Embrace™ Dual Cure Composite Materials are multi-purpose, hydrophilic, fluoride-releasing, resin-based materials that contain no Bisphenol A and bond tightly to dentition. Embrace™ Dual Cure Composite Materials are used to permanently cement dental posts, porcelain crowns, inlays, onlays, bridges, porcelain/laminate veneers and periodontal splints, to repair porcelain crowns intra-orally and as a build-up and repair material.
Device Story
Embrace™ Dual Cure Composite Materials are multi-purpose, hydrophilic, fluoride-releasing, resin-based dental materials; Bisphenol A-free. Used by dental professionals for permanent cementation of restorations (posts, crowns, inlays, onlays, bridges, veneers, splints), intra-oral porcelain repair, and tooth build-up. Material bonds to dentition; dual-cure mechanism allows for polymerization. Benefits include high benefit-to-risk ratio and established safety profile for dental restorative materials.
Clinical Evidence
No clinical data provided. Substantial equivalence is based on comparison to legally marketed predicate devices and historical safety data for dental restorative materials cited from NIH Technology Assessment Conference.
Technological Characteristics
Hydrophilic, fluoride-releasing, resin-based composite material. Dual-cure polymerization mechanism. Bisphenol A-free formulation. Classified as tooth shade resin material under 21 CFR 872.3690.
Indications for Use
Indicated for permanent cementation of dental posts, porcelain crowns, inlays, onlays, bridges, porcelain/laminate veneers, and periodontal splints; intra-oral repair of porcelain crowns; and as a dental build-up and repair material. No specific patient population age or gender restrictions provided.
Regulatory Classification
Identification
Tooth shade resin material is a device composed of materials such as bisphenol-A glycidyl methacrylate (Bis-GMA) intended to restore carious lesions or structural defects in teeth.
Predicate Devices
Pulpdent Embrace™ Resin Cement
Pulpdent Embrace™ WetBond Pit and Fissure Sealant
Pulpdent ResiLute Resin Cement
Pulpdent VLC Resin Cement
Pulpdent Embrace™ WetBond Restorative Materials
Apex Dental Materials anchor®
Den-Mat Core Paste XP
Submission Summary (Full Text)
{0}------------------------------------------------
# K07127
## EXHIBIT 2
# SUMMARY OF SAFETY AND EFFECTIVENESS DATAJUN 2 9 2007
Kenneth J. Berk 80 Oakland Street PO Box 780 Watertown, MA 02472 USA
617-926-6666 Telephone: Fax: 617-926-6262 ken@pulpdent.com
#### DEVICE:
Trade Name: PULPDENT EMBRACE™ DUAL CURE COMPOSITE MATERIALS Classification Name: Tooth shade resin material FDA Product Code: 76 EBF. 21 CFR Part 872.3690
#### PREDICATE DEVICES:
Pulpdent Embrace™ Resin Cement Pulpdent Embrace™ WetBond Pit and Fissure Sealant Pulpdent ResiLute Resin Cement Pulpdent VLC Resin Cement Pulpdent Embrace™ WetBond Restorative Materials Apex Dental Materials anchor® Den-Mat Core Paste XP
#### DESCRIPTION AND INTENDED USE:
Embrace™ Dual Cure Composite Materials are multi-purpose, hydrophilic, fluoride-releasing, resin-based materials that contain no Bisphenol A and bond tightly to dentition.
Embrace™ Dual Cure Composite Materials are used to permanently cement dental posts, porcelain crowns, inlays, onlays, bridges, porcelain/laminate veneers and periodontal splints, to repair porcelain crowns intra-orally and as a build-up and repair material.
#### COMPARISON WITH PREDICATE PRODUCTS:
PULPDENT DUAL CURE COMPOSITE MATERIALS are substantially equivalent in design, composition, performance, intended use, safety and effectiveness to the predicate products listed above.
#### SAFETY AND EFFECTIVENESS:
PULPDENT DUAL CURE COMPOSITE MATERIALS are substantially equivalent in design, composition, performance, intended use, safety and effectiveness to the predicate products listed above. The predicate products have been found substantially equivalent under the 510/k) Premarket Notification process as Class II Dental Devices under CFR 872.3690, 872.3275 and 872.3765.
According to the NIH Technology Assessment Conference on Effects and Side-Effects of Dental Restorative Materials: "General usage of these materials over about 20 years indicates a high benefit-torisk ratio...both composites and glass ionomers are relatively trouble-free. There is no evidence of shortterm or long-term risk...There is no suspicion of any problems after virtually billions of procedures in the United States."
{1}------------------------------------------------
Image /page/1/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo features a stylized depiction of an eagle with its wings spread, symbolizing protection and care. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged in a circular pattern around the eagle. The logo is in black and white.
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
# JUN 2 9 2007
Mr. Kenneth J. Berk Director Pulpdent Corporation 80 Oakland Street P.O. Box 780 Watertown, Massachusetts 02472
Re: K071278
Trade/Device Name: Embrace™ Dual Cure Composite Materials Regulation Number: 21 CFR 872.3690 Regulation Name: Tooth Shade Resin Material Regulatory Class: II Product Codes: EBF and EMA Dated: May 02, 2007 Received: May 07, 2007
Dear Mr. Berk:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
{2}------------------------------------------------
# Page 2 -- Mr. Kenneth J. Berk
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at (240) 276-0115. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (240) 276-3150 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html.
Sincerely yours,
Suita y. Michaud.
Chiu S. Lin, PhD Director Division of Anesthesiology, General Hospital, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{3}------------------------------------------------
## INDICATIONS FOR USE
510 (k) Number (if known)
0717 28
Device Name
#### PULPDENT EMBRACE™ DUAL CURE COMPOSITE MATERIALS
#### Indications for Use:
Embrace™ Dual Cure Composite Materials are multi-purpose, hydrophilic, fluoride-releasing, resin-based materials that contain no Bisphenol A and bond tightly to dentition.
Embrace™ Dual Cure Composite Materials are used to permanently cement dental posts, porcelain crowns, inlays, onlays, bridges, porcelain/laminate veneers and periodontal splints, to repair porcelain crowns intra-orally and as a build-up and repair material.
Prescription Use (Part 21 CFR 801 Subpart D)
or
Over-The-Counter Use (21 CFR 807 Subpart C)
Please do not write below this line. Continue on another page if needed.
Concurrence of CDRH, Office of Device Evaluation (ODE)
Susan Runne
540(k) Number
...sion Sign-Off)
Division of Anesthesiology, General Hospital,
..ection Control, Dental Devices
Page 1 of 1
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.