SBI TITANIUM THREADED PIN

K071540 · Small Bone Innovations, Inc. · JDW · Aug 8, 2007 · Orthopedic

Device Facts

Record IDK071540
Device NameSBI TITANIUM THREADED PIN
ApplicantSmall Bone Innovations, Inc.
Product CodeJDW · Orthopedic
Decision DateAug 8, 2007
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 888.3040
Device ClassClass 2
AttributesTherapeutic

Indications for Use

The SBi Titanium Threaded Pin is indicated for bone reconstruction, osteotomy, arthrodesis, joint fusion, fracture repair, and fracture fixation of bones appropriate for the size of the device.

Device Story

SBi Titanium Threaded Pin is an internal bone fixation device. It consists of titanium pins featuring a machined groove for break-away capability. Used by surgeons in clinical settings for bone reconstruction, osteotomy, arthrodesis, joint fusion, and fracture repair/fixation. The device is supplied non-sterile in various diameters and lengths. It provides mechanical stabilization of bone segments to facilitate healing.

Clinical Evidence

No clinical data; bench testing only.

Technological Characteristics

Material: Ti-6Al-4V per ISO 5832-3. Form factor: Threaded pin with machined break-away groove. Supplied non-sterile.

Indications for Use

Indicated for patients requiring bone reconstruction, osteotomy, arthrodesis, joint fusion, fracture repair, or fracture fixation of bones appropriate for the device size.

Regulatory Classification

Identification

A smooth or threaded metallic bone fixation fastener is a device intended to be implanted that consists of a stiff wire segment or rod made of alloys, such as cobalt-chromium-molybdenum and stainless steel, and that may be smooth on the outside, fully or partially threaded, straight or U-shaped; and may be either blunt pointed, sharp pointed, or have a formed, slotted head on the end. It may be used for fixation of bone fractures, for bone reconstructions, as a guide pin for insertion of other implants, or it may be implanted through the skin so that a pulling force (traction) may be applied to the skeletal system.

Submission Summary (Full Text)

{1}------------------------------------------------ ## K671540 p : . ## 510(k) Summary | Manufacturer: | Small Bone Innovations International, SA<br>Z.A. Les Bruyeres<br>Peronnas France 01960 | AUG - 8 2007 | |--------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------| | Submitted By: | Small Bone Innovations<br>1380 South Pennsylvania Avenue<br>Morrisville, PA 19067 | | | Proprietary Name: | SBi Titanium Threaded Pin | | | Classification name: | Class II, 888.3040 - Smooth or threaded metallic bone<br>fixation fastener | | | Common/Usual Name: | Pin, Fixation, Threaded | | | Product Code: | JDW | | | Substantial Equivalence: | Documentation is provided which demonstrates the SBi<br>Titanium Threaded Pin to be substantially equivalent to<br>other legally marketed devices. | | | Device Description: | The SBi Titanium Threaded Pin consists of a set of<br>titanium threaded pins for internal fixation. Each threaded<br>pin has a machined groove that provides a "break-away"<br>capability. The devices are supplied non-sterile and are<br>available in various sizes diameters and lengths. | | | Intended Use: | The SBi Titanium Threaded Pin is indicated for bone<br>reconstruction, osteotomy, arthrodesis, joint fusion, fracture<br>repair, and fracture fixation of bones appropriate for the<br>size of the device. | | | Material: | The implants are made from Ti-6Al-4V per ISO 5832-3 | | . {2}------------------------------------------------ Image /page/1/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a circular seal with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" around the perimeter. Inside the circle is an abstract image of an eagle or bird-like figure with three stylized lines representing its wings or feathers. AUG - 8 2007 Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 Small Bone Innovations, Inc. % Mr. Robert Hoehn Regulatory Associate Musculoskeletal Clinical Regulatory Advisers, LLC 505 Park Avenue, 14th Floor New York, New York 10022 K071540 Re: Trade/Device Name: SBi Titanium Threaded Pin Regulation Number: 21 CFR 888.3040 Regulation Name: Smooth or threaded metallic bone fixation fastener Regulatory Class: Class II Product Code: JDW Dated: May 25, 2007 Received: June 5, 2007 Dear Mr. Hoehn: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. {3}------------------------------------------------ Page 2 - Mr. Robert Hoehn This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Center for Devices and Radiological Health's (CDRH's) Office of Compliance at (240) 276-0120. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding postmarket surveillance, please contact CDRH's Office of Surveillance and Biometric's (OSB's) Division of Postmarket Surveillance at 240-276-3474. For questions regarding of device adverse events (Medical Device Reporting (MDR)), please contact the Division of Surveillance Systems at (240) 276-3464. You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at toll-free number (800) 638-2041 or (240) 276-3150 or the Internet address http://www.fda.gov/cdrh/industry/support/index.html. Sincerely yours, Barbara Buchur Mark N. Melkerson Director Division of General, Restorative and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {4}------------------------------------------------ 071540 p. '/1 ## Indications for Use 510(k) Number: Device Name: SBi Titanium Threaded Pin Indications For Use: The SBi Titanium Threaded Pin is indicated for bone reconstruction, osteotomy, arthrodesis, joint fusion, fracture repair, and fracture fixation of bones appropriate for the size of the device. Prescription Use V (Part 21 CFR 801 Subpart D) AND/OR Over-The-Counter Use (21 CFR 807 Subpart C) (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) Page 1 of 1 Barbara Buehrn (Division of General, Restorative, and Neurological Devices 510(k) Number K070540
Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...