K050163 · Henke Sass Wolf of America, Inc. · GCJ · Mar 24, 2005 · Gastroenterology, Urology
Device Facts
Record ID
K050163
Device Name
HENKE SASS WOLF OF AMERICA BARIATRIC LAPAROSCOPE
Applicant
Henke Sass Wolf of America, Inc.
Product Code
GCJ · Gastroenterology, Urology
Decision Date
Mar 24, 2005
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 876.1500
Device Class
Class 2
Attributes
Therapeutic
Indications for Use
The Henke Sass Wolf of America HSW Bariatric Laparoscope is intended to be used in general laparoscopic surgery. Laparoscopic surgery is a means of performing diagnostic and therapeutic surgical procedures intra-abdominally using equipment that minimizes surgical invasiveness. Rather than creating large incisions to gain access to surgical sites, surgeons view inside the body and operate by using instruments inserted through small skin punctures (inserted through the laparoscope or through another small incision). This includes, but is not limited to such uses as gallbladder and appendix removal, hernia repair, and examination of the abdominal cavity, appendix, gallbladder, and liver. Bariatric laparoscopes are intended to be used to perform surgical procedures on morbidly obese segments of the patient population.
Device Story
Rigid endoscope for minimally invasive abdominal surgery; provides visualization of internal anatomy. Input: optical images via lens system; Output: visual feed for surgeon. Used in OR by surgeons. Device features extended shaft length (up to 550mm) to accommodate morbidly obese patients. Connects to conventional light-guides. Surgeon views anatomy through eyepiece or connected camera system to guide surgical instruments. Facilitates minimally invasive access, reducing incision size compared to open surgery.
Clinical Evidence
Bench testing only. Compliance with ISO 10993-1, -5, -12 for biological evaluation; IEC 601-2-18 for electrical safety; and AAMI/ISO standards for sterilization (EtO, Steris, Sterrad).
Technological Characteristics
Rigid laparoscope; 5-10mm diameter; 280-550mm length; 0, 30, 45-degree view angles; 75-degree field of view. Materials: 300 series stainless steel shaft/body/sidearm; PEEK eyepiece; glass or sapphire lenses. Connects to standard light-guides. Sterilizable via EtO, Steris, or Sterrad.
Indications for Use
Indicated for general laparoscopic diagnostic and therapeutic surgical procedures, including gallbladder/appendix removal, hernia repair, and abdominal cavity examination. Specifically indicated for use in morbidly obese patient populations.
Regulatory Classification
Identification
An endoscope and accessories is a device used to provide access, illumination, and allow observation or manipulation of body cavities, hollow organs, and canals. The device consists of various rigid or flexible instruments that are inserted into body spaces and may include an optical system for conveying an image to the user's eye and their accessories may assist in gaining access or increase the versatility and augment the capabilities of the devices. Examples of devices that are within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes, flexible or rigid choledochoscopes, colonoscopes, diagnostic cystoscopes, cystourethroscopes, enteroscopes, esophagogastroduodenoscopes, rigid esophagoscopes, fiberoptic illuminators for endoscopes, incandescent endoscope lamps, biliary pancreatoscopes, proctoscopes, resectoscopes, nephroscopes, sigmoidoscopes, ureteroscopes, urethroscopes, endomagnetic retrievers, cytology brushes for endoscopes, and lubricating jelly for transurethral surgical instruments. This section does not apply to endoscopes that have specialized uses in other medical specialty areas and that are covered by classification regulations in other parts of the device classification regulations.
Special Controls
*Classification* —(1)*Class II (special controls).* The device, when it is an endoscope disinfectant basin, which consists solely of a container that holds disinfectant and endoscopes and accessories; an endoscopic magnetic retriever intended for single use; sterile scissors for cystoscope intended for single use; a disposable, non-powered endoscopic grasping/cutting instrument intended for single use; a diagnostic incandescent light source; a fiberoptic photographic light source; a routine fiberoptic light source; an endoscopic sponge carrier; a xenon arc endoscope light source; an endoscope transformer; an LED light source; or a gastroenterology-urology endoscopic guidewire, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.(2) Class I for the photographic accessories for endoscope, miscellaneous bulb adapter for endoscope, binocular attachment for endoscope, eyepiece attachment for prescription lens, teaching attachment, inflation bulb, measuring device for panendoscope, photographic equipment for physiologic function monitor, special lens instrument for endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and cleaning brush for endoscope. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807of this chapter, subject to the limitations in § 876.9.
