DISPOSABLE POSTERIOR LUMBAR STABILIZATION PROCEDURE KIT, MODELS 9045-01 AND 9045-02; COMPRESSION TOOL, MODEL 6113-00

K062391 · Triage Medical, Inc. · MRW · Sep 14, 2006 · OR

Device Facts

Record IDK062391
Device NameDISPOSABLE POSTERIOR LUMBAR STABILIZATION PROCEDURE KIT, MODELS 9045-01 AND 9045-02; COMPRESSION TOOL, MODEL 6113-00
ApplicantTriage Medical, Inc.
Product CodeMRW · OR
Decision DateSep 14, 2006
DecisionSESE
Submission TypeTraditional
Device ClassClass U
AttributesTherapeutic

Indications for Use

The intended use of the 4.5mm Facet Compression Device contained in the Disposable Posterior Lumbar Stabilization Disposable Kit is to stabilize the spine as an aid to fusion through bilateral immobilization of the facet joints, with or without bone graft at single or multiple levels from L1 to S1. The intended use of the associated manual surgical instruments is to aid in the implantation of the 4.5mm Facet Compression Device.

Device Story

The Disposable Posterior Lumbar Stabilization Procedure Kit provides a 4.5mm double-helix facet screw with a compression-locking collar and self-retaining washer, alongside manual surgical instruments. The device is used by surgeons in an operating room setting to stabilize the spine as an aid to fusion. The screw is inserted posteriorly through the superior side of the facet, across the facet joint, and into the pedicle to achieve bilateral immobilization. The kit is provided sterile via gamma radiation, while a reusable compression tool is provided non-sterile for on-site steam autoclave sterilization. The device provides mechanical stabilization to the spine, potentially benefiting patients by facilitating fusion in cases of instability or degenerative conditions.

Clinical Evidence

Bench testing only. Performance test results indicate the device is safe and satisfies functional and performance requirements for its intended use.

Technological Characteristics

Titanium alloy (ASTM F-136). Double-helix screw design with compression-locking collar and self-retaining washer. 4.5mm diameter; 30-40mm length range. Manual surgical instruments included. Sterilization: Gamma radiation (kit); moist heat/steam autoclave (reusable tool).

Indications for Use

Indicated for patients with spondylolisthesis, spondylolysis, degenerative disc disease (DDD) (back pain of discogenic origin confirmed by radiography), facet degeneration with instability and fracture, pseudoarthrosis, or failed previous fusion. Used for bilateral facet fixation at single or multiple levels from L1 to S1.

Predicate Devices

Submission Summary (Full Text)

