MONOJECT HYPODERMIC NEEDLE, MODEL 250, 30 GAUGE HYPODERMIC NEEDLE
K073122 · Covidien Lp, Formerly Registered AS Tyco Healthcar · FMI · Nov 21, 2007 · General Hospital
Device Facts
Record ID
K073122
Device Name
MONOJECT HYPODERMIC NEEDLE, MODEL 250, 30 GAUGE HYPODERMIC NEEDLE
Applicant
Covidien Lp, Formerly Registered AS Tyco Healthcar
Product Code
FMI · General Hospital
Decision Date
Nov 21, 2007
Decision
SESE
Submission Type
Abbreviated
Regulation
21 CFR 880.5570
Device Class
Class 2
Attributes
Therapeutic
Indications for Use
The proposed devices are intended for the injection of medications into or the withdrawal of body fluids from parts of the body below the surface of the skin.
Device Story
Single-use, disposable hypodermic needle; consists of sharpened metal tube attached to female hub; connects to male nozzle of piston syringe or intravascular administration set. Used by clinicians for medication injection or fluid withdrawal. Simple mechanical device; no electronic or software components.
Clinical Evidence
Bench testing only. Device conforms to FDA-recognized consensus standards for needles, including ISO 7864, ISO 9626, ISO 594-1, ISO 594-2, and ISO 6009.
Technological Characteristics
Single-use, disposable hypodermic needle. Metal tube with sharpened tip and female hub connector. Conforms to ISO 7864, ISO 9626, ISO 594-1, ISO 594-2, and ISO 6009. No software or electronic components.
Indications for Use
Indicated for injection of medications or withdrawal of body fluids from subcutaneous or deeper body tissues. No specific age or gender restrictions provided.
Regulatory Classification
Identification
A hypodermic single lumen needle is a device intended to inject fluids into, or withdraw fluids from, parts of the body below the surface of the skin. The device consists of a metal tube that is sharpened at one end and at the other end joined to a female connector (hub) designed to mate with a male connector (nozzle) of a piston syringe or an intravascular administration set.
{0}------------------------------------------------
K073122 p.lot/
510(k) Premarket Notification 30 Gauge Monoject® Hypodermic Needles
## Section H - 510(k) Summary
| Date Summary<br>Was Prepared: | September 17, 2007 |
|----------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Contact Person: | Debora Stapleton<br>Regulatory Affairs<br>Covidien LP (formerly registered as Tyco Healthcare Group LP)<br>15 Hampshire Street<br>Mansfield, MA 02048<br>Telephone: 508-452-4866<br>Fax: 508-261-8461<br>NOV 21 2007 |
| Device Trade<br>Name: | MONOJECT® 30 Gauge Hypodermic Needles, Regular and Thin Wall |
| Device Common<br>Name: | Needle, Hypodermic, Single Lumen |
| FDA Product Code: | FMI, 21 CFR 880.5570 |
| Classification Panel: General Hospital | |
Legally Marketed Devices to Which Substantial Equivalence Is Claimed:
- MONOJECT® Sterile M250 Hypodermic Needles, K854547 s
- TERUMO® 30 Gauge Hypodermic Needle, K012646
Device Intended Use: The proposed devices are intended for the injection of medications into or the withdrawal of body fluids from parts of the body below the surface of the skin.
Device Description: The devices consist of a metal tube that is sharpened at one end and at the other end joined to a female connector (hub) designed to mate with a male connector (nozzle) of a piston syringe or an intravascular administration set.
Summary of Technological Characteristics: The proposed single use, disposable devices have the same technological characteristics as the predicate devices. The devices conform to FDA recognized safety and performance consensus standards for needles, including ISO 7864, ISO 9626, ISO 594-1, ISO 594-2, and ISO 6009.
The MONOJECT® 30 Gauge hypodermic needles with lengths ranging from 5/16" to 1-1/2" are of the same design and intended use to that of the predicate devices. They are meant as an extension to the MONOJECT® needle product line.
{1}------------------------------------------------
Image /page/1/Picture/1 description: The image shows the seal of the Department of Health and Human Services (HHS). The seal features a stylized eagle with three stripes representing health, human services, and well-being. The words "DEPARTMENT OF HEALTH AND HUMAN SERVICES - USA" are arranged in a circular pattern around the eagle.
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
NOV 2 1 2007
Ms. Debora Stapleton Senior Regulatory Affairs Specialist Covidien LP 15 Hampshire Street Mansfield, Masachusett 02048
Re: K073122
Trade/Device Name: 30 Gauge MONOJECT® Hypodermic Needles, Regular and Thin Wall Regulation Number: 21 CFR 880.5570 Regulation Name: Hypodermic Single Lumen Needle Regulatory Class: II Product Code: FMI Dated: October 31, 2007 Received: November 6, 2007
Dear Ms. Stapleton:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
{2}------------------------------------------------
## Page 2 - Ms. Stapleton
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (OS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at (240) 276-0115. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807,97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (240) 276-3150 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html.
Sincerely yours,
Susan Hwang
Chiu Lin, Ph.D. Director Division of Anesthesiology, General Hospital, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health
## Enclosure
{3}------------------------------------------------
510(k) Premarket Notification 30 Gauge Monoject® Hypodermic Needles
## Indications for Use
510(k) Number (if known): K073122
30 Gauge MONOJECT® Hypodermic Needles, Regular and Device Name: Thin Wall
Indications For Use:
These devices are intended for the injection of medications into or the withdrawal of body fluids from parts of the body below the surface of the skin.
Prescription Use J (Part 21 CFR 801 Subpart D)
.
AND/OR
Over-The-Counter Use (21 CFR 801 Subpart C)
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Arntzen
Page 1 of ____________________________________________________________________________________________________________________________________________________________________
(Division Sign-Off) Division of Anesthesiology, General Hospital Infection Control, Dental Devices
510(k) Number: 大�7312 3_
Panel 1
/
Ready
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches