IDI IMPLANT SYSTEM
Device Facts
| Record ID | K081806 |
|---|---|
| Device Name | IDI IMPLANT SYSTEM |
| Applicant | Idi Biomedical, LLC |
| Product Code | DZE · Dental |
| Decision Date | Nov 7, 2008 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 872.3640 |
| Device Class | Class 2 |
| Attributes | Therapeutic |
Indications for Use
IDI Implant System are endosseous implants intended to be surgically placed in the bone of the upper or lower jaw arches to provide support for prosthetic devices, such as an artificial tooth, in order to restore patient esthetics and chewing function. Straight abutments indicated for both screw retained and cemented restorations are included. The implants are indicated for single or multiple unit restorations and can be used in splinted and nonsplinted applications. The device is intended for immediate loading when good primary stability has been achieved and with appropriate occlusal loading.
Device Story
IDI Implant Systems are threaded root-form dental implants and straight abutments; surgically placed in upper or lower jaw bone; provide support for prosthetic devices (artificial teeth). Used by dental clinicians to restore esthetics and chewing function in edentulous patients. Supports single/multiple unit restorations; splinted/non-splinted applications; allows immediate loading given sufficient primary stability. Restorative options include screw-retained or cemented restorations.
Clinical Evidence
No clinical data provided; bench testing only.
Technological Characteristics
Threaded root-form endosseous dental implants and straight abutments. Materials and design are consistent with standard dental implant technology for jaw bone integration. No software or electronic components.
Indications for Use
Indicated for partially or fully edentulous patients requiring single or multiple unit dental restorations in the upper or lower jaw. Supports prosthetic devices for esthetics and chewing function. Suitable for splinted or non-splinted applications and immediate loading when primary stability is achieved.
Regulatory Classification
Identification
An endosseous dental implant is a prescription device made of a material such as titanium or titanium alloy that is intended to be surgically placed in the bone of the upper or lower jaw arches to provide support for prosthetic devices, such as artificial teeth, in order to restore a patient's chewing function.
Special Controls
*Classification.* (1) Class II (special controls). The device is classified as class II if it is a root-form endosseous dental implant. The root-form endosseous dental implant is characterized by four geometrically distinct types: Basket, screw, solid cylinder, and hollow cylinder. The guidance document entitled “Class II Special Controls Guidance Document: Root-Form Endosseous Dental Implants and Endosseous Dental Implant Abutments” will serve as the special control. (See § 872.1(e) for the availability of this guidance document.)(2) *Classification.* Class II (special controls). The device is classified as class II if it is a blade-form endosseous dental implant. The special controls for this device are:(i) The design characteristics of the device must ensure that the geometry and material composition are consistent with the intended use; (ii) Mechanical performance (fatigue) testing under simulated physiological conditions to demonstrate maximum load (endurance limit) when the device is subjected to compressive and shear loads; (iii) Corrosion testing under simulated physiological conditions to demonstrate corrosion potential of each metal or alloy, couple potential for an assembled dissimilar metal implant system, and corrosion rate for an assembled dissimilar metal implant system; (iv) The device must be demonstrated to be biocompatible; (v) Sterility testing must demonstrate the sterility of the device; (vi) Performance testing to evaluate the compatibility of the device in a magnetic resonance (MR) environment; (vii) Labeling must include a clear description of the technological features, how the device should be used in patients, detailed surgical protocol and restoration procedures, relevant precautions and warnings based on the clinical use of the device, and qualifications and training requirements for device users including technicians and clinicians; (viii) Patient labeling must contain a description of how the device works, how the device is placed, how the patient needs to care for the implant, possible adverse events and how to report any complications; and (ix) Documented clinical experience must demonstrate safe and effective use and capture any adverse events observed during clinical use.
Predicate Devices
- NobelReplace Hexagonal Implant (K073142)