ACMI INVISIO ICN, MODELS ICN-0564 AND ICN-0565

K042225 · Acmi Corporation · FAJ · Sep 10, 2004 · Gastroenterology, Urology

Device Facts

Record IDK042225
Device NameACMI INVISIO ICN, MODELS ICN-0564 AND ICN-0565
ApplicantAcmi Corporation
Product CodeFAJ · Gastroenterology, Urology
Decision DateSep 10, 2004
DecisionSESE
Submission TypeSpecial
Regulation21 CFR 876.1500
Device ClassClass 2
AttributesTherapeutic

Indications for Use

The ACMI® INVISIO ICN (ICN) Digital Flexible CystoNephroscope System (which includes the ICN scope and Controller) is intended for use to examine body cavities, hollow organs and canals in the body, in the urinary tract, and can be used percutaneously to examine the interior of the kidney; and, using additional accessories, can be used to perform various diagnostic and therapeutic procedures.

Device Story

Flexible endoscope system; utilizes distal-tip CMOS sensor to capture visual data; transmits signals via shaft wiring to Camera Control Unit (CCU). CCU processes signals using internal PCBs and software to display images for clinician. Used in clinical settings (urology/surgery) for urinary tract and kidney examination; enables diagnostic/therapeutic procedures via working channel. Modifications from predicate include proximal handle redesign, reduced shaft diameter, removal of secondary active deflection, and minor software algorithm update. Clinician views real-time video on external display to guide navigation and perform interventions. Benefits include improved visualization for minimally invasive urological procedures.

Clinical Evidence

No clinical data provided. Substantial equivalence based on design, performance, and software specification comparisons to predicate device.

Technological Characteristics

Flexible endoscope with distal CMOS sensor; LED light source in handle; electrical connection to CCU. Features include reduced shaft diameter and modified proximal handle. Software-based image processing via CCU. Sterilization/materials not specified beyond general endoscope classification.

Indications for Use

Indicated for examination of urinary tract body cavities, hollow organs, and canals, including percutaneous examination of the kidney interior. Supports diagnostic and therapeutic procedures when used with accessories. Prescription use only.

Regulatory Classification

Identification

An endoscope and accessories is a device used to provide access, illumination, and allow observation or manipulation of body cavities, hollow organs, and canals. The device consists of various rigid or flexible instruments that are inserted into body spaces and may include an optical system for conveying an image to the user's eye and their accessories may assist in gaining access or increase the versatility and augment the capabilities of the devices. Examples of devices that are within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes, flexible or rigid choledochoscopes, colonoscopes, diagnostic cystoscopes, cystourethroscopes, enteroscopes, esophagogastroduodenoscopes, rigid esophagoscopes, fiberoptic illuminators for endoscopes, incandescent endoscope lamps, biliary pancreatoscopes, proctoscopes, resectoscopes, nephroscopes, sigmoidoscopes, ureteroscopes, urethroscopes, endomagnetic retrievers, cytology brushes for endoscopes, and lubricating jelly for transurethral surgical instruments. This section does not apply to endoscopes that have specialized uses in other medical specialty areas and that are covered by classification regulations in other parts of the device classification regulations.

Special Controls

*Classification* —(1)*Class II (special controls).* The device, when it is an endoscope disinfectant basin, which consists solely of a container that holds disinfectant and endoscopes and accessories; an endoscopic magnetic retriever intended for single use; sterile scissors for cystoscope intended for single use; a disposable, non-powered endoscopic grasping/cutting instrument intended for single use; a diagnostic incandescent light source; a fiberoptic photographic light source; a routine fiberoptic light source; an endoscopic sponge carrier; a xenon arc endoscope light source; an endoscope transformer; an LED light source; or a gastroenterology-urology endoscopic guidewire, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.(2) Class I for the photographic accessories for endoscope, miscellaneous bulb adapter for endoscope, binocular attachment for endoscope, eyepiece attachment for prescription lens, teaching attachment, inflation bulb, measuring device for panendoscope, photographic equipment for physiologic function monitor, special lens instrument for endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and cleaning brush for endoscope. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807of this chapter, subject to the limitations in § 876.9.

In combination with the general controls of the FD&C Act, the integrated operating table-electromechanical surgical system is subject to the following special controls: 1. (1) Premarket clinical performance testing, or a combination of premarket clinical performance testing and postmarket surveillance (in accordance with special control (2)), must include the following: 1. (i) Objective performance measures (e.g., rate and number of conversions to other surgical modalities, rate of device related adverse events (including tissue injury, hematoma, and increased blood loss), and their severity, cause, and outcomes) must be reported with relevant descriptive comparator performance measures. 2. (ii) The data must demonstrate the performance of the device for providing accurate and precise control of attached surgical instruments in range of clinical conditions relevant to the device's intended use. 3. (iii) The test dataset must include data collected from a patient population representative of the intended patient population under anticipated conditions of use. 2. (2) Data obtained from postmarket surveillance must demonstrate, in consideration of the premarket data obtained in accordance with special control (1), that the device performs in accordance with special control (1), unless FDA determines, based on the totality of the premarket data, that data from postmarket surveillance is not required to demonstrate that the device performs as intended. Such postmarket surveillance must be conducted per a protocol determined appropriate by FDA to demonstrate that the device performs as intended (in consideration of the premarket data obtained in accordance with special control (1)), and must include initiation, enrollment, and reporting requirements to ensure timely periodic updates to FDA on post-market surveillance progress and outcomes. 3. (3) Animal performance testing must evaluate the extent of port site trauma due to repositioning of table during surgical procedures when utilizing robotic minimally invasive and laparoscopic approaches 4. (4) The device manufacturer must develop, and update as necessary, a device-specific use training program that ensures proper device setup/use/shutdown, accurate control of instruments to perform the intended surgical procedures, troubleshooting and handling during unexpected events or emergencies, and safe practices to mitigate use error. 5. (5) The device manufacturer may only distribute the device to facilities that implement and maintain the device-specific use training program and ensure that users of the device have completed the device-specific use training program. (6) Human factors assessment must demonstrate that the user can correctly use the device system across all intended use environments with the provided instructions and training materials, including patient access during normal operating conditions and emergency situations, and effects arising from the integrated nature of the operating table and robotic surgical arms. (7) Labeling must include: (i) A detailed summary of clinical performance testing conducted with the device, including study population, results, adverse events, and comparisons to any comparator groups identified; (ii) A statement in the labeling that the safety and effectiveness for the representative specific procedures was based on evaluation of the device as a surgical tool and did not include evaluation of outcomes related to the treatment of the patient's underlying disease or condition, unless FDA determines that it can be removed or modified based on clinical performance data submitted to FDA; (iii) Identification of compatible devices; (iv) The list of surgical procedures for which the device has been determined to be safe with clinical justification; (v) Reprocessing instructions for reusable components; (vi) A shelf life for any sterile components; (vii) A description of the device-specific use training program; (viii) A statement that the device is only for distribution to facilities that implement and maintain the device-specific use training program and ensure that users of the device have completed the device-specific use training program; and (ix) A summary of any completed postmarket surveillance data collected as required by special control (2), including updated labeling to accurately reflect outcomes observed in postmarket surveillance. (8) Non-clinical performance testing must demonstrate that the device performs as intended under anticipated conditions of use and must include: (i) Device motion accuracy and repeatability; (ii) System testing; (iii) Instrument reliability; (iv) Crosstalk; (v) Table motion control; (vi) Thermal effects on tissue; (vii) User-device interface performance; (viii) Workspace access testing; and (ix) Performance testing with compatible devices. (9) Software verification, validation, and hazard analysis must be performed. (10) Electromagnetic compatibility and electrical, thermal, and mechanical safety testing must be performed. (11) Performance data must demonstrate the sterility of all patient-contacting device components. (12) Performance data must support the shelf life of the device components provided sterile by demonstrating continued sterility and package integrity over the labeled shelf life. (13) Performance data must validate the reprocessing instructions for the reusable components of the device. (14) Performance data must demonstrate that all patient-contacting components of the device are biocompatible. (15) Performance data must demonstrate that all patient-contacting components of the device are non-pyrogenic. (16) The device manufacturer must submit a report to the FDA annually on the anniversary of initial marketing authorization for the device, until such time as FDA may terminate such reporting, which comprises the following information: (i) Cumulative summary, by year, of complaints and adverse events since date of initial marketing authorization; and (ii) Identification and rationale for changes made to the device, labeling, or device specific use training program, which did not require submission of a premarket notification during the reporting period.

Predicate Devices

Submission Summary (Full Text)

{0}------------------------------------------------ ACMI® INVISIO ICN ACMI Corporation 136 Turnpike Road Southborough, MA 01772 SEP 1 0 2004 Special 510(k) Notification Statement of Intended Use August 16, 2004 ## 510(k) Summary of Safety and Effectiveness ACMI Corporation ACMI® INVISIO ICN K04 2225 # General Information | Manufacturer: | ACMI Corporation<br>136 Turnpike Rd.<br>Southborough, MA 01772-2104 | |------------------------------------|---------------------------------------------------------------------------------------------------------------------------| | Establishment Registration Number: | 2020483 | | Contact Person: | Terrence E. Sullivan<br>Director, Regulatory Affairs | | Date Prepared: | August 16, 2004 | | Device Description | | | Classification Name: | Endoscope and accessories<br>(21 CFR 876.1500), Class II<br>Surgical camera and accessories<br>(21 CFR 878.4160), Class I | | Trade Name: | ACMI® INVISIO ICN | | Generic/Common Name: | Endoscope, Video Camera and accessories | | Predicate Device | | | | ACMI® ECN Video CystoNephroscope System | | | K030960 | ## Intended Uses The ACMI® INVISIO ICN (ICN) Digital Flexible CystoNephroscope System (which includes the ICN scope and Controller) is intended for use to examine body cavities, hollow organs and canals in the body, in the urinary tract, and can be used percutaneously to examine the interior of the kidney; and, using additional accessories, can be used to perform various diagnostic and therapeutic procedures. {1}------------------------------------------------ ACMI® INVISIO ICN CMI Corporation 136 Turnpike Road Southborough, MA 01772 Ko42225 Special 510(k) Notification Summary of Safety and Effectiveness August 16, 2004 ## Product Description Like the predicate ACMI® Electronic Video CystoNephroscope (ECN) System, the ACMI® INVISIO ICN (ICN) is a flexible endoscope that incorporates CMOS (complimentary medical oxide semi-conductor) sensor technology to generate an image. The ICN can be introduced either through the urethra into the bladder or through a percutaneous tract into the abdominal cavity or kidney. The ICN incorporates the same basic video imaging technology located in the endoscope as the predicate device. There is a miniature CMOS sensor located in the distal tip, wiring running through the endoscope shaft, a printed circuit board (PCB), a light-emitting diode (LED) light source located in the handle, and an electrical cord that connects the endoscope to the Camera Control Unit. Like the predicate device, the ICN uses the same Camera Control Unit (CCU) that contains printed circuits boards (PCBs), software, power supply and power cables to process and display the images transmitted by the camera. This Special 510(k) proposes modifications in the proximal handle design, a reduction in flexible shaft outer diameter, elimination of the secondary active deflection mechanism, and a minor software algorithm modification for the ACMI® INVISIO ICN. The indications for use, principles of operation, working channel length and diameter of the ACMI® INVISIO ICN remain the same as in the predicate device. #### Summary of Safety and Effectiveness The proposed modifications for the ACMI® INVISIO ICN, as described in this submission, are substantially equivalent to the predicate device. The proposed modification in design specifications, performance specifications, dimensional specifications, and software specifications are not substantial changes or modifications, and do not significantly affect the safety or efficacy of the devices. {2}------------------------------------------------ Image /page/2/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo features a stylized eagle with three stripes representing the department's mission. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged in a circular pattern around the eagle. Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 SEP 1 0 2004 Mr. Terrence E. Sullivan Director, Regulatory Affairs ACMI Corporation 136 Turnpike Road SOUTHBOROUGH MA 01772-2104 Re: K042225 Trade/Device Name: ACMI® INVISIO ICN Regulation Number: 21 CFR §876.1500 Regulation Name: Endoscope and accessories Product Codes: 78 FAJ and FGA Regulation Number: 21 CFR §878.4160 Regulation Name: Surgical camera and accessories Product Code: 79 FWF Regulatory Class: II Dated: August 16, 2004 Received: August 17, 2004 Dear Mr. Sullivan: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (sections 531-542 of the Act); 21 CFR 1000-1050. {3}------------------------------------------------ This letter will allow you to begin marketing your device as described in your Section 510(k) I his letter will allow you to ocgin mative of substantial equivalence of your device to a legally premarket notheation. The PDA mailing of cation for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please If you desire specific advice tor your dones on the following numbers, based on the regulation number at the top of the letter: | 8xx. 1xxx | (301) 594-4591 | |----------------------------------|----------------| | 876.2xxx, 3xxx, 4xxx, 5xxx | (301) 594-4616 | | 884.2xxx, 3xxx, 4xxx, 5xxx, 6xxx | (301) 594-4616 | | 892.2xxx, 3xxx, 4xxx, 5xxx | (301) 594-4654 | | Other | (301) 594-4692 | Additionally, for questions on the promotion and advertising of your device, please contact the Additionally, for questions on the presses on the regulation entitled, "Misbranding Other of Compliance at (501) 57 - 155 - 155 - 157.97) you may obtain. Other general by relerence to premation on the Act may be obtained from the Division of Small Information on your responsional and Consumer Assistance at its toll-free number (800) 638-2041 or Manutacturers, International and Octoballitter//www.fda.gov/cdrh/dsma/dsmamain.html. Sincerely yours, Nancy C. Brogdon Nancy C. Brogdon Director, Division of Reproductive, Abdominal and Radiological Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure - {4}------------------------------------------------ Special 510(k) Notification Statement of Intended Use August 16, 2004 Device Name: ACMI® INVISIO ICN K042225 510(k) Number: Indications for use: The ACMI® INVISIO ICN (ICN) Digital Flexible CystoNephroscope System (which includes the ICN scope and Controller) is intended for use to examine body cavities, hollow organs and canals in the body, in the urinary tract, and can be used nonew - ergans and mine the interior of the kidney; and, using additional accessories, can be used to perform various diagnostic and therapeutic procedures. (PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) Prescription Use: X _ OR Over-the-Counter Use: (Per 21 CFR 801.109) David A. Ingram (Division Sign-Off) Division of Reproductive, Ab and Radiological Devices 510(k) Number
Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...