Predicate Devices
Henke Sass Wolf GmbH HSW Laparoscopy Set (K941967)
{0}------------------------------------------------
41
MAR 2 4 2005
Henke Sass Wolf of America
44 Southbridge Rd.
# KOSO 163
### SAFETY & EFFECTIVENESS DATA SUMMARY
| | Dudley, MA 01571 |
|------------------------------------|-----------------------------------------------------------|
| Submission Correspondent: | Lyle Howard Corporation |
| | 203 Main Street, PMB 166 |
| | Flemington, NJ 08822 |
| | Attention: Lynette Howard |
| Classification Name: | Endoscope & Accessories |
| Common / Usual Name: | Bariatric Laparoscope |
| Proprietary Name: | Henke Sass Wolf Bariatric Laparoscope |
| Establishment Registration Number: | 1222997 |
| Classification: | Class II, Reg. # 876.1500, GCJ Gastroenterology - Urology |
Performance Standards: No performance standards have been developed for this device.
Substantial Equivalence:
Submitters Name, Address & Phone Number:
The Henke Sass Wolf of America Bariatric Laparoscopes are substantially equivalent to the Henke Sass Wolf GmbH - K941967 and the Stryker -K993045 in design, materials, methods of construction and intended use.
The intended use of the devices to which we claim substantial equivalence:
The Henke Sass Wolf of America HSW Laparoscopy Set (K941967) is intended to be used in general laparoscopic surgery. Laparoscopic surgery is a means of performing diagnostic and therapeutic surgical procedures intraabdominally using equipment that minimizes surgical invasiveness. Rather than creating large incisions to gain access to surgical sites, surgeons view inside the body and operate by using instruments inserted through small skin punctures (inserted through the laparoscope or through another small incision). This includes, but is not limited to such uses as gallbladder and appendix removal, hernia repair, and examination of the abdominal cavity, appendix, gallbladder, and liver.
1/3
{1}------------------------------------------------
KOSO163
The Stryker Bariatric Laparoscopes (K993045) are intended to be used by surgeons in diagnostic and therapeutic procedures. Laparoscopic minimally invasive procedures are performed in the abdominal cavity by means of small skin punctures that allow the insertion of the laparoscope and laparoscopic instruments. This includes, but is not limited to such uses as gallbladder and appendix removal, hernia repair, gastric bypass, laparoscopic Nissen and examination of the abdominal cavity, appendix, gallbladder and liver.
Bariatric laparoscopes allow surgeons to perform procedures on morbidly obese segments of the patient population.
Testing conducted to assure safety and effectiveness include but is not limited to:
Biological Evaluation of Medical Devices - ISO 10993-1, ISO 10993-5, ISO 10993-12 Electrical Safety Requirements as per IEC 601-2-18 as a type BF or Type CF applied as part of medical electrical equipment. AAMI / ISO Standards for Sterilization of Medical Devices
Proposed devices have successfully met the requirements of the above.
Description of the new device:
The Henke Sass Wolf of America's Bariatric Laparoscope is identical in terms of materials and modes of construction, optical performance and safety to Henke Sass Wolf GmbH HSW Laparoscopy Set - K941967 and the Stryker - K993045. This Bariatric version is longer (up to 550mm) so that it is capable of performing the same types of procedures on morbidly obese segments of the patient population.
| Diameter | 5mm - 10mm |
|-------------------|----------------------------|
| Length | 280mm to 550mm |
| Direction of View | 0, 30, 45 Degrees |
| Field of View | 75 Degrees |
| Shaft | 300 Series Stainless Steel |
| Body | Stainless Steel |
| Sidearm | Stainless Steel |
| Eyepiece | P.E.E.K. |
| Lenses | Glass or Sapphire |
Specifications / Materials:
{2}------------------------------------------------
Adapters for connection to all conventional light-guides are supplied as standard.
