SURGASSIST STRAIGHT LINEAR 4 ROW NO KNIFE DLUS WITH RELOADS

K040398 · Power Medical Interventions, Inc. · GDW · Mar 24, 2004 · General, Plastic Surgery

Device Facts

Record IDK040398
Device NameSURGASSIST STRAIGHT LINEAR 4 ROW NO KNIFE DLUS WITH RELOADS
ApplicantPower Medical Interventions, Inc.
Product CodeGDW · General, Plastic Surgery
Decision DateMar 24, 2004
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 878.4750
Device ClassClass 2
AttributesTherapeutic

Indications for Use

The SurgASSIST® Straight Linear 4 Row No Knife Digital Loading Units® with Reloads have applications for general and endoscopic surgery in gastrointestinal, gynecological, general abdominal and thoracic surgical procedures for resection, transection, creation of anastomoses, for open occlusion of the heart's left atrial appendage.

Device Story

Device consists of reloadable, single-patient-use Straight Linear 4 Row No Knife Digital Loading Units (DLUs) designed for tissue closure. Input: manual operation by surgeon during general or endoscopic surgery. Transformation: device applies two double-staggered rows of titanium staples to tissue; staples are formed to a controlled closed condition to secure tissue layers. Output: mechanically secured tissue via implanted staples. Used in OR settings for gastrointestinal, gynecological, abdominal, thoracic procedures, and open occlusion of the left atrial appendage. Benefits: provides secure tissue closure for various surgical openings.

Clinical Evidence

No clinical data provided; substantial equivalence is based on identical technological characteristics and design to the predicate device.

Technological Characteristics

Reloadable linear stapler; titanium staples; 4-row configuration; no-knife design; single-patient-use; mechanical actuation.

Indications for Use

Indicated for patients undergoing general, endoscopic, gastrointestinal, gynecological, abdominal, or thoracic surgical procedures requiring resection, transection, or anastomosis, and for patients requiring open occlusion of the heart's left atrial appendage.

Regulatory Classification

Identification

An implantable staple is a staple-like device intended to connect internal tissues to aid healing. It is not absorbable.

Predicate Devices

Submission Summary (Full Text)

{0}------------------------------------------------ K040398 Pi/2 # Section E ## MAR 2 4 2004 ### Traditional 510(k) - Summary In Accordance with 21 CFR Section 807.92 Power Medical Interventions, Inc., is submitting the following 510(k) Summary: 1) Submitter Information: Power Medical Interventions, Inc. 110 Union Square Drive New Hope, PA 18938 267-775-8151 Ph 267-775-8123 Fax Applicant: Barbara J. Whitman February 13, 2004 Date of Notification: - 2) Name of Device: | Trade Name: | SurgASSIST®<br>Straight Linear 4 Row No Knife DLUs<br>with Reloads | |-------------------------|--------------------------------------------------------------------| | Common Name: | Linear Staplers with Implantable Staples<br>and Reloads | | Classification<br>Name: | Staple, Implantable, GDW | - 3) Predicate Devices: - a. SurgASSIST® Straight Linear Stapler Digital Loading Units® with Reloads and Straight Linear 4 Row No Knife Digital Loading Units® with Reloads, Power Medical Interventions, Inc., New Hope, PA. REF SLS55B, SLSR55B, SLS55G, SLSR55G, SLS55B4 and SLSR55B4 (K030653). {1}------------------------------------------------ #### 4) Device Description: The devices described here are reloadable Straight Linear 4 Row No Knife Digital Loading Units® (DLUs) with Reloads for single patient use. The SLS55B4 DLUs are designed to place two, double-staggered rows of titanium staples in various types of tissues. The SLS55B4 DLUs are used to close otomies and other common and uncommon openings by applying staples through the tissue and forming the staples to a controlled closed condition to secure the layers of tissue together. - 5) Device Modification The Straight Linear 4 Row No Knife Digital Loading Units® are identical to the predicate devices (K030653). The only changes are in the "Indications For Use" statement. The specific change is to include the application of the device for open occlusion of the heart's left atrial appendage. - 6) Indications For Use The SurgASSIST® Straight Linear 4 Row No Knife Digital Loading Units® with Reloads have applications for general and endoscopic surgery in gastrointestinal, gynecological, general abdominal and thoracic surgical procedures for resection, transection, creation of anastomoses, for open occlusion of the heart's left atrial appendage. - 7) Comparison to Predicate Devices The Straight Linear 4 Row No Knife Digital Loading Units® with Reloads are identical to the previously cleared predicate Straight Linear 4 Row No Knife Digital Loading Units® with Reloads (K030653). We have expanded the Indications For Use, but the fundamental scientific technology is identical. Please refer to Section J for predicate comparison chart. {2}------------------------------------------------ Image /page/2/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a circular seal with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" around the perimeter. Inside the circle is a stylized symbol resembling three curved lines, possibly representing a stylized bird or a flame. Public Health Service Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 MAR 2 4, 2004 Ms. Barbara Whitman Regulatory Affairs Manager Power Medical Interventions, Inc. 110 Union Square Drive New Hope, Pennsylvania 18938-1364 Re: K040398 Trade/Device Name: SurgASSIST® Straight Linear 4 Row No Knife Digital Loading Units® with Reloads Regulation Number: 21 CFR 878.4750 Regulation Name: Implantable staple Regulatory Class: II Product Code: GDW Dated: February 13, 2004 Received: February 17, 2004 Dear Ms. Whitman: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. {3}------------------------------------------------ Page 2 - Ms. Barbara Whitman This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at (301) 594-4659. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html Sincerely yours, Miriam C. Provost for Celia M. Witten, Ph.D., M.D. Director Division of General, Restorative and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {4}------------------------------------------------ K04032f Power Medical Intervantions. Inc. SurgASSIST® Straight Linear 4 Row No Knife DLUs with Reloads Traditional 510(k) – Expanded Indications • February 13, 2004 #### Section D #### Indications for Use Power Medical Interventions, Inc. New Hope, PA 18938 510(k) Number (if known): Device Name: SurgASSIST® Straight Linear 4 Row No Knife Digital Loading Units® with Reloads Indications For Use: The SurgASSIST® Straight Linear 4 Row No Knife Digital Loading Units® with Reloads have applications for general and endoscopic surgery in gastrointestinal, gynecological, general abdominal and thoracic surgical procedures tor resection, transection, creation of anastomases, for open occlusion of the heart's left atrial appendage. Prescription Use _____________________________________________________________________________________________________________________________________________________________ Over-The-Counter Use (Part 21 CFR 801 Subpart D) (21 CFR 807 Subpart C) (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED) AND/OR Concurrence of CDRH, Office of Device Evaluation (ODE) Page 1 of 1 Muriam C. Lawrent (Division Sign-Off) Division of General, Restorative, and Neurological Devices **510(k) Number** K040398
Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...