ENDIUS MINIT POSTERIOR CERVICAL AND UPPER THORACIC FIXATION SYSTEM

K060683 · Endius, Inc. · KWP · Apr 18, 2006 · Orthopedic

Device Facts

Record IDK060683
Device NameENDIUS MINIT POSTERIOR CERVICAL AND UPPER THORACIC FIXATION SYSTEM
ApplicantEndius, Inc.
Product CodeKWP · Orthopedic
Decision DateApr 18, 2006
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 888.3050
Device ClassClass 2
AttributesTherapeutic

Indications for Use

When intended to promote fusion of the cervical spine and the thoracic spine, (C1-T3), the Endius Minit Posterior Cervical and Upper Thoracic Fixation System is indicated for the following: DDD (neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, spinal stenosis, fracture, dislocation, failed previous fusion and/or tumors. Hooks and Rods The hooks and rods are also intended to provide stabilization to promote fusion following reduction of fracture/dislocation or trauma in the cervical/upper thoracic (C1-T3) spine. Screws/Connectors The use of screws is limited to placement in the T1-T3 in treating thoracic conditions only. Screws are not intended to be placed in the cervical spine.

Device Story

Posterior spinal fixation system; components include rods, hooks, screws, and connectors. Fabricated from medical-grade titanium/titanium alloy. Used by surgeons in clinical settings to provide stabilization and promote fusion in the cervical and upper thoracic spine (C1-T3). Components are rigidly locked in various configurations to address degenerative disc disease, fractures, dislocations, and tumors. Screws are restricted to thoracic (T1-T3) application. System provides mechanical support to the spine to facilitate bone fusion.

Clinical Evidence

Bench testing only.

Technological Characteristics

Materials: Medical grade titanium or titanium alloy (ASTM F136). Components: Rods, hooks, screws, multi-axial screws, connectors. Configuration: Rigid locking mechanism. Energy source: None (mechanical). Sterilization: Not specified.

Indications for Use

Indicated for patients requiring cervical/thoracic (C1-T3) spinal fusion due to DDD, spondylolisthesis, spinal stenosis, fracture, dislocation, failed fusion, or tumors. Hooks/rods indicated for stabilization following trauma/fracture reduction. Screws limited to T1-T3 thoracic use; contraindicated for cervical spine placement.

Regulatory Classification

Identification

A spinal interlaminal fixation orthosis is a device intended to be implanted made of an alloy, such as stainless steel, that consists of various hooks and a posteriorly placed compression or distraction rod. The device is implanted, usually across three adjacent vertebrae, to straighten and immobilize the spine to allow bone grafts to unite and fuse the vertebrae together. The device is used primarily in the treatment of scoliosis (a lateral curvature of the spine), but it also may be used in the treatment of fracture or dislocation of the spine, grades 3 and 4 of spondylolisthesis (a dislocation of the spinal column), and lower back syndrome.

Predicate Devices

Submission Summary (Full Text)

