← Product Code [NEY](/productcode/NEY) · K072687

# VALLEYLAB MICROWAVE ABLATION GENERATOR (K072687)

_Covidien Lp, Formerly Know AS Valleylab, A Divison · NEY · Nov 25, 2008 · General, Plastic Surgery · SESE_

**Canonical URL:** https://fda.innolitics.com/device/K072687

## Device Facts

- **Applicant:** Covidien Lp, Formerly Know AS Valleylab, A Divison
- **Product Code:** [NEY](/productcode/NEY.md)
- **Decision Date:** Nov 25, 2008
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 878.4400
- **Device Class:** Class 2
- **Review Panel:** General, Plastic Surgery
- **Attributes:** Therapeutic

## Indications for Use

The Valleylab Microwave Ablation Generator is intended for use in percutaneous, laparoscopic, and intraoperative coagulation (ablation) of soft tissue, including partial or complete ablation of non-resectable liver tumors. The MW Ablation Generator is not intended for use in cardiac procedures

## Device Story

Valleylab Microwave Ablation Generator provides microwave power for soft tissue ablation. System includes generator, proprietary microwave antennas, and cooling pump for circulating sterile saline to percutaneous antennas. Physician operates generator via front panel controls to set power (up to 60W) and duration; display shows power, duration, and elapsed time. Antennas are placed directly into tissue; energy radiates to induce coagulation. Used in percutaneous, laparoscopic, or intraoperative settings. Output affects tissue necrosis; clinical benefit includes treatment of non-resectable liver tumors. System firmware manages power delivery and error codes.

## Clinical Evidence

No new clinical trials conducted. Evidence relies on a review of existing studies demonstrating clinical safety and effectiveness for liver tumor ablation. Bench testing included bovine liver studies and in-vivo porcine liver studies comparing ablation size and geometry against the Cool-tip RF System. Additional testing included thermal profile, performance, vascular proximity evaluation, and safety standard compliance.

## Technological Characteristics

Operates at 915 MHz; max power 60 W. Components: generator, pump, sterile tubing, and insulated stainless steel antennas (3.7cm active length). Percutaneous antennas are internally cooled via saline; surgical antennas are not. Connectivity: standalone. Firmware-controlled power delivery and error monitoring. Sterilization: antennas provided sterile.

## Regulatory Identification

An electrosurgical cutting and coagulation device and accessories is a device intended to remove tissue and control bleeding by use of high-frequency electrical current.

## Predicate Devices

- VivaWave Microwave System ([K011676](/device/K011676.md))
- Cool-tip™ RF System ([K053290](/device/K053290.md))

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

\$\omega\$ 72687

Page 1 of 3

## 510(k) Summary or 510(k) Statement

510(k) Summary

1. Submitter Information: NOV 2 5 2008

Covidion

Energy-based Devices Formerly known as Valleylab, a Division of Tyco Healthcare LP 5920 Longbow Drive Boulder, CO Contact: Philip E. Ake Senior Regulatory Associate Phone: 303-581-6934 Fax: 303-230-6313 Email: Philip.Ake@Covidien.com

2. Name of Device

Trade name: Valleylab Microwave Ablation Generator Common/Classification name: Electrosurgical cutting and coagulation device and accessories (21 CFR 878.4400)

3. Predicate Devices

The Valleylab Microwave Ablation Generator is substantially equivalent to the following legally marketed medical devices:

- VivaWave Microwave System (K011676) ●
- Cool-tip™ RF System (K053290) .

Device Description 4.

The Valleylab Microwave Ablation Generator is designed to provide microwave power for the ablation of soft tissue in medical procedures. It was cleared for commercial distribution (K011676) by demonstrating substantial equivalence to existing Radiofrequency and Microwave Ablation systems.

The Microwave Ablation Generator is designed to be used with proprietary microwave antennas (cleared in K011676 and K032702) which are placed directly into the tissue to be ablated. The Valleylab Microwave Ablation Generator is a nonsterile electrical device that is not intended to contact the patient.

The Microwave Ablation Generator is used with a pump to circulate cooling fluid (sterile saline) to the antennas, and an optional integrated cart. The device's power output and duration (time) are controlled by the user via manual controls on the front

{1}------------------------------------------------

|co72687

Page 2 of 3

panel of the generator. The display on the front of the device shows power (watts), duration of power delivery (minutes and seconds), and elapsed time.

