K063679 · Instrumentation Laboratory CO · GKP · Jan 12, 2007 · Hematology
Device Facts
Record ID
K063679
Device Name
ACL TOP
Applicant
Instrumentation Laboratory CO
Product Code
GKP · Hematology
Decision Date
Jan 12, 2007
Decision
SESE
Submission Type
Special
Regulation
21 CFR 864.5400
Device Class
Class 2
Intended Use
The ACL TOP is a bench top, fully automated, random access analyzer designed specifically for in vitro diagnostic clinical use in the hemostasis laboratory for coagulation and/or fibrinolysis testing in the assessment of thrombosis and/or hemostasis. The system provides results for both direct hemostasis measurements and calculated parameters.
Device Story
Instrument performs intrinsic and extrinsic factor assays; modification optimizes assay performance. Input: patient samples; calibration via direct aspiration from vials. Processing: polynomial curve fitting or segmented calibration curves; optimized incubation times, transport air gaps, and probe rinse parameters. Output: assay results for clinical decision-making. Used in clinical laboratory settings by trained personnel.
Clinical Evidence
No clinical data provided. Substantial equivalence is supported by bench testing of the optimized factor assay applications to demonstrate performance consistency with the predicate device.
Technological Characteristics
Benchtop, fully automated, random access coagulation analyzer. Features include automated sample handling, probe-based aspiration, and incubation systems. Software-controlled assay parameters include calibration curve generation (polynomial and segmented fitting), direct dilution, and optimized fluidic/incubation timing. Connectivity and specific material standards are not detailed.
Indications for Use
Indicated for in vitro diagnostic clinical use in hemostasis laboratories for coagulation and/or fibrinolysis testing to assess thrombosis and/or hemostasis.
Regulatory Classification
Identification
A coagulation instrument is an automated or semiautomated device used to determine the onset of clot formation for in vitro coagulation studies.
Special Controls
*Classification.* Class II (special controls). A fibrometer or coagulation timer intended for use with a coagulation instrument is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 864.9.
Related Devices
K073377 — ACL TOP (WITH SYSTEM SOFTWARE V3.0.0) · Instrumentation Laboratory CO · May 4, 2008
K033414 — ACL TOP MODEL, TOP · Instrumentation Laboratory CO · Jan 12, 2004
K160276 — ACL TOP (ACL TOP 700, ACL TOP 700 CTS, ACL TOP 700 LAS, ACL TOP 500 CTS, ACL TOP 300 CTS) · Instrumentation Laboratory CO · Mar 3, 2016
Submission Summary (Full Text)
{0}------------------------------------------------
510(k) Summary
K063679
JAN 1 2 2007
## Submitted by:
Instrumentation Laboratory Company 113 Hartwell Avenue Lexington, MA 02421
### Contact Person:
Carol Marble, Regulatory Affairs Director Phone No .: 781-861-4467 781-861-4207 Fax No .:
#### Prepared:
December 8, 2006
#### Device Name:
ACL TOP
## Regulatory Information:
| 81GKP | Instrument, Coagulation, Automated | |
|----------|------------------------------------|----------|
| 864.5400 | Coagulation Instrument | Class II |
### Predicate Device:
K033414 ACL TOP
## Device Description:
The ACL TOP is a bench top, fully automated, random access analyzer designed specifically for in vitro diagnostic clinical use in the hemostasis laboratory for coagulation and/or fibrinolysis testing in the assessment of thrombosis and/or hemostasis. The system provides results for both direct hemostasis measurements and calculated parameters.
#### Reason for Submission:
The ACL TOP system software and test parameters are being modified to optimize the performance of the intrinsic and extrinsic factor assay applications on the instrument.
Major software/test parameter modifications to the factor assays include:
- 1. The calibration levels are now prepared by aspirating the calibrator directly from the calibrator vial (direct dilution instead of serial dilution).
- 2. The number of calibration points is being increased from 5 to either 7 or 8, dependent on the individual factor.
- 3. New mathematical tools are being implemented for generating the calibration curve, e.g. polynomial curve fitting capability as well as the capability for using segmented calibration curve (two different calibration curves for the lower and upper ends).
- 4. The robustness of the assays is increased by optimizing incubation time, transport air gap and probe rinse parameter modifications.
# Statement of Technological Characteristics of the Device Compared to Predicate Device:
The performance of the optimized factor assay applications on the ACL TOP (K033414) is substantially equivalent to the performance of the current legally marketed factor assay applications on the ACL TOP (K033414).
- There are no changes to the formulation of the factor assays, and no changes to the NOTE: intended use/indications for use or labeled performance claims of either the ACL TOP or the factor assays with this submission.
{1}------------------------------------------------
## DEPARTMENT OF HEALTH & HUMAN SERVICES
Image /page/1/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo features a stylized eagle with its wings spread, symbolizing protection and care. The eagle is positioned within a circular border that contains the text "DEPARTMENT OF HEALTH & HUMAN SERVICES . USA" in a sans-serif font. The overall design is simple and professional, reflecting the department's role in public health and welfare.
Public Health Service
Food and Drug Administration 2098 Gaither Road Rockville MD 20850
Ms. Carol Marble Regulatory Affairs Director Instrumentation Laboratory Co. 113 Hartwell Avenue Lexington, MA 02421
k063679 Re: Trade/Device Name: ACL TOP Regulation Number: 21 CFR § 864.5400 Regulation Name: Coagulation Instrument Regulatory Class: II Product Code: GKP Dated: January 4, 2007 Received: January 5, 2007
JAN 1 2 2007
Dear Ms. Marble:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in Title 21, Code of Federal Regulations (CFR), Parts 800 to 895. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Parts 801 and 809); and good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820). This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
{2}------------------------------------------------
Page 2 –
If you desire specific information about the application of labeling requirements to your device, or questions on the promotion and advertising of your device, please contact the Office of In Vitro Diagnostic Device Evaluation and Safety at (240) 276-0484. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html
Sincerely yours,
Robert L. Becker Jr.
Robert L. Becker, Jr., MD, PH.D Director Division of Immunology and Hematology Office of In Vitro Diagnostic Device Evaluation and Safety Center for Devices and Radiological Health
Enclosure
{3}------------------------------------------------
# Indications for Use Statement
510(k) Number (if known): K063679
Device Name: ACL TOP
## Indications for Use:
The ACL TOP is a bench top, fully automated, random access analyzer designed specifically for in vitro diagnostic clinical use in the hemostasis laboratory for coagulation and/or fibrinolysis testing in the assessment of thrombosis and/or hemostasis.
The system provides results for both direct hemostasis measurements and calculated parameters.
Prescription Use (Part 21 CFR 801 Subpart D)
AND/OR
Over-The-Counter Use (21 CFR 801 Subpart C)
(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of In Vitro Diagnostic Devices (OIVD)
Josephine Bautista
Division Sign-Off
Office of In Vitro Diagnostic Device Evaluation and Safety
Section 2
Special 510(k): ACL TOP Factor Assay Optimization
Page 1 of 1
Panel 1
/
Sort by
Ready
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.