The Legacy Abutment System is intended for use with dental implants in the maxillary and/or mandibular arches to provide support for crowns, bridges, or overdentures for edentulous or partially edentulous patients. The Legacy Abutment System is compatible with implants that have mating diameters, lead-in bevels, internal hex sizes, and 1-72UNF internal threads, as shown in the Zimmer Dental Tapered Screw-Vent Surgical Manual. Implant Direct LLC will monitor the compatible implants for modifications to ensure future compatibility. In the event of any modification, Implant Direct LLC will either modify the Legacy abutment to ensure compatibility, or cease claiming compatibility to the modified Zimmer Dental Screw-Vent implants.
Device Story
Legacy Abutment System consists of titanium alloy components (cement-retained and screw-retained) designed to interface with specific Zimmer Dental Tapered Screw-Vent implants; provides foundation for dental prosthetics (crowns, bridges, overdentures). Used by dental clinicians in clinical settings. Components include straight, scalloped, and angled bodies with varying cuff heights/diameters to match implant interfaces. Device functions as mechanical support post; no electronic or software components. Clinician selects appropriate abutment based on patient anatomy and implant site; secures to implant via internal hex and screw mechanism. Benefits include restoration of dental function and aesthetics for patients with missing teeth.
Clinical Evidence
No clinical data. Substantial equivalence is based on design comparison and technological characteristics.
Indicated for edentulous or partially edentulous patients requiring support for crowns, bridges, or overdentures in maxillary or mandibular arches.
Regulatory Classification
Identification
An endosseous dental implant abutment is a premanufactured prosthetic component directly connected to the endosseous dental implant and is intended for use as an aid in prosthetic rehabilitation.
Special Controls
*Classification.* Class II (special controls). The guidance document entitled “Class II Special Controls Guidance Document: Root-Form Endosseous Dental Implants and Endosseous Dental Implant Abutments” will serve as the special control. (See § 872.1(e) for the availability of this guidance document.)
{0}------------------------------------------------
Image /page/0/Picture/0 description: The image is a logo for Implant Direct LLC. The logo features a large letter "D" with a dental implant integrated into the left side of the "D". To the right of the "D" is the text "Implant Direct LLC" in a bold, sans-serif font. Below the logo is the website address "www.implantdirect.com".
06 0063
CONFIDENTIAL Legacy Abutment System
K.V. + 0.0006
510(K) SUMMARY
Company Name: Implant Direct LLC Address: 27030 Malibu Hills Road Calabasas Hills CA 91301 Telephone Number: (818) 444-3300 Fax Number: (818) 444-3408 Registration Number: 3001617766 Submitter's Name: Leslie Terry Contact Person: Patty McMahon Date Summary Prepared: January 5, 2006 - amended May 3, 2006
## Classification Name: Abutment, Implant, Dental, Endosseous Common/Usual Name: Endosseous dental implant abutment Device Trade Name: Legacy Abutment System
The primary device used for comparison in this summary is the Screw-Vent Dental Implant System (K011028).
### 1. Description:
The Legacy Abutment System consists of cement retained and screw-retained components. All abutments have the same identical interface diameters as the predicate abutments to function with the corresponding mating Screw-Vent Implants manufactured by Zimmer Dental. The cement retained abutments are offered in a straight body with a straight or scalloped prosthetic margin and in an angled body with a scalloped prosthetic margin. The screw-retained abutments are offered in different cuff diameters and heights to accommodate for the different implant interfaces and tissue heights.
### 2. Intended Use:
The Legacy Abutment System is intended for use with dental implants in the maxillary and/or mandibular arches to provide support for crowns, bridges, or overdentures for edentulous or partially edentulous patients.
The Legacy Abutment System is compatible with implants that have mating diameters, lead-in bevels, internal hex sizes, and 1-72UNF internal threads, as shown in the Zimmer Dental Tapered Screw-Vent Surgical Manual.
Implant Direct LLC will monitor the compatible implants for modifications to ensure future compatibility. In the event of any modification, Implant Direct LLC will either modify the Legacy abutment to ensure compatibility, or cease claiming compatibility to the modified Zimmer Dental Screw-Vent implants.
{1}------------------------------------------------
### 3. Technological Characteristics:
The Legacy abutments provide support for crowns, bridges, or overdentures in edentulous or partially edentulous patients for cement retained and screw retained restorations following the same preparation principals as the predicate devices. The Legacy abutments have similar technological characteristics and the same intended use as the predicate device. The Legacy abutments are packaged non-sterile for sale unlike the predicate devices packaged sterile. The Straight, Scalloped, and Angled Abutments are designed to function as a foundation for cemented restorations. The Screw-Retained abutments are designed to function as a foundation for scrow-retained restoration.
