K041585 · Algos, LC · MEB · Aug 26, 2004 · General Hospital
Device Facts
Record ID
K041585
Device Name
AUTOFUSER AMBULATORY INFUSION PUMP
Applicant
Algos, LC
Product Code
MEB · General Hospital
Decision Date
Aug 26, 2004
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 880.5725
Device Class
Class 2
Attributes
Therapeutic
Indications for Use
The AutoFuser family of ambulatory infusion pumps with integrated administration set, either separately or as part of a convenience kit, and its predicate devices are indicated for general infusion use. Routes of infusion include intravenous, percutaneous, subcutaneous, inter-arterial and epidural, and into intra-operative (soft tissue / body cavity) sites. Members of the AutoFuser family and the predicate devices are also intended for patient-controlled infusion using the integrated bolus button. General infusion uses include continuous infusion of a local anesthetic near a nerve for regional anesthesia and pain management for pre-operative, perioperative and postoperative surgery.
Device Story
AutoFuser is a disposable, ambulatory elastomeric infusion pump; utilizes silicone balloon as both fluid reservoir and pressure/energy source; provides continuous fluid delivery via fixed-rate administration set. Family includes standard models and Patient Medication Control Module (PCM) models allowing patient-administered bolus with fixed lockout time. Used in hospital, home, or alternative care sites; operated by clinicians or patients. Flow rate controlled by glass orifice or PVC tubing. Device provides continuous infusion of local anesthetics or general fluids; bolus feature allows patient-controlled pain management. Benefits include ambulatory delivery of medication for regional anesthesia and post-surgical pain management.
Clinical Evidence
No clinical data provided. Substantial equivalence is based on bench testing and comparison of technological characteristics, materials, and intended use to legally marketed predicate devices.
Technological Characteristics
Elastomeric infusion pump; silicone balloon reservoir/energy source; glass orifice or PVC tubing flow control; integrated administration set. Fluid path materials conform to ISO 10993 Part 1. Disposable, single-patient use. Ambulatory form factor.
Indications for Use
Indicated for general infusion use in patients requiring intravenous, percutaneous, subcutaneous, intra-arterial, epidural, or intra-operative (soft tissue/body cavity) delivery of fluids or medications, including local anesthetics for regional anesthesia and pain management (pre-operative, perioperative, postoperative). Includes patient-controlled bolus delivery.
Regulatory Classification
Identification
An infusion pump is a device used in a health care facility to pump fluids into a patient in a controlled manner. The device may use a piston pump, a roller pump, or a peristaltic pump and may be powered electrically or mechanically. The device may also operate using a constant force to propel the fluid through a narrow tube which determines the flow rate. The device may include means to detect a fault condition, such as air in, or blockage of, the infusion line and to activate an alarm.
Predicate Devices
I-Flow Homepump (Eclipse) C-Series
Baxter Infusor
Baxter Intermate
McKinley Accufuser
B Braun spring pump (used in Sgarlato pain kit)
Reference Devices
I-Flow PainBuster kit
On-Q pain management kit
Sgarlato PCIP
Submission Summary (Full Text)
{0}------------------------------------------------
AUG 2 6 2004
K041585
## SUMMARY OF SAFETY AND EFFECTIVENESS
June 1, 2004
Trade Name: AutoFuser Elastomeric Infusion Pump
Common Name: Elastomeric Infusion Pump
Classification Name: Pump, Infusion, Elastomeric
Classification Panel: General Hospital and Personal Use Device
All questions and/or comments concerning this document should be made to:
Robert J. Bard, Esq. Managing Director
HealthCare Technologies Consultants 150 Lake Village Dr Suite 203 Telephone: 949.235.0545 Fax: 949.240.3460
{1}------------------------------------------------
#### DESCRIPTION OF THE AUTOFUSER PRODUCT 1.0
- The AutoFuser pump (Continuous type Silicone Balloon) 1.1
- 1.1.1 The pump provides continuous fluid delivery with attached, fixed rate administration set.
- The pumps are supplied as fixed flow rates. 1.1.2
- 1.1.3 A silicone balloon is used as both the fluid reservoir of the device and the pressure (energy) source.
- The AutoFuser pump family includes models of the standard 1.2 AutoFuser with the addition of a Patient Medication Control Module (PCM)
- Patient Medication Control Module allows the patient to 1.2.1 administer a bolus of fixed volume with a fixed lockout (re-fill) time.
- 1.2.2 The pump is a disposable device intended for single patient use.
- 1.2.3 The pump is suitable for use as an ambulatory device and is intended for use in the hospital, home environment or alternative care sites.
- 1.2.4 The AutoFuser and the AutoFuser PCM pumps are substantially similar to the I-Flow Homepump (Eclipse) C-Series (included in the I-Flow PainBuster kit and the On-Q pain management kit), the Baxter Infuser and Intermate, the McKinley Accufuser, and the B Braun spring pump (used in the Sgarlato pain kit).
### THE AUTOFUSER/AUTOFUSER PCM PUMP AND ITS PREDICATE 2.0 DEVICES ARE INTENDED:
- For general infusion use. Routes of infusion include intravenous, 2.1 percutaneous, subcutaneous, intra-arterial and epidural and into the intra-operative (soft tissue / body cavity) site.
- 2.2 General infusion use Includes pain management for pre-operative, perioperative and postoperative surgery.
- The predicate pumps (and the pumps included with the I-2.2.1 Flow PainBuster and ON-Q Infusion Kit and the Sgarlato Pain Control Infusion Pump (PCIP)) have the same intended use as the device under review:
{2}------------------------------------------------
- 2.2.2 The AutoFuser family of ambulatory infusion pumps with integrated administration set, either separately or as part of a convenience kit, and its predicate devices are indicated for general infusion use. Routes of infusion include intravenous. percutaneous, subcutaneous, inter-arterial and epidural, and into intra-operative (soft tissue / body cavity) sites.
Members of the AutoFuser family and the predicate devices are also intended for patient-controlled infusion using the integrated bolus button.
General infusion uses include continuous infusion of a local anesthetic near a nerve for regional anesthesia and pain management for pre-operative, perioperative and postoperative surgery.
- 2.3 Device Descriptions
- 2.3.1 Specifications
- 2.3.1.1 The AutoFuser and the AutoFuser PCM pumps have fill volumes and flow rates substantially similar to the pumps of the McKinley Medical Accufuser, the I-Flow PainBuster (Homepump Eclipse C-Series), the B Braun spring pump included in the Sgarlato PCIP, and the Baxter Infusor and Intermate pumps.
- 2.3.2 Flow Control
- The AutoFuser and AutoFuser PCM pumps and 2.3.2.1 the identified predicate device use either a glass orifice or PVC tubing to control the flow rate.
- 2.3.3 Materials
- 2.3.3.1 All fluid path materials of the AutoFuser pumps are in conformance with ISO 10993 Part 1.
{3}------------------------------------------------
Image /page/3/Picture/1 description: The image is a black and white seal for the Department of Health & Human Services - USA. The seal is circular with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" around the perimeter. In the center of the seal is a stylized image of a bird.
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
### AUG 2 6 2004
ALGOS, LC C/O Mr. Robert J. Bard Managing Director Healthcare Technologies Consultants 150 Lake Village Drive, Suite 203 Ann Arbor, Michigan 48103
Re: K041585
Trade/Device Name: AutoFuser Infusion Pump Regulation Number: 880.5725 Regulation Name: Infusion Pump Regulatory Class: II Product Code: MEB Dated: June 1, 2004 Received: June 14, 2004
Dear Mr. Bard:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
{4}------------------------------------------------
Page 2 - Mr. Bard
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements nfour that or any Federal statutes and regulations administered by other Federal agencies. or not ret of any ly with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice and fishing (21 CF CF th in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), 11 yea contact the Office of Compliance at (301) 594-4618. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html
Sincerely yours,
Chiu Lin, Ph.D.
Director Division of Anesthesiology, General Hospital, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{5}------------------------------------------------
# Indications for Use
510(k) Number (if known): K041585
AutoFuser infusion pump Device Name:
Indications For Use:
The AutoFuser family of ambulatory infusion pumps with integrated administration set, The AutoFuser family of ambulatory intrason paniped for general infusion use.
either separately or as part of a convenience subentageous inter-arterial an either separately of as part of a convenience in the rubert of the readers, inter-arterial and
Routes of infusion include intravenous, percutaneous, subout announces in the Routes of infusion intra-operative (soft tissue / body cavity) sites.
Within the AutoFuser family are pump models intended for patient-controlled infusion using the integrated bolus button.
General infusion uses include continuous infusion of a local anesthetic near a nerve for
e General music uses infolude contined of the pre-operative, perioperative and postoperative surgery.
Prescription Use
(Part 21 CFR 801 Subpart D)
AND/OR
Over-The-Counter Use _ (21 CFF 801 Subpart C)
(PLFASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED
Concurrence of CDRH, Office of Device Evaluation (ODE)
Cluif
nesthesiology, General Hospitali Infection Cor trol, Dental
Page 1 of 1
510(k) Number: K041595
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.