aug 13, 2008 | BODY-JET | Human Med AG | Published clinical performance data | The sponsor utilized published clinical performance data to demonstrate that the body-jet device is as safe and effective as its predicate devices for aesthetic body contouring. | clinical literature; aesthetic body contouring; performance data |

### Clinical Evidence

| Study Design | Population | Comparator | Key Endpoints |
| --- | --- | --- | --- |
| Published clinical performance data | Patients undergoing aesthetic body contouring | Not applicable for this study | Safety and effectiveness for aesthetic body contouring |

## Indications for Use

Aesthetic body contouring

## Device Story

Suction lipoplasty system for aesthetic body contouring; removes adipose tissue via negative pressure. System includes powered vacuum pump (double piston, 1/3 HP), collection bags with overflow/bacterial filters, and proprietary WAL Applicator (single-use tubing set with infiltration pump). Infiltration pump delivers saline to tissue area via irrigation cannulae; vacuum pump aspirates loosened fat. Used in clinical settings by physicians. Benefits include tissue-sparing fat removal; fan-shaped saline spray loosens adipose tissue while preserving connective tissue, muscle, blood vessels, and nerves.

## Clinical Evidence

No prospective clinical trials were conducted. Evidence consists of in-vitro laboratory investigations on human cadaveric and excised abdominal fat tissue to assess the impact of the fan-shaped saline spray on adipose, connective, muscle, vascular, and nerve tissues. Additionally, the submission relies on a review of published clinical performance data for the device and predicate lipoplasty techniques to support safety and effectiveness claims.

## Technological Characteristics

Powered vacuum pump with two WOB-L pistons; variable vacuum range 0-26.5 inHg. Includes overflow/bacterial filters, single-use WAL Applicator tubing, and re-sterilizable proprietary cannulae. System uses dynamic compression via fixed pistons. Infiltration pump delivers saline for tissue preparation. Materials and design are equivalent to predicate suction/infiltration systems.

## Regulatory Identification

A suction lipoplasty system is a device intended for aesthetic body contouring. The device consists of a powered suction pump (containing a microbial filter on the exhaust and a microbial in-line filter in the connecting tubing between the collection bottle and the safety trap), collection bottle, cannula, and connecting tube. The microbial filters, tubing, collection bottle, and cannula must be capable of being changed between patients. The powered suction pump has a motor with a minimum of 1/3 horsepower, a variable vacuum range from 0 to 29.9 inches of mercury, vacuum control valves to regulate the vacuum with accompanying vacuum gauges, a single or double rotary vane (with or without oil), a single or double diaphragm, a single or double piston, and a safety trap.

## Special Controls

*Classification.* Class II (special controls). Consensus standards and labeling restrictions.

## Predicate Devices

- Liposat® Power Infiltration Pump (Model 00002274) ([K053451](/device/K053451.md))
- Dominant 50 Lipo Powered Suction Pump ([K063336](/device/K063336.md))
- Byron Medical Infiltration and Aspiration Cannulae and Needles ([K981172](/device/K981172.md))

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

Image /page/0/Picture/0 description: The image contains the logo of the U.S. Food and Drug Administration (FDA). On the left is the Department of Health & Human Services logo. To the right of that is the FDA logo, which is a blue square with the letters "FDA" in white. To the right of the blue square is the text "U.S. FOOD & DRUG ADMINISTRATION" in blue.

Human Med Ag % Tuv Sud America Inc. Stefan Preiss 1775 Old Highway 8 NW New Brighton, Minnesota 55112-1891

June 8, 2021

Re: K082025

Trade/Device Name: Body-Jet Regulation Number: 21 CFR 878.5040 Regulation Name: Suction lipoplasty system Regulatory Class: Class II Product Code: QPB

Dear Stefan Preiss:

The Food and Drug Administration (FDA) is sending this letter to notify you of an administrative change related to your previous substantial equivalence (SE) determination letter dated August 13, 2008. Specifically, FDA is updating this SE Letter because FDA has created a new product code to better categorize your device technology.

Please note that the 510(k) submission was not re-reviewed. For questions regarding this letter please contact Cindy Chowdhury, OHT4: Office of Surgical and Infection Control Devices, 240-402-6647, Cindy.Chowdhury@fda.hhs.gov.

