← Product Code [DQY](/productcode/DQY) · K062084

# 7F ACUMEN CORONARY SINUS VISUALIZATION SYSTEM, MODEL CSVS-7-67 (K062084)

_Acumen Medical, Inc. · DQY · Aug 18, 2006 · Cardiovascular · SESE_

**Canonical URL:** https://fda.innolitics.com/device/K062084

## Device Facts

- **Applicant:** Acumen Medical, Inc.
- **Product Code:** [DQY](/productcode/DQY.md)
- **Decision Date:** Aug 18, 2006
- **Decision:** SESE
- **Submission Type:** Special
- **Regulation:** 21 CFR 870.1250
- **Device Class:** Class 2
- **Review Panel:** Cardiovascular

## Indications for Use

The 7F Acumen Coronary Sinus Visualization System is intended to aid in the visualization of the coronary sinus, provide temporary occlusion during a venogram, and to provide a pathway for delivery of transvenous devices to the coronary sinus and coronary vasculature of the heart.

## Device Story

7F Acumen Coronary Sinus Visualization System (CSVS) is a single-use percutaneous catheter; used to visualize coronary sinus, provide temporary occlusion during venogram, and serve as delivery pathway for transvenous devices to coronary sinus and coronary vasculature. Operated by clinicians in clinical settings. Device facilitates diagnostic and interventional procedures by providing access and visualization support.

## Clinical Evidence

Bench testing only; all components and subassemblies met required specifications.

## Technological Characteristics

Single-use percutaneous catheter; 7F size. Materials are identical to those used in the predicate device and previously cleared products.

## Regulatory Identification

A percutaneous catheter is a device that is introduced into a vein or artery through the skin using a dilator and a sheath (introducer) or guide wire.

## Predicate Devices

- Acumen Coronary Sinus Visualization System ([K042381](/device/K042381.md))

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

K062084
p. 1 of 2

Acumen Medical, Inc.

# AUG 1 8 2006

#### 510(k) Summary 5.

General Information

Date Compiled Classification Trade Name

Submitter

July 18, 2006

Class II

7F Acumen Coronary Sinus Visualization System

Acumen Medical, Inc. 275 Santa Ana Court Sunnyvale, CA 94085

Tel: 408-530-1810 Fax: 408-530-1811

Contact

Marybeth Gamber Director, Regulatory Affairs

## Intended Use

The 7F Acumen Coronary Sinus Visualization System is intended to aid in the visualization of the coronary sinus, provide temporary occlusion during a venogram, and to provide a pathway for delivery of transvenous devices to the coronary sinus and coronary vasculature of the heart.

Predicate Devices

Acumen Coronary Sinus Visualization System K042381 Manufactured by Acumen Medical, Inc.

#### Device Description

The 7F Acumen Coronary Sinus Visualization System (CSVS) is a single-use percutaneous catheter intended to aid in the visualization of the coronary sinus, provide temporary occlusion during a venogram, and to provide a pathway for delivery of transvenous devices to the coronary sinus and coronary vasculature of the heart.

#### Materials

All materials used in the manufacture of the 7F Acumen Coronary Sinus Visualization System are suitable for this use, are identical to the those used in the predicate device, and have been used in numerous previously cleared products

#### Testing

Appropriate testing has been performed and all components, subassemblies, and/or full devices met the required specifications for the completed tests.

#### Summary of Substantial Equivalence

Acumen Medical, Inc. believes the 7F Acumen Coronary Sinus Visualization System is substantially equivalem to the predicate product. The imended use, method of operation,

{1}------------------------------------------------

:

1

.

### Acumen Medical, Inc.

:

.

:

:

and the same of the same of the states of the states of the states

methods of construction and materials used, are either identical or substantially equivalent to existing legally marketed predicate product.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

.

:

Confidential

·

:

{2}------------------------------------------------

Image /page/2/Picture/2 description: The image shows the logo for the U.S. Department of Health and Human Services. The logo features a stylized caduceus, which is a symbol often associated with medicine and healthcare. The caduceus is positioned to the right of the circular text that reads "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA". The logo is simple and monochromatic.

#### Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850

## AUG 1 8 2006

Acumen Medical, Inc. c/o Marybeth Gamber Director, Regulatory Affairs 275 Santa Ana Court Sunnyvale, CA 94085

Re: K062084

Trade Name: 7F Acumen Coronary Sinus Visualization System, Model (CSVS) Regulation Number: 21 CFR §870.1250 Regulation Name: Percutaneous Catheter Regulatory Class: Class II Product Code: DQY Dated: August 9, 2006 Received: July 21, 2006

Dear Ms. Gamber:

We have reviewed your Section 510(k) premarket notification of intent to market the device we nave reviewed four becamed the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate for use surver to May 28, 1976, the enactment date of the Medical Device Amendments, or to conimer to province of the ) 2011-07-12 in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The I va may, atteres, and include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

{3}------------------------------------------------

Page 2 – Ms. Marybeth Gamber

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at (240) 276-0120. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (240) 276-3150 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html.

Sincerely yours.

Q.B.M.

FOR Bram D. Zuckerman, M.D. Director Division of Cardiovascular Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{4}------------------------------------------------

Acumen Medical, Inc.

#### Indications for Use Statement 4. ﭗ ﮨﺎ

:

| 510(k) Number (if known): | This application                                                                                                                                                                                                                                                                                      |
|---------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Device Name:              | 7F Acumen Coronary Sinus Visualization System                                                                                                                                                                                                                                                         |
| Indications for Use:      | The 7F Acumen Coronary Sinus Visualization System is<br>intended to aid in the visualization of the coronary sinus,<br>provide temporary occlusion during a venogram, and to<br>provide a pathway for delivery of transvenous devices to the<br>coronary sinus and coronary vasculature of the heart. |

Prescription Use __X (Per 21 CFR 801 Subpari D) AND/OR

Over-The-Counter Use (Per 21 CFR 801 Subpari C)

# PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)

Concurrence of CDRH, Office of Device Evaluation (ODE)

Q.S.M.

(Division Sign-Off) Division of Cardiovascular Devices 510(k) Number -Ko 62084

---

**Source:** [https://fda.innolitics.com/device/K062084](https://fda.innolitics.com/device/K062084)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