### 4. Comparison Analysis:
The overall designs of the Legacy Abutment System are similar to the predicate devices. The following Tables 1, 2, 3 summarize the predicate device comparison analyses with the Legacy Abutments.
| Technological<br>Characteristics | Legacy Straight and Scalloped<br>Abutments | Predicate Device:<br>Screw Vent Dental Implant<br>System (K011028) |
|--------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------|
| Intended Use | To be used as a post to support the<br>cemented prostheses | To be used as a post to<br>support the cemented<br>prostheses |
| Indication | For single or multiple restorations | For single or multiple<br>restorations |
| General Design | Hex engaging post with a prosthetic<br>margin | Hex engaging post without a<br>prosthetic margin |
| Cuff Diameters | 4.5, 5.7, and 6.5 mm | 3.5, 4.5, 5.7, and 6.5 mm |
| Implant/abutment<br>Interface<br>diameters | 3.5, 4.5, and 5.7mm | 3.5, 4.5, and 5.7mm |
| Material | Titanium Alloy | Titanium Alloy |
| Packaging | Scalloped Abutments: Screw mount<br>inside a vial closed with a cap<br>Straight Abutments:<br>The abutments are attached to a<br>plastic transfer/holder engaged within<br>an inner vial. The inner vial, along<br>with a screw-mount containing the<br>temporary coping, will be placed<br>within a larger outer vial and closed<br>with a vial cap. | Screw mount inside a vial<br>closed with a cap |
| Sterilization | Non-sterile | Sterile |
Table 1: Legacy Cement Retained Straight and Scalloped Abutments
{2}------------------------------------------------
:
: -
| Technological<br>Characteristics | Legacy Angled Abutments | Predicate Device:<br>Screw Vent Dental Implant<br>System (K011028) |
|----------------------------------|------------------------------------------------------|--------------------------------------------------------------------|
| Intended Use | To be used as a post to support the<br>prostheses | To be used as a post to<br>support the prostheses |
| Indication | For single or multiple restorations | For single or multiple<br>restorations |
| General Design | Hex engaging angled post with a<br>prosthetic margin | Hex engaging angled post<br>without prosthetic margin |
| Material | Titanium Alloy | Titanium Alloy |
| Packaging | Screw mount inside a vial closed with<br>a cap | Screw mount inside a vial<br>closed with a cap |
| Sterilization | Non-sterile | Sterile |
## Table 2: Legacy Cement Retained Angled Abutments
### Table 3: Legacy Screw Retained Abutments
| Technological<br>Characteristics | Legacy Screw-Retained Abutments | Predicate Device:<br>Screw Vent Dental Implant<br>System (K011028) |
|----------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------|
| Intended Use | Screw retained restoration | Screw retained restoration |
| Indication | Multiple unit application | Multiple unit application |
| General Design | One-piece abutment that screws inside the implant | One-piece abutment that screws inside the implant |
| Material | Titanium Alloy | Titanium Alloy |
| Packaging | Attached to a plastic transfer/holder engaged within an inner vial. The inner vial, along with a screw-mount containing the temporary coping, will be placed within a larger outer vial and closed with a vial cap | Screw mount inside a vial closed with a cap |
| Sterilization | Non-sterile | Sterile |
### 5. CONCLUSION
The evaluation of the Legacy Abutment System does not raise any additional concerns regarding safety and effectiveness and therefore is considered substantially equivalent to the predicate device.
... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
{3}------------------------------------------------
Image /page/3/Picture/1 description: The image shows the seal of the Department of Health and Human Services (HHS). The seal is circular and contains the HHS logo, which is a stylized caduceus. The words "DEPARTMENT OF HEALTH AND HUMAN SERVICES. USA" are written around the top of the circle.
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
MAY 19 2006
Ms. Leslie Terry Implant Direct, LLC 27030 Malibu Hills Road Calabasas Hills, California 91301
Re: K060063
Trade/Device Name: Legacy Abutment System Regulation Number: 21 CFR 872.3630 Regulation Name: Endosseous Dental implant Regulatory Class: II Product Code: NHA Dated: May 3, 2006 Received: May 4, 2006
Dear Ms. Terry:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
{4}------------------------------------------------
## Page 2 - Ms. Terry
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at (240) 276-0115. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html.
Sincerely yours,
Chi-Lien, Ph.D.
Chiu Lin, Ph.D. Director Division of Anesthesiology, General Hospital, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{5}------------------------------------------------
# Indications for Use
510(k) Number (if known): K060063
Device Name: Legacy Abutment System
Indications for Use:
The Legacy Abutment System is intended for use with dental implants in the maxillary and/or mandibular arches to provide support for crowns, bridges, or overdentures for edentulous or partially edentulous patients.
The Legacy Abutment System is compatible with implants that have mating diameters, lead-in bevels, internal hex sizes, and 1-72UNF internal threads, as shown in the Zimmer Dental Tapered Screw-Vent Surgical Manual.
Implant Direct LLC will monitor the compatible implants for modifications to ensure future compatibility. In the event of any modification, Implant Direct LLC will either modify the Legacy abutment to ensure compatibility, or cease claiming compatibility to the modified Zimmer Dental Screw-Vent implants.
X Prescription Use (Part 21 CFR 801 Subpart D)
AND/OR
Over-The-Counter Use (21 CFR 801 Subpart C)
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Susan Kunn
Vision Sign-Off
investion of Anesthesiology, Genemaldessives, of CDRH, Office of Device Evaluation (ODE) Infaction Control, Dental Devices
Number: 185600623
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Guidance alerts
New and changed FDA guidance documents, emailed as a daily digest.
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the ? button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only Software as a Medical Device, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (Software as a Medical Device), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.