CONMED SYSTEM MODEL 2450 ELECTROSURGICAL GENERATOR

K052009 · Conmed Corporation · GEI · Sep 28, 2005 · General, Plastic Surgery

Device Facts

Record IDK052009
Device NameCONMED SYSTEM MODEL 2450 ELECTROSURGICAL GENERATOR
ApplicantConmed Corporation
Product CodeGEI · General, Plastic Surgery
Decision DateSep 28, 2005
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 878.4400
Device ClassClass 2
AttributesTherapeutic

Indications for Use

The System 2450 is a general-purpose electrosurgical generator used in coniunction with an electrosurgical accessory handpiece for delivery of RF (radio frequency) electrosurgical current through an accessory electrode for cutting and coagulation at the operative site.

Device Story

System 2450 is an electrosurgical generator providing high-frequency (HF) current to accessory handpieces for tissue cutting and coagulation. Operation involves drawing an electrode across tissue for cutting, or holding it in contact (desiccation) or at a distance (fulguration) for coagulation. Used in clinical settings by healthcare professionals. The device provides alarms for patient safety; operators manually select modes and output settings. Output characteristics are designed to be equivalent to previously cleared generators, facilitating standard surgical procedures.

Clinical Evidence

No clinical data. Substantial equivalence is based on bench testing, compliance with international safety standards (IEC 60601 series), and verification/validation of software and output performance.

Technological Characteristics

Electrosurgical generator; HF energy source. Complies with ANSI/AAMI HF-18, IEC 60601-1, 60601-1-1, 60601-1-2, 60601-1-4, 60601-1-8, 60601-2-2, UL60601-1, ISO 14971, and ISO 10993. Features operator-controlled modes and output settings with integrated patient safety alarms.

Indications for Use

Indicated for general-purpose electrosurgical cutting and coagulation at the operative site using RF current delivered via accessory handpieces and electrodes.

Regulatory Classification

Identification

An electrosurgical cutting and coagulation device and accessories is a device intended to remove tissue and control bleeding by use of high-frequency electrical current.

Predicate Devices

Submission Summary (Full Text)

{1}------------------------------------------------ 2 = 2 8 2005 sa002 510(k) Premarket Notification CONMED System 2450 ESU ## Summary of Safety and Effectiveness | Submitted by: | CONMED Electrosurgery Division<br>14603 East Fremont Avenue<br>Centennial, CO 80112 USA<br>Telephone: 303-699-7600<br>Facsimile: 303-699-9854 | |----------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | Contact Person: | Pamela L. Vetter | | Date Prepared: | July 21, 2005 | | Proprietary Name: | CONMED System 2450 ESU | | Common Name: | Electrosurgical Unit and Accessories | | Classification Name: | Electrosurgical Cutting and Coagulation Device and accessories<br>21 CFR 878.4400<br>79 GEI | | Predicate Device: | CONMED Sabre 2400 ESU, K905654, cleared March 18, 1991<br>CONMED System 5000 ESU, K020186, cleared April 12, 2002<br>Valleylab Force FX™ ESU. K944602. cleared June 5. 1995 | Device Description: The System 2450 is an electrosurgical generator with the basic modes of operation being conventional electrosurgical cutting and coagulation. When cutting, the edge of the electrode is drawn across the tissue while electrosurgical energy is being applied. When coagulating, the accessory electrode may be held in contact with the tissue for desiccation or separated from the tissue by distance for fulguration to achieve the desired result. The device consists of an electrosurgical generator unit to supply high frequency (HF) electrosurgical current to accessory handpieces to produce the therapeutic effect. The device utilizes previously cleared/marketed and required accessories. Intended Use of Device: The System 2450 is a general-purpose electrosurgical generator used in coniunction with an electrosurgical accessory handpiece for delivery of RF (radio frequency) electrosurgical current through an accessory electrode for cutting and coagulation at the operative site. Technological Characteristics: The proposed device is equivalent to the identified predicate devices with respect to technological characteristics and function. The device has been designed to comply with the applicable sections of ANSI/AAMI American National Standard for Electrosurgical Devices HF-18, the International Electrotechnical Commission Standard for Electrosurgical Devices, IEC 60601-1, 60601-1-1, 60601-1-2, 60601-1-4, 60601-1-8, 60601-1-8, 60601-2-2, Underwriter's Laboratory UL60601-1, Risk Management ISO 14971 and Biocompatibility ISO 10993. Software for the System 2450 ESU will be validated in accordance with internal ConMed Electrosurgery procedures including the FDA guidance "General Principles of Software Validation". The level of concern for the ConMed System 2450 is "Moderate" as defined in the FDA guidance for the Content of Premarket Submissions for Software Contained in Medical Devices. This is based on the following considerations: - . The System 2450 software will be validated and verified according to documented procedures, which include, but are not limited to System Level Hazard Analysis, peer review of software design and software module testing. All validation and verification activities will be completed prior to commercial distribution; - . Output characteristics are equivalent to the values for other previously cleared electrosurgical generators; - . The operator controls the use of the device; - The device provides alarms for conditions that could pose a risk to the patient; . - The operator sets the appropriate mode and output settings for the device. ● {2}------------------------------------------------ Image /page/1/Picture/1 description: The image shows the logo for the U.S. Department of Health and Human Services. The logo consists of a circular seal with the text "DEPARTMENT OF HEALTH AND HUMAN SERVICES . USA" around the perimeter. Inside the circle is a stylized symbol that resembles a human figure with three flowing lines representing the body and head. Public Health Service Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 SEP 2 8 2005 Ms. Pamela Vetter Manager of Regulatory Affairs CONMED Electrosurgery 14603 East Fremont Avenue Centennial, Colorado 80112 Re: K052009 Trade/Device Name: CONMED SYSTEM 2450 ESU Regulation Number: 21 CFR 878.4400 Regulation Name: Electrosurgical cutting and coagulation device and accessories Regulatory Class: II Product Code: GEI Dated: July 21, 2005 Received: July 25, 2005 Dear Ms. Vetter: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. {3}------------------------------------------------ This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at (240) 276-0115. Also, please note the regulation entitled. "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html Sincerely yours, Mark McMillken Mark N. Melkerson Acting Director Division of General, Restorative and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {4}------------------------------------------------ 510(k) Number (if known): K 0 52 00 9 Device Name: _________________________________________________________________________________________________________________________________________________________________ CONMED SYSTEM 2450 ESU Indications for Use: General-purpose electrosurgical generator used in conjunction with an electrosurgical accessory handpiece for delivery of RF (radio frequency) electrosurgical current through an accessory electrode for cutting and coagulation at the operative site. Prescription Use (Per 21 CFR 801.109) OR Over-The-Counter (PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) Mark A. Mikkelsen (Division Sign-Off) Division of General, Restorative, and Neurological Devices 510(k) Number
Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...