{1}------------------------------------------------ Endius, Inc. 510(k) Premarket Notification Endius Minit PCT System March 14, 2006 K060683 # Section 5 - 510(k) Summary APR 1 2 2006 #### 5.1 Statement Pursuant to §513(i)(3)(A) of the Food, Drug, and Cosmetic Act, Endius, Inc. is required to submit with this Premarket Notification either an "... adequate summary of any information respecting safety and effectiveness or state that such information will be made available upon request of any person." Endius, Inc. chooses to submit a summary of information respecting safety and effectiveness. According to §513(i)(3)(B), "Any summary under subparagraph (A) respecting a device shall contain detailed information regarding data concerning adverse health effects ... " The summary regarding the adverse health effects of the modified device, Endius® Minit Posterior Cervical and Upper Thoracic Fixation System is provided below. ## 5.2 Submitter Endius, Inc. 23 West Bacon Street Plainville, MA. 02762 Establishment Registration #: 1057469 ## 5.3 Company Contact Christine Kuntz-Nassif Director, Regulatory Affairs/Quality Assurance (508) 643-0983 x114 cnassif(@endius.com #### 5.4 Device Name Proprietary Name: Endius Minit Posterior Cervical and Upper Thoracic Fixation System Classification Name: Spinal Interlaminal Fixation Orthosis Regulatory Class: II Product Code: KWP Regulation Number: 21 CFR 888.3050 {2}------------------------------------------------ Endius, Inc. 510(k) Premarket Notification Endius Minit PCT System March 14, 2006 #### 5.5 Predicate Devices Device Name(s) & 510(k) Number: - Medtronic Sofamor Danek VERTEX Reconstruction System, K052180 . - Synthes Spine Cervifix (K991089, K001864) and Starlock Systems . #### 5.6 Device Description The Endius Minit Posterior Cervical and Upper Thoracic Fixation System is a posterior system, which consists of a variety of sizes of rods, hooks, screws, multi-axial screws and connecting components, which can be rigidly locked to the rod in a variety of configurations. The Minit System is fabricated from medical grade titanium or titanium alloy that complies with ASTM F136. #### 5.7 Device Indications and Intended Use When intended to promote fusion of the cervical spine and the thoracic spine, (C1-T3), the Endius Minit Posterior Cervical and Upper Thoracic Fixation System is indicated for the following: DDD (neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, spinal stenosis, fracture, dislocation, failed previous fusion and/or tumors. #### Hooks and Rods The hooks and rods are also intended to provide stabilization to promote fusion following reduction of fracture/dislocation or trauma in the cervical/upper thoracic (C1-T3) spine. #### Screws/Connectors The use of screws is limited to placement in the T1-T3 in treating thoracic conditions only. Screws are not intended to be placed in the cervical spine. #### 5.8 Substantial Equivalence Documentation, including mechanical test results, has been provided which demonstrates that the proposed Endius Minit Posterior Cervical and Upper Thoracic Fixation System components are substantially equivalent to the Medtronic VERTEX Reconstruction System (K052180) and Synthes Spine Cervifix (K991089, K001864) and Starlock Systems. {3}------------------------------------------------ Image /page/2/Picture/1 description: The image shows the logo for the U.S. Department of Health and Human Services. The logo features a stylized depiction of an eagle or bird-like figure with three curved lines forming its body and wings. The logo is surrounded by a circular border containing the text "DEPARTMENT OF HEALTH AND HUMAN SERVICES U.S.A." Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 APR 1 8 2006 Endius, Inc. c/o Ms. Christine Kuntz-Nassif Director, RA/QA and Tissue Banking 23 West Bacon Sr. Plainville, Massachusetts 02762 Re: K060683 Trade/Device Name: Endius Minit Posterior Cervical and Upper Thoracic Fixation Regulation Number: 21 CFR 888.3050 Regulation Name: Spinal Interlaminal Fixation Orthosis Regulatory Class: Class II Product Code: KWP Dated: March 14, 2006 Received: March 16, 2006 Dear Ms. Kuntz-Nassif: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments. or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may. therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration. listing of devices. good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (PMA). it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA`s issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807): labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality {4}------------------------------------------------ Page 2- Ms. Christine Kuntz-Nassif systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at (240) 276-0120. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html. Sincerely yours, Helena Londo Mark N. Melkerson Director Division of General, Restorative and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {5}------------------------------------------------ Endius, Inc. 510(k) Premarket Notification Endius Minit PCT System March 14, 2006 ## Indications for Use #### 510(k) Number (if known): K06xxxx # Device Name: Endius® Minit Posterior Cervical and Upper Thoracic Fixation System #### Indications For Use: When intended to promote fusion of the cervical spine and the thoracic spine, (C1-T3), the Endius Minit Posterior Cervical and Upper Thoracic Fixation System is indicated for the following: DDD (neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, spinal stenosis, fracture, dislocation, failed previous fusion and/or tumors. #### Hooks and Rods The hooks and rods are also intended to provide stabilization to promote fusion following reduction of fracture/dislocation or trauma in the cervical/upper thoracic (C1-T3) spine. #### Screws/Connectors The use of screws is limited to placement in the T1-T3 in treating thoracic conditions only, Screws are not intended to be placed in the cervical spine. X Prescription Use (Part 21 CFR 801 Subpart D) AND/OR Over-The-Counter Use (21 CFR 807 Subpart C) (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) | (Division Sign-Off) | |---------------------| |---------------------| Division of General, Restorative, and Neurological Devices | 510(k) Number | K060683 | |---------------|---------| |---------------|---------| | Page 1 of 1 | 000010 | |-------------|--------| |-------------|--------|
Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...