← Product Code [LLZ](/productcode/LLZ) · K062757

# XERON PACS (K062757)

_Xeron Healthcare Corp. · LLZ · Nov 7, 2006 · Radiology · SESE_

**Canonical URL:** https://fda.innolitics.com/device/K062757

## Device Facts

- **Applicant:** Xeron Healthcare Corp.
- **Product Code:** [LLZ](/productcode/LLZ.md)
- **Decision Date:** Nov 7, 2006
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 892.2050
- **Device Class:** Class 2
- **Review Panel:** Radiology
- **Attributes:** Software as a Medical Device

## Indications for Use

The Xeron PACS is a medical imaging software application intended to display, edit, review, store, print and distribute images acquired from imaging devices such as Computed Tomography (CT), Magnetic Resonance (MR), Computed Radiography (CR), Ultrasound (US), Nuclear Medicine (NM), and other devices.

## Device Story

Xeron PACS is a software-based image management system for medical environments. It acquires, displays, edits, reviews, stores, prints, and distributes standard DICOM medical images. Inputs include image data from various modalities (CT, MR, CR, US, NM). The system consists of five software components: XP WebStation, XP RadStation, XP Site Administrator, XP Data Router, and XP Server Manager. It supports DICOM network structures for image acquisition and distributes images to desktop computers, intranet/internet-connected systems, hardcopy devices, and Hospital Information Systems (HIS). Used by authorized clinical personnel to facilitate image review and clinical decision-making.

## Clinical Evidence

Bench testing only. The device was demonstrated to perform as intended through internal verification and validation of software functionality.

## Technological Characteristics

Software-based PACS; DICOM-compliant; supports network connectivity via intranet/internet; modular architecture consisting of five software components (WebStation, RadStation, Site Administrator, Data Router, Server Manager).

## Regulatory Identification

A medical image management and processing system is a device that provides one or more capabilities relating to the review and digital processing of medical images for the purposes of interpretation by a trained practitioner of disease detection, diagnosis, or patient management. The software components may provide advanced or complex image processing functions for image manipulation, enhancement, or quantification that are intended for use in the interpretation and analysis of medical images. Advanced image manipulation functions may include image segmentation, multimodality image registration, or 3D visualization. Complex quantitative functions may include semi-automated measurements or time-series measurements.

## Special Controls

*Classification.* Class II (special controls; voluntary standards—Digital Imaging and Communications in Medicine (DICOM) Std., Joint Photographic Experts Group (JPEG) Std., Society of Motion Picture and Television Engineers (SMPTE) Test Pattern).

## Predicate Devices

- GE Centricity PACS ([K043415](/device/K043415.md))

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

K062757

510(k) Premarket Notification

Page 1 of 2

## 510(k) SUMMARY

NOV - 7 2006

## General Information

| Submitted by:   | XERON Healthcare Corp.<br>A-206 Hi-Tech Venture Center, 647-26<br>Deungchon-Dong, Gangseo-Gu<br>Seoul, Korea<br><br>Phone: +82 2 3663 8424<br>Fax: +82 2 3663 8426                            |
|-----------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Contact Person: | Mr. Douglas Kim<br>A-206 Hi-Tech Venture Center, 647-26<br>Deungchon-Dong, Gangseo-Gu<br>Seoul, Korea<br><br>Phone: +82 2 3663 8424<br>Fax: +82 2 3663 8426<br>Email: douglas_kim@xeron.co.kr |
| Date Prepared:  | September 11, 2006                                                                                                                                                                            |

## Device Name

| Trade Name:          | Xeron PACS                                  |
|----------------------|---------------------------------------------|
| Common Name:         | Picture Archiving and Communications System |
| Classification Name: | System, Image Processing, Radiological,     |
|                      | 21 CFR 892.2050                             |

## Predicate Device

| Manufacturer                                   | Product Name       | 510(k) No. |
|------------------------------------------------|--------------------|------------|
| GE Medical Systems<br>Information Technologies | GE Centricity PACS | K043415    |

{1}------------------------------------------------

#### Device Description

Xeron PACS is an image management system that allows authorized personnel to acquire, display, edit, review, store, print, and distribute standard Digital Imaging and Communications in Medicine (DICOM) medical images within a Picture Archiving and Communication System (PACS) environment. The Xeron PACS system consists of five software components:

- · XP WebStation
- · XP RadStation
- · XP Site Administrator
- · XP Data Router
- · XP Server Manager

Xeron PACS supports DICOM network structures which allow for efficient medical image acquisition from any medical modality, including CT, MR, CR, and others. Distribution of images is provided to desktop computer systems, computer systems connected by intranet or internet, hardcopy devices, and Hospital Information Systems (HIS).