The antenna is connected to the generator and radiates power to the tissue under treatment. The antennas are provided sterile, for single use only. The shaft of each antenna is made of insulated stainless steel. Three antennas of different lengths are available for use in percutaneous procedures, and a single length antenna fing surgical procedures. The active portion of the antenna is 3.7cm in length for all models. The percutaneous antennas are cooled by circulating sterile saline through the antenna. The surgical antennas are not internally cooled. The system pump circulates fluid from a reservoir to the antenna through sterile tubing. Sterile fluid is confined within the antenna and tubing, and does not contact the patient.

5. Intended Use

The Valleylab Microwave Ablation Generator is intended for use in percutaneous, laparoscopic, and intraoperative coagulation (ablation) of soft tissue, including partial or complete ablation of non-resectable liver tumors.

The MW Ablation Generator is not intended for use in cardiac procedures

6. Summary of Technology Characteristics

The Valleylab Microwave Ablation Generator operates at 915 MIIZ. The generator is capable of operating up to 60 W. The amount of power delivered depends on the antenna used and is controlled by the generator firmware. The user has the ability to select the desired power and time limits within the system specifications. The generator firmware is responsible for the system error codes.

The technological characteristics of the Valleylab Microwave Ablation generator are not being modified; this 510(k) is for a change to the intended use of the device.

The original Intended Use of the MW Ablation generator was for use on soft tissue. This submission expands the intended use to include partial or complete ablation of non-resectable liver tumors. The Cool-tip generator intended use includes ablation of liver tumors.

7. Summary Non-clinical testing

Bench Testing was conducted on bovine livers and in-vivo testing on porcine livers to compare the ablation size and geometry of lesions created by the Microwave Ablation Generator and the Cool-tip™ RF System. The testing included single and multiple antenna comparisons. The lesions were evaluated histologically and physically. The testing revealed that in some instances there was a difference in lesion size. However, the lesions that are generated by both systems have similar pathologic and imaging characteristics.

{2}------------------------------------------------

Ko7 2687

Page 3 of 3

Other testing included: thermal profile testing, performance testing, evaluation of ablation characteristics next to vasculature, an evaluation of the device to the current versions of the relevant safety standards, and software testing.

8. Summary of Clinical testing

A review of the existing studies have shown that the use of the system to be clinically safe and effective for ablation of liver tumors.

{3}------------------------------------------------

Image /page/3/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a stylized caduceus symbol, which is a staff with two snakes coiled around it, and the text "DEPARTMENT OF HEALTH & HUMAN SERVICES . USA" arranged in a circular pattern around the symbol. The logo is black and white.

Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850

## NOV 2 5 2008

Covidien, % Mr. Philip E. Ake Senior Regulatory Associate 5920 Longbow Drive Boulder, Colorado 80301-3299

Re: K072687

Trade/Device Name: Valleylab Microwave Ablation Generator Regulation Number: 21 CFR 878.4400 Regulation Name: Electrosurgical cutting and coagulation device and accessories Regulatory Class: II Product Code: NEY Dated: November 14, 2008 Received: November 17, 2008

Dear Mr. Ake:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.

{4}------------------------------------------------

Page 2 - Mr. Philip E. Ake

This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Center for Devices and Radiological Health's (CDRH's) Office of Compliance at (240) 276-0115. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding postmarket surveillance, please contact CDRH's Office of Surveillance and Biometric's (OSB's) Division of Postmarket Surveillance at (240) 276-3474. For questions regarding the reporting of device adverse events. (Medical Device Reporting (MDR)), please contact the Division of Surveillance Systems at (240) 276-3464. You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistances at its toll-free number (800) 638-2041 or (240) 276-3150 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html.

Sincerely yours.

Mark M. Mulhern

Mark N. Melkerson Director Division of General, Restorative and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{5}------------------------------------------------

Ko 72687

## Indications for Use Statement

510(k) Number (if known):

Device Name: Valleylab Microwave Ablation Generator

Indications for Use:

The Valleylab Microwave Ablation Generator is intended for use in percutaneous, laparoscopic, and intraoperative coagulation (ablation) of soft tissue, including partial or complete ablation of non-resectable liver tumors.

Prescription Use X (Part 21 CFR 801 Subpart D)

Over-The-Counter Use AND/OR (21 CFR 801 Subpart C)

(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE OF NEEDED)

Concurrence of CDRH, Office of Device Evaluation (ODE)

Mark A. Williams

(Division Sign-Off) (Division Sign of General, Restorative, Divisionomical Devices

510(k) Number

---

**Source:** [https://fda.innolitics.com/device/K072687](https://fda.innolitics.com/device/K072687)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
