MAGBODY DT-1200, DT-1200T, DT-1200M, DT-1200PT, DT-1200PM

K053285 · Durtech System Corp. · IPF · Jan 5, 2006 · Physical Medicine

Device Facts

Record IDK053285
Device NameMAGBODY DT-1200, DT-1200T, DT-1200M, DT-1200PT, DT-1200PM
ApplicantDurtech System Corp.
Product CodeIPF · Physical Medicine
Decision DateJan 5, 2006
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 890.5850
Device ClassClass 2
AttributesTherapeutic, 3rd-Party Reviewed

Intended Use

The DT-1200 series is a multifunction electrotherapy device with various treatment modes that allow for neuromuscular electrical stimulation (EMS) and transcutaneous electrical nerve stimulation (TENS). As a EMS device, (available for DT-1200, DT-1200M and DT-1200PM) the DT-1200 is indicated for the following conditions: - Relaxation of muscle spasms - Prevention or retardation of disuse atrophy - Increasing local blood circulation - Muscle re-education - Immediate post-surgical stimulation of calf muscles to prevent venous thrombosis - Maintaining or increasing range of motion As a TENS device, (available for DT-1200T and DT-1200T and DT-1200PT) the DT-1200 is indicated for the following conditions: - Symptomatic relief and management of chronic, intractable pain - Adjunctive treatment for post-surgical and post-trauma acute pain

Device Story

DT-1200 series is a multifunction electrotherapy device providing EMS and TENS modalities. Device delivers electrical stimulation via electrodes to target tissues. Used in clinical settings by healthcare professionals for pain management and muscle rehabilitation. Output affects muscle contraction or nerve signaling to achieve therapeutic goals like spasm reduction or pain relief. Benefits include improved circulation, atrophy prevention, and pain management.

Clinical Evidence

No clinical data provided; substantial equivalence based on technological characteristics and intended use.

Technological Characteristics

Multifunction electrotherapy device; provides EMS and TENS stimulation modes. Class II device (21 CFR 890.5850).

Indications for Use

Indicated for patients requiring neuromuscular electrical stimulation (EMS) for muscle spasm relaxation, disuse atrophy prevention, local blood circulation increase, muscle re-education, post-surgical calf stimulation to prevent venous thrombosis, and range of motion maintenance. Also indicated for patients requiring transcutaneous electrical nerve stimulation (TENS) for symptomatic relief of chronic intractable pain and adjunctive treatment of post-surgical/post-trauma acute pain.

Regulatory Classification

Identification

A powered muscle stimulator is an electrically powered device intended for medical purposes that repeatedly contracts muscles by passing electrical currents through electrodes contacting the affected body area.

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ DEPARTMENT OF HEALTH & HUMAN SERVICES Image /page/0/Picture/1 description: The image shows the logo for the U.S. Department of Health and Human Services. The logo consists of a stylized eagle with three lines forming its body and wings. The eagle is facing to the right. The text "DEPARTMENT OF HEALTH AND HUMAN SERVICES USA" is arranged in a circular pattern around the eagle. Public Health Service Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 2006 JAN 5 2006 DURTECH System Corp. c/o Mr. Marc M. Mouser Underwriters Labratories Inc. 2600 N.W. Lake Road Camas, Washington 98607 Re: K053285 Trade/Device Name: DT-1200 series Regulation Number: 21 CFR 890.5850 Regulation Name: Powered Muscle stimulator Regulatory Class: II Product Codes: IPF, GZJ Dated: December 20, 2005 Received: December 21, 2005 Dear Mr. Mouser: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807): labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (OS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. {1}------------------------------------------------ ## Page 2 - Mr. Mouser This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at (240) 276-0120. Also, please note the regulation entitled, OMisbranding by reference to premarket notification (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638 2041 or (301) 443 6597 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html. Sincerely yours, Signature Sor Mark N. Melkerson Acting Director Division of General, Restorative and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {2}------------------------------------------------ ## Indication for Use 510(K) Number (if known): 1053285 Device Name: DT-1200 series Indication For Use: The DT-1200 series is a multifunction electrotherapy device with various treatment modes that allow for neuromuscular electrical stimulation (EMS) and transcutaneous electrical nerve stimulation (TENS). As a EMS device, (available for DT-1200, DT-1200M and DT-1200PM) the DT-1200 is indicated for the following conditions: - · Relaxation of muscle spasms - · Prevention or retardation of disuse atrophy - Increasing local blood circulation - · Muscle re-education - Immediate post-surgical stimulation of calf muscles to prevent venous thrombosis - Maintaining or increasing range of motion As a TENS device, (available for DT-1200T and DT-1200T and DT-1200PT) the DT-1200 is indicated for the following conditions: - · Symptomatic relief and management of chronic, intractable pain - Adjunctive treatment for post-surgical and post-trauma acute pain Prescription Use X AND/OR (Part 21 CFR 801 Subpart D) Over-The-Counter Use (21 CFR 801 Subpart C) ## (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUED ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) **(Division Sign-Off)** Division of General, Restorative, and Neurological Devices **510(k) Number** K053285
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...