INTEGRITY LOW SPEED DENTAL AIR HANDPIECE AND ATTACHMENT, MODELS: MOTOR INT-E, MOTOR INT-D AND ATTACHMENT INT-SNC

K070155 · Osseo Scientific, LLC · EFB · Jan 25, 2007 · Dental

Device Facts

Record IDK070155
Device NameINTEGRITY LOW SPEED DENTAL AIR HANDPIECE AND ATTACHMENT, MODELS: MOTOR INT-E, MOTOR INT-D AND ATTACHMENT INT-SNC
ApplicantOsseo Scientific, LLC
Product CodeEFB · Dental
Decision DateJan 25, 2007
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 872.4200
Device ClassClass 1
AttributesTherapeutic, 3rd-Party Reviewed

Indications for Use

The INTEGRITY Air Powered Low Speed Handpieces are intended for removing curious material, reducing hard tooth structure, cavity preparation, finishing tooth preparations, restorations and polishing teeth for use by a trained professional in general dentistry.

Device Story

Integrity Low Speed Dental Air Handpiece is a 5-vane air-powered motor system; operates at speeds up to 20,000 RPM. Compatible with standard 2, 3, or 4-hole air connections; accepts ISO E-Type or U-Type attachments. Used in clinical dental settings by trained professionals for restorative procedures, cavity preparation, and tooth polishing. Device functions via pneumatic power; provides mechanical rotation to dental burs or polishing tools. Healthcare providers use the handpiece to manually manipulate tooth structure; output is the physical removal or finishing of dental material. Benefits include efficient tooth preparation and restoration maintenance.

Clinical Evidence

Bench testing only. No clinical data provided. Equivalence established through comparison of design specifications, materials, and performance characteristics against legally marketed predicate devices.

Technological Characteristics

5-vane air motor; max speed 20,000 RPM. Compatible with ISO E-Type/U-Type attachments and standard 2, 3, or 4-hole air connections. Complies with ISO 7785-2 (low speed handpieces), ISO 1797 (shank dimensions), ISO 9168 (hose connectors), and ISO 3964 (coupling dimensions). Sterilizable.

Indications for Use

Indicated for use by trained dental professionals for removal of carious material, reduction of hard tooth structure, cavity preparation, finishing of preparations, restorations, and tooth polishing in general dentistry patients.

Regulatory Classification

Identification

A dental handpiece and accessories is an AC-powered, water-powered, air-powered, or belt-driven, hand-held device that may include a foot controller for regulation of speed and direction of rotation or a contra-angle attachment for difficult to reach areas intended to prepare dental cavities for restorations, such as fillings, and for cleaning teeth.

Predicate Devices

Submission Summary (Full Text)

