SMARTINFUSER PAINPUMP, MODEL P49220 W/CATHETER SET; P49224N W/O CATHETER SET

K061409 · Precise Medical Products, Ltd. · MEB · Jun 16, 2006 · General Hospital

Device Facts

Record IDK061409
Device NameSMARTINFUSER PAINPUMP, MODEL P49220 W/CATHETER SET; P49224N W/O CATHETER SET
ApplicantPrecise Medical Products, Ltd.
Product CodeMEB · General Hospital
Decision DateJun 16, 2006
DecisionSESE
Submission TypeSpecial
Regulation21 CFR 880.5725
Device ClassClass 2
AttributesTherapeutic

Indications for Use

The SmartInfuser PainPump™ is intended to provide continuous delivery of a local anesthetic through a catheter inserted directly into the surgical site for postoperative pain management.

Device Story

Disposable pain management system; provides continuous delivery of local anesthetic to surgical sites. Components include compression unit (pump), infusion bag, flow regulator, check valve, multi-bolus set, and optional catheter. Used in clinical settings for postoperative pain management. Operated by healthcare professionals. System delivers medication through catheter inserted directly into surgical site; flow regulated by integrated components. Benefits patient by providing continuous, localized pain relief post-surgery.

Clinical Evidence

No clinical data provided; substantial equivalence based on design and performance characteristics.

Technological Characteristics

Disposable infusion pump system. Components: compression unit, 500ml infusion bag, flow regulator, check valve, multi-bolus set, luer lock syringe, and optional catheter. Mechanical flow regulation. Non-electronic.

Indications for Use

Indicated for postoperative pain management via continuous delivery of local anesthetic to surgical sites in patients requiring such therapy.

Regulatory Classification

Identification

An infusion pump is a device used in a health care facility to pump fluids into a patient in a controlled manner. The device may use a piston pump, a roller pump, or a peristaltic pump and may be powered electrically or mechanically. The device may also operate using a constant force to propel the fluid through a narrow tube which determines the flow rate. The device may include means to detect a fault condition, such as air in, or blockage of, the infusion line and to activate an alarm.

Predicate Devices

Submission Summary (Full Text)

{0}------------------------------------------------ KOBI409 ( JUN 16 2006 Image /page/0/Picture/2 description: The image shows a logo for "PRECISE MEDICAL PRODUCTS LTD." The logo consists of the letters "PMP" in a bold, sans-serif font, with the letters slightly overlapping each other. The words "PRECISE MEDICAL PRODUCTS LTD." are written in a smaller font below the letters "PMP". The logo is in black and white and has a slightly angled perspective. ## 510(k) Summary: SmartInfuser PainPump™ Company Name: Precise Medical Products Ltd. ## Contact Person: Ofer Shay Managing Director Phone: +972-4-980-9193 +972-4-980-8356 Fax: E-mail: ofers@pmp-medical.com ### Authorized US Agent: Mark Dollinger - President Trendlines America 2940 West, 123rd Terrace Leawood, Kansas 66200 Phone: (913) 317-8788 Fax: (913) 317-8788 E-mail: mark@trlines.com Date prepared: May 15, 2006 Trade Name: SmartInfuser PainPump™ Classification name: Pump, infusion Common/usual name: Disposable Pain Management System Product Code: MEB Regulation No.: 880.5725 {1}------------------------------------------------ 10061409 2 of 2 Image /page/1/Picture/1 description: The image shows a logo for "PMP Precise Medical Products LTD." The logo consists of the letters "PMP" stacked on top of each other in a bold, sans-serif font. The words "PRECISE MEDICAL PRODUCTS LTD." are written in a smaller font below the letters "PMP". The logo is in black and white and has a slightly angled perspective. Class: II Panel identification: General Hospital Panel #### Predicate Device: SmartInfuser PainPump™, Precise Medical Products Ltd, Shlomi, Israel, cleared under 510(k) no. K042122. #### Description of the device: The device comprises of the following parts: - SmartCatheter (optional) - - SmartInfuser set with SmartReg flow regulator, T Check Valve and Multi -Bolus (regulating set) - Compression unit (pump) - - 500 ml infusion bag (empty) - - Peel-off introducer(optional) - - Wound Dressing (Medical adhesive bandage) - - 50/60cc luer lock syringe - - -Medication label - Pump label ﺳﺘ - Instructions for use ﻪ - Carrying pouch ﮩ #### Indications for Use: The modified SmartInfuser PainPump is intended to provide continuous delivery of a local anesthetic through a catheter inserted directly into the surgical site for postoperative pain management. #### Substantial Equivalence: The modified SmartInfuser PainPump™ has the same intended use as the original SmartInfuser PainPump™, cleared under 510(k) no. K042122 and has equivalent performance characteristics. It is therefore substantially equivalent to that device. #### Conclusion: The evaluation of the modified SmartInfuser PainPump™ does not raise any additional concerns regarding safety and effectivity and may therefore be considered substantially equivalent to the predicate device. 11-3 {2}------------------------------------------------ Image /page/2/Picture/1 description: The image shows the logo for the U.S. Department of Health and Human Services. The logo is circular and contains the words "DEPARTMENT OF HEALTH AND HUMAN SERVICES, USA" around the perimeter. In the center of the circle is a stylized image of an eagle with its wings spread. Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 JUN 16 2006 Mr. Ofer Shay Managing Director Precise Medical Products, Limited Dora Street (Industrial Zone) Shlomi 22832 ISRAEL Re: K061409 Trade/Device Name: SmartInfuser PainPump™, Disposable Pain Management System Regulation Number: 21 CFR 880.5725 Regulation Name: Infusion Pump Regulatory Class: II Product Code: MEB Dated: May 15, 2006 Received: May 22, 2006 Dear Mr. Shay: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice. labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. {3}------------------------------------------------ Page 2 - Mr. Shay Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal squarences. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing prectice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at (240) 276-0115. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (240) 276-3150 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html. Sincerely yours, Chiu Lin, Ph.D. Director Division of Anesthesiology, General Hospital, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {4}------------------------------------------------ K041409 1 of 1 # Indications for Use 510(k) Number (if known): Device Name: SmartInfuser PainPump™, Disposable Pain Management System The SmartInfuser PainPump™ is intended to provide continuous delivery of a local I he United through a catheter inserted directly into the surgical site for postoperative pain management. Prescription Use V (Part 21 CFR 801 Subpart D) AND/OR Over-The-Counter Use (21 CFR 807 Subpart C) (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) Anthony D. newton on of Anesthesiology, General Hospital. con Control, Denta Page 1 of _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ) Number: 12-2
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...