The device is intended to be sterilized prior to use. The Bariatric Laparoscopes are designed to facilitate cleaning and disinfection as were the predicate devices. There is no difference in design and material that would impact the sterilization validation conducted for the HSW predicate device.
Instructions for cleaning and sterilization are included in the instructions for use. Sterilization and disinfection validation for predicate devices included EtO, Steris, and Sterrad is performed to assure an SAL of 10-6 per AAMI / ISO Standards.
#### Intended Use:
The Henke Sass Wolf of America HSW Bariatric Laparoscope is intended to be used in general laparoscopic surgery. Laparoscopic surgery is a means of performing diagnostic and therapeutic surgical procedures intraabdominally using equipment that minimizes surgical invasiveness. Rather than creating large incisions to gain access to surgical sites, surgeons view inside the body and operate by using instruments inserted through small skin punctures (inserted through the laparoscope or through another small incision). This includes, but is not limited to such uses as gallbladder and appendix removal, hernia repair, and examination of the abdominal cavity, appendix, gallbladder, and liver.
Bariatric laparoscopes are intended to be used to perform surgical procedures on morbidly obese segments of the patient population.
Caution: Federal (USA) law restricts this device to sale, distribution, and use by, or on the order of, a physician.
Safety and Efficacy Information:
There are no changes in the material used in the manufacturing process, which would affect the Safety and Effectiveness of the proposed device.
The HSW Bariatric Laparoscope does not introduce new issues when compared to its predicate devices or uses. Therefore, the HSW Bariatric Laparoscope is substantially equivalent to its predicate devices.
{3}------------------------------------------------
Image /page/3/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a circular seal with the words "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" arranged around the perimeter. Inside the circle is a stylized emblem featuring three abstract shapes resembling waves or curves, stacked on top of each other. The logo is black and white.
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
MAR 2 4 2005
Henke Sass Wolf of America, Inc. c/o Ms. Lynette L. Howard Lyle Howard Corporation 203 Main Street, PMB 166 Flemington, New Jersey 08822
Re: K050163
Trade/Device Name: Henke Sass Wolf Bariatric Laparoscope Regulation Number: 21 CFR 876.1500 Regulation Name: Endoscope and accessories Regulatory Class: II Product Code: GCJ Dated: March 3, 2005 Received: March 4, 2005
Dear Ms. Howard:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or (o eonimores provision in accordance with the provisions of the Federal Food. Drug. and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). and ocometherefore, market the device, subject to the general controls provisions of the Act. The r ou may) and survisions of the Act include requirements for annual registration. Iisting of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it 11 70ar artise to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination docs not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
{4}------------------------------------------------
Page 2 - Ms. Lynette L. Howard
This letter will allow you to begin marketing your device as described in your Section 510(k) I mo lotter will as a maing of substantial equivalence of your device of your device to a legally prematics noticate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please 11 you a the Office of Compliance at (240) 276-0115. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Marcharts, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html.
Sincerely yours,
Ech
Miriam C. Provost, h.D. Acting Director Division of General, Restorative and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{5}------------------------------------------------
## Indications for Use
510(k) Number (if known): k (150163
#### Device Name: Henke Sass Wolf Bariatric Laparoscope
Indications For Use:
The Henke Sass Wolf of America HSW Bariatric Laparoscope is intended to be used in general laparoscopic surgery. Laparoscopic surgery is a means of performing diagnostic and therapeutic surgical procedures intra-abdominally using equipment that minimizes surgical invasiveness. Rather than creating large incisions to gain access to surgical sites, surgeons view inside the body and operate by using instruments inserted through small skin punctures (inserted through the laparoscope or through another small incision). This includes, but is not limited to such uses as gallbladder and appendix removal, hernia repair, and examination of the abdominal cavity, appendix, gallbladder, and liver.
Bariatric laparoscopes are intended to be used to perform surgical procedures on morbidly obese segments of the patient population.
Prescription Use × (Part 21 CFR 801 Subpart D) AND/OR
Over-The-Counter Use (21 CFR 807 Subpart C)
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Elich
Page 1 of
KOS0163
47