{0}------------------------------------------------ K070155 ### 510(k) SUMMARY ## OSSEO SCIENTIFIC, LLC INTEGRITY LOW SPEED HANDPIECE & ATTACHMENT 1. Submitter Name, Address, Phone/Fax Registration No. 3005405362 Osseo Scientific, LLC 3138 Veeder Ave. Toms River, NJ 08753 USA Telephone # 201-490-5421 Facsimile # 201-490-5423 2. Contact Person-Owner Michael Feldman Telephone # 732-597-5971 3. Date summary prepared: October-28-2006 4. Device Name: Trade Name: INTEGRITY Low Speed Dental Air Handpiece and Accessories. Model No's INT-E, INT-D, INT-SNC. Common Name: Handpiece Low Speed Dental. Classification Name: Dental Handpiece and Accessories. ( 21CFR 872.4200 ) Product Code: 76 EFB ( "Handpiece, Air-Powered, Dental" ). Device Class: Class I 5. Indications for Use: The INTEGRITY Air Powered Low Speed Handpieces are intended for removing curious material, reducing hard tooth structure, cavity preparation, finishing tooth preparations, restorations and polishing teeth for use by a trained professional in general dentistry. 'JAN 2 5 2007 {1}------------------------------------------------ - 6. Predicate Device Name: For Model INT-E: A-dec/W&H Synea & TreND Low Speed (K944713 & K993526) and Dabi Atlante Low Speed (K926154). For Model INT-SNC: A-dec/W&H Synea & TreND ( K993526), Dabi Atlante (K926155) and MK-dent Straight Handpiece (K051872) For Model INT-D: Promident Low Speed (K781545) 7. Description of Device: The Integrity Low Speed Handpiece is a 5-vane motor, ranging in speed up to 20,000 RPM, and is compatible to all standard 2, 3 or 4 hole fixed air connection. It accepts all brands of ISO E-Type or U-Type attachments. The Motors and Straight Nose Cone are used for general dentistry procedures. - 8. Substantially Equivalence- Safety and Effectiveness: The INTEGRITY Low Speed handpieces share virtually all specifications and design characteristics of the predicate devices and are Identical or similar based on comparisons of formulations and intended uses as shown below. The handpieces are constructed of materials of identical specification as the predicate device. Air Connection, and interface with other dental attachments were Identical. Air Pressure and, speed Results were similar. It is therefore Substantially Equivalent to one or more dental handpieces currently marketed in the USA. The Handpieces conform to applicable ISO standards. The ability to repeatedly adequately sterilize the device is being confirmed by validation protocol, and will be available for inspection before the device is marketed. | > Intended use; | Identical | |------------------------------------------------|-----------| | > Indications for use; | Identical | | > Target population; | Identical | | > Anatomical sites; | Identical | | > Where used (hospital, home, ambulance, etc); | Identical | | > Energy used and/or delivered; | Identical | | > Human factors; | Identical | | > Design; | Similar | | > Performance; | Identical | | > Standards met | Identical | | > Materials | Identical | {2}------------------------------------------------ | > Biocompatibility | | |------------------------------------------------------------------|--| | > Compatibility with the environment and other devices Identical | | | > Sterility | | | > Mechanical safety | | | > Electrical safety | | | > Chemical safety | | | > Thermal safety | | | > Radiation safety | | 8. Conclusion: Based on information in the notification Osseo Scientific, LLC believes that INTEGRITY Air Powered Low Speed Handpieces are substantially equivalent to the claimed predicate, i.e., For Model INT-E: A-dec/W&H Synea & TreND Low Speed (K944713 & K993526) and Dabi Atlante Low Speed (K926154). For Model INT-SNC: A-dec/W&H Synea & TreND ( K993526), Dabi Atlante (K926155) and MK-dent Straight Handpiece (K051872) For Model INT-D: Promident Low Speed (K781545) #### Voluntary Standard Compliance: ISO Standard 7785-2: Low Speed Dental Handpiece. ISO Standard 1797: Shank Dimensions. ISO Standard 9168: Hose Connectors. ISO Standard 3964: Coupling Dimensions {3}------------------------------------------------ Image /page/3/Picture/1 description: The image shows the logo for the U.S. Department of Health and Human Services. The logo features a stylized caduceus symbol, which is a staff with two snakes entwined around it. The symbol is surrounded by the text "DEPARTMENT OF HEALTH AND HUMAN SERVICES, USA" in a circular arrangement. The logo is black and white. Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 JAN 2 5 2007 Osseo Scientific, LLC C/O Mr. Neil E. Devine Responsible Third Party Official Intertek Testing Services NA, Incorporated 2307 East Aurora Road, Unit B7 Twinsburg, Ohio 44087 Re: K070155 Trade/Device Name: Integrity Low Speed Air Dental Handpiece and Attachment Regulation Number: 872.4200 Regulation Name: Dental Handpiece and Accessories Regulatory Class: I Product Code: EFB Dated: January 16, 2007 Received: January 17, 2007 Dear Mr. Devine: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations offecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. {4}------------------------------------------------ #### Page 2 - Mr. Devine Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act): 21 CFR 1000-1050. This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at (240) 276-. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html. Sincerely yours. Sujata Y. Michael D.M.D. Chiu Lin, Ph.D. Director Division of Anesthesiology, General Hospital, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {5}------------------------------------------------ # Indications for Use 510(k) Number (if known): ____________________________________________________________________________________________________________________________________________________ Device Name: Integrity Low Speed Air Dental Handpiece and Attachment. Models: Motor INT-E, Motor INT-D and Attachment INT-SNC Indications for Use: The INTEGRITY Air Powered Low Speed Handpieces are intended for removing carious material, reducing hard tooth structure, savity preparation, finishing tooth preparations, restorations and polishing teeth for use by a trained professional in general dentistry. Prescription Use X (Part 21 CFR 801 Subpart D) Over-The-Counter Use AND/OR (21 CFR 801 Subpart C) (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE OF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) Susan Runns 10) 54 Page 1 of 1
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...