{0}------------------------------------------------ K06239l # 510(k) SUMMARY OF SAFETY AND EFFECTIVENESS #### SUBMITTER INFORMATION | A. | Company Name: | Triage Medical, Inc | SEP 1 4 2006 | |----|--------------------|--------------------------------------------------------------------|--------------| | B. | Company Address: | 13700 Alton Parkway<br>Suite 160<br>Irvine, CA 92618 | | | C. | Company Phone: | (949) 472-0006 | | | D. | Company Facsimile: | (949) 472-0016 | | | E. | Contact Person: | Gayle Hirota<br>Manager, Quality Assurance & Regulatory<br>Affairs | | #### DEVICE IDENTIFICATION | A. | Trade Name: | Disposable Posterior Lumbar Stabilization<br>Procedure Kit and Re-usable Compression Tool | |----|----------------------|-------------------------------------------------------------------------------------------| | B. | Catalog Number: | 9045-01, 9045-02 and 6113-00 | | C. | Common Name: | Facet Screw and associated manual surgical<br>instruments | | D. | Classification Name: | Unclassified, various manual surgical<br>instruments | | E. | Product Code: | MRW, HXI, HTW, HXX, HWB, HWX, MJG, HWN | | F. | Device Panel: | Orthopedic and General and Plastic Surgery | | G. | Device Class: | Class II | # IDENTIFICATION OF MODIFIED DEVICE The Disposable Posterior Lumbar Stabilization Procedure Kit is similar in design and intended use to the Triage Medical BONE-LOK® 4.5mm Facet Screw and BONE-LOK® FS Instrument Kit cleared under 510(k) K043351. ## DEVICE DESCRIPTION The 4.5mm Facet Compression Device(s) contained in the Disposable Posterior Lumbar Stabilization Procedure Kit is a double-helix screw with a compression-locking collar and self-retaining washer. It is available as 4.5mm diameter device and is obtainable in a 30-40mm length range. Disposable surgical instruments for use in implanting the device are {1}------------------------------------------------ also included in the kit. The kit is provided "STERILE"; sterilization is by gamma radiation. The re-usable Compression Tool is provided separately in a "NONSTERILE" condition; sterilization is by moist heat (steam autoclaye) and is performed on-site. #### INDICTIONS FOR USE The 4.5mm Facet Compression Device with Washer, which is included in the Disposable Posterior Lumbar Stabilization Procedure Kit, is indicated for spondylolisthesis. spondylolysis, degenerative disc disease (DDD) as defined by back pain of discogenic origin as confirmed by radiographic studies, degeneration of the facets with instability and fracture, pseudoarthrosis or failed previous fusion. ## INTENDED USE The intended use of the 4.5mm Facet Compression Device contained in the Disposable Posterior Lumbar Stabilization Disposable Kit is to stabilize the spine as an aid to fusion through bilateral immobilization of the facet joints, with or without bone graft at single or multiple levels from L1 to S1. The intended use of the associated manual surgical instruments is to aid in the implantation of the 4.5mm Facet Compression Device. # TECHNOLOGICAL CHARACTERISTICS The 4.5mm Facet Compression Device contained in the Disposable Posterior Lumbar Stabilization Procedure Kit is identical to the previously cleared BONE-LOK® 4.5mm Facet Screw. The manual surgical instruments are substantially equivalent to the instruments cleared as the BONE-LOK® FS Instrument Kit. ## BIOCOMPATIBILITY AND PERFORMANCE DATA The 4.5mm Facet Compression Device is made of a titanium alloy, which meets the requirements of ASTM F-136. The materials for the devices as well as the instruments are identical to materials used in a myriad of legally marketed orthopedic spinal fixation devices and instruments. Performance test results indicate that the device is safe and satisfies functional and performance requirements when used as indicated. The associated instruments have also met functional and performance requirements. ## CONCLUSIONS DRAWN FROM STUDIES Test results demonstrate that the devices contained in the Disposable Posterior Lumbar Stabilization Procedure Kit is substantially equivalent to the predicate devices and are capable of safely and effectively performing the stated intended use. {2}------------------------------------------------ Image /page/2/Picture/1 description: The image shows the logo for the U.S. Department of Health and Human Services. The logo features the department's name in a circular arrangement around a symbol. The symbol consists of four stylized human figures in profile, arranged in a row and facing to the right. Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 SEP 1 4 2006 Triage Medical, Inc. % Ms. Gayle Hirota Manager, Quality Assurance and Regulatory Affairs 13700 Alton Parkway, Suite 160 Irvine. California 92618 Re: K062391 Trade/Device Name: Disposable Posterior Lumbar Stabilization (PLS) Procedure Kit Regulation Name: facet screw spinal device system Regulatory Class: Unclassified Product Code: MR W Dated: August 14, 2006 Received: August 16, 2006 Dear Ms. Hirota: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part \$07): iabeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. {3}------------------------------------------------ Page 2 – Ms. Gayle Hirota This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at (240) 276-0120. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (240) 276-3150 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html. Sincerely vours. barbare Buchin Mark N. Melkerson Director Division of General, Restorative and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {4}------------------------------------------------ # Indications for Use 510(k) Number (if known): Device Name: Indications For Use: K062391 Disposable Posterior Lumbar Stabilization (PLS) Procedure Kit The 4.5mm Facet Compression Device, which is included in the Disposable Posterior Lumbar Stabilization Procedure Kit, is indicated for spondylolisthesis, spondylolysis, degenerative disc disease (DDD) as defined by back pain of discogenic origin as confirmed by radiographic studies, degeneration of the facets with instability and fracture, pseudoarthrosis or failed previous fusion. The intended use of the 4.5mm Facet Compression Device is to stabilize the spine as an aid to fusion through bilateral immobilization of the facet joints. The screws are inserted posteriorly through the superior side of the facet, across the facet joint and into the pedicle. The 4.5mm Facet Compression Device is indicated for bilateral facet fixation. with or without bone graft, at single or multiple levels from L1 to S1. The intended use of the associated manual surgical instruments is to aid in the implantation of the 4.5mm Facet Compression Device. Prescription Use × (Part 21 CFR 801 Subpart D) AND/OR Over-The-Counter Use (21 CFR 807 Subpart C) (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) Karlae Brickner/fs MKM (Division Sign Off) Division of General. Restorative. and Neurological Devices **510(k) Number** K062391 Page 1 of 1
Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...