Sincerely,

# Cindy Chowdhury -S

Cindy Chowdhury, Ph.D., M.B.A. Assistant Director DHT4B: Division of Infection Control and Plastic Surgery Devices OHT4: Office of Surgical and Infection Control Devices Office of Product Evaluation and Quality Center for Devices and Radiological Health

{1}------------------------------------------------

Image /page/1/Picture/1 description: The image shows the seal of the U.S. Department of Health & Human Services. The seal features the department's name in a circular arrangement around a stylized emblem. The emblem consists of a staff with a snake entwined around it, which is a symbol of medicine and healing.

Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850

Human Med AG % TUV SUD America, Inc. Stefan Preiss 1775 Old Highway 8 NW New Brighton, Minnesota 55112

AUG 1 3 2008

Re: K082025

Trade/Device Name: body-jet® Regulation Number: 21 CFR 878.5040 Regulation Name: Suction lipoplasty system Regulatory Class: II Product Code: MVV Dated: July 28, 2008 Received: July 30, 2008

Dear Stefan Preiss:

We have res iewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food. Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.

{2}------------------------------------------------

#### Page 2 - Stefan Preiss

This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Center for Devices and Radiological Health's (CDRH's) Office of Compliarice at (240) 276-0115. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding postmarket surveillance, please contact CDRH's Office of Surveillance and Biometric's (OSB's) Division of Postmarket Surveillance at (240) 276-3474. For questions regarding the reporting of device adverse ventually (Medical Device Reporting (MDR)), please contact the Division of Surveillance Systems at (240) 276-3464. You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (240) 276-3150 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html.

Sincerely yours,

Mark M. Millman

Mark N. Melkerson Director Division of General, Restorative and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{3}------------------------------------------------

# Indications for Use Statement

KOSTOTE 510(k) Number (if known): body-jet® Device Name: _________________________________________________________________________________________________________________________________________________________________

Indications for Use:

Aesthetic body contouring

(Division Sign-Off)
Division of General, Restorative,
and Neurological Devices

**510(k) Number** k082018

Prescription Use Over-the-Counter Use yes no AND/OR (Part 21 CFR 801 Subpart D) (21 CFR 801 Subpart C)

> 00041 0-0-0-0-0-0

{4}------------------------------------------------

Section 5 -- 510(k) Summary

K082025 page 1/3

# AUG 1 3 2008

# This 510(k) Summary for body-jet® meets the requirements of 21 CFR § 807.92

### 1. Submitter Information

Human Med AG Wilhelm-Hennemann-Strasse 9 D-19061 Schwerin Germany

Contact Person:

Inge Matthiesen c/o Human Med AG Wilhelm-Hennemann-Strasse 9 D-19061 Schwerin Germany

| Phone: | +49(0)385 395 70-0  |
|--------|---------------------|
| Fax:   | +49(0)385 395 70-29 |

- 2. Name of Device:

| Common name:         | Suction Lipoplasty System                              |
|----------------------|--------------------------------------------------------|
| Proprietary name:    | body-jet®                                              |
| Classification:      | Suction Lipoplasty System, Class II, 21 CFR § 878.5040 |
| Product code:        | MUU                                                    |
| Indications for use: | Aesthetic body contouring                              |

## 3. Name of the predicate device(s)

- Liposat® Power Infiltration Pump (Model 00002274) . Moeller Medical GmbH & Co. KG (K053451)
- Dominant 50 Lipo Powered Suction Pump, . Medela AG (K063336)
- Byron Medical Infiltration and Aspiration Cannulae and Needles . Byron Medical, Inc. (K981172)

{5}------------------------------------------------

K082025 Page 2/3

#### 4. Device Description

The body-jet®, a suction lipoplasty system, is a device intended for aesthetic body contouring. The device consists of a powered vacuum pump (containing an overflow/bacterial filter in the tube between the vacuum pump and suction bag), a collection bag with integrated overflow/bacterial filter, cannulae, and a connecting tube. The suction/collection bags including bacterial filters, the tubing, and the cannulae are to be changed between patients. The powered vacuum pump has a motor with a minimum of 1/3 horsepower, a variable vacuum range from 0 to 26.5 inches of mercury, vacuum control valve to regulate the vacuum with accompanying vacuum gauge, a double piston, and a safety trap. The powered vacuum pump generates a negative pressure for the removal of fat or adipose tissue from distinct body-fat deposits for aesthetic body-contouring.