### Intended Use

The Xeron PACS is a medical imaging software application intended to display, edit, review, store, print and distribute images acquired from imaging devices such as Computed Tomography (CT), Magnetic Resonance (MR), Computed Radiography (CR), Ultrasound (US), Nuclear Medicine (NM), and other devices.

#### Technological Comparison

Xeron PACS and GE Centricity PACS are software applications that have similar indications for use and overall function and perform in a similar manner with respect to image processing systems (i.e. PACS).

### Testing

Xeron PACS has been demonstrated to perform as intended.

#### Conclusions

Xeron PACS is substantially equivalent to legally marketed Image Processing Systems (i.e. PACS).

{2}------------------------------------------------

Image /page/2/Picture/0 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a circular seal with the words "DEPARTMENT OF HEALTH & HUMAN SERVICES USA" arranged around the perimeter. Inside the circle is a stylized symbol resembling three parallel lines that curve and merge together, forming a shape that could be interpreted as a stylized human figure or a flame.

Food and Drug Administration 9200 Corporate Blvd. Rockville MD 20850

XERON Healthcare Corp. % Mrs. Melissa Mahall Director, Regulatory Affairs Bio-Reg Associates, Inc. 6304 Belmont Circle, Bldg 2 MOUNT AIRY MD 21771

NOV - 7 2006

Re: K062757

Trade/Device Name: Xeron PACS Regulation Number: 21 CFR 892.2050 Regulation Name: Picture archiving and communications system Regulatory Class: II Product Code: LLZ Dated: September 11, 2006 Received: September 20, 2006

Dear Mrs. Mahall:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.

If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

Image /page/2/Picture/10 description: The image is a circular logo with the text "1906-2006" at the top. Below the text is the acronym "FDA" in large, bold letters. Underneath the acronym is the word "Centennial" in a cursive font. There are three stars below the word "Centennial". The logo is surrounded by a circular border.

Protecting and Promoting Public Health

{3}------------------------------------------------

#### Page 2 -

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.

This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at one of the following numbers, based on the regulation number at the top of this letter:

| 21 CFR 876.xxx | (Gastroenterology/Renal/Urology) | 240-276-0115 |
|----------------|----------------------------------|--------------|
| 21 CFR 884.xxx | (Obstetrics/Gynecology)          | 240-276-0115 |
| 21 CFR 894.xxx | (Radiology)                      | 240-276-0120 |
| Other          |                                  | 240-276-0100 |

Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (240) 276-3150

or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html.

Sincerely yours,

Nancy C. Hogdon

Nancy C. Brogdon Director, Division of Reproductive, Abdominal, and Radiological Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{4}------------------------------------------------

# INDICATIONS FOR USE

510(k) Number (if known):

K1062757

Device Name: Xeron PACS

Sponsor Name: XERON Healthcare Corp.

Indications for Use:

The Xeron PACS is a medical imaging software application intended to display, edit, review, store, print and distribute images acquired from imaging devices such as Computed Tomography (CT), Magnetic Resonance (MR), Computed Radiography (CR), Ultrasound (US), Nuclear Medicine (NM), and other devices.

Prescription Use XI (21 CFR 801 Subpart D)

Or

Over-The-Counter Use | | (21 CFR 807 Subpart C)

Do Not Write Below This Line – Continue on Another Page if Needed

Concurrence of CDRH, Office of Device Evaluation (ODE)

510(k) Number

Nancy Brogdon

(Division Sign-Off)
Division of Reproductive, Abdominal,
and Radiological Devices

---

**Source:** [https://fda.innolitics.com/device/K062757](https://fda.innolitics.com/device/K062757)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