The body-jet® includes a sterile, single-use tubing set with a small infiltration pump (the WAL Applicator), which transports the saline for the infiltration of the tissue area to be treated, and infiltration and irrigation cannulae. The single-use tubing set (WAL Applicator) and the reusable cannulae have been designed as proprietary products.

#### 5. Indications for Use

The body-jet® is intended for aesthetic body contouring.

#### 6. Summary of Technological Characteristics

The body-jet® vacuum pump system consists of a powered vacuum pump with two WOB-L pistons (dynamic compression by fixed piston inside cylinder) working bit-parallel in the punp. The powered vacuum pump generates a negative pressure for the removal of adipose tissue. Two suction containers of identical design and mode of operation, one on the left side and one on the right side of the body-jet® device, are provided for holding the suction bags.

The suction bags are equipped with a dual-function filter acts simultaneously as an overflow protection and a bacterial barrier and closes automatically when it contact with fluids. The connecting tube between the collection bag and the vacuum pump contains an overflow protection/bacterial filter. It is used when the dual filter in the suction bag is damaged. If the fluid reaches a maximum level in the bag, the floats in the overflow filter will block the inlet port, automatically stopping the suction. This prevents the back-up of fluid to either the pump or the patient. The tubing is able to withstand the amount of negative pressure created by the vacuum pump without collapsing.

A small infiltration pump (included in the single-use WAL Applicator) transports the saline for the infiltration of the treated tissue area via the infiltration cannulae, similar to the procedure of traditional liposuction and of its predicate devices. The WAL Applicator has been designed as a single-use proprietary product. The cannulae are re-sterilizable proprietary products.

The vacuum pump system, the infiltration pump system and the cannulae of the body-jet® are substantially equivalent to the vacuum and infiltration pump systems, and the cannulae of its predicate devices in terms of intended use, design, operating principles, and materials.

{6}------------------------------------------------

K082025 page 3/3

#### 7. Summary of Histopathological and Immunohistological Performance Data

In order to support a determination of safety and effectiveness, the effect of the fan-shaped saline spray of the body-jet® has been studied on different human tissue structures. For this purpose two in-vitro laboratory investigations have been carried out. on fat tissue samples from human corpses (Investigation 1), and from "dead" abdominal fat excisates (Investigation 2). No humans have been treated for the purpose of these in-vitro laboratory investigations.

The following tissue structures were examined: :

- . adipose tissue,
- connective tissue, �
- muscle tissue, .
- . blood vessels.
- nerves. .

Based on the results of these investigations (please refer to Section 18) it can be summarized that water assisted lipoplasty with the fan-shaped water spray of the body-jet" produces no damage to vital structures like connective tissue, muscle tissue, blood vessels and nerves, thus supporting a determination of safety and substantial equivalence of the body-jet® water-assisted technique WAL to its predicate devices and the other referenced lipoplasty techniques.

#### 8. Summary of Clinical Performance Data

The evaluation of published clinical performance data demonstrate that the body-jet" device is as safe, as effective, and performs as well as its predicate devices and the other referenced lipoplasty techniques that are currently cleared for aesthetic body contouring.

Based on the results of the published clinical performance data (as presented in Section 20) and the pathohistological performance data (as presented in Section 18) it can be summarized that water assisted lipoplasty with the fan-shaped water spray of the body-jet® loosens the adipose tissue, and separates and aspirates the adipocytes without producing any damage to vital structures like connective tissue, muscle tissue, blood vessels and nerves, thus supporting a determination of safety and effectiveness, and substantial equivalence of the body-jef waterassisted technique (WAL) to its predicate devices and the other referenced lipoplasty techniques.

#### 9. Conclusion

Based upon the information presented above and in this 510(k) submission , it is concluded that the proposed body-jet® is substantially equivalent to its predicate devices, and safe and effective for the intended use of aesthetic body contouring.

---

**Source:** [https://fda.innolitics.com/device/K082025](https://fda.innolitics.com/device/K082025)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
