K033840 · CellaVision AB · JOY · Feb 10, 2004 · Hematology
Device Facts
Record ID
K033840
Device Name
CELLAVISION DM96 AUTOMATIC HEMATOLOGY ANALYZER
Applicant
CellaVision AB
Product Code
JOY · Hematology
Decision Date
Feb 10, 2004
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 864.5260
Device Class
Class 2
Attributes
AI/ML
AI Performance
Output
Algorithm
Acceptance
Observed
Dev DS
Dev Readers
Test DS
Test Readers
White blood cell differential count
Deterministic artificial neural networks
—
—
—
—
Clinical evaluation performed according to NCCLS document H-20A
—
Indications for Use
DM96 is an automated cell-locating device. DM96 automatically locates and presents images of blood cells on peripheral blood smears. The operator identifies and verifies the suggested classification of each cell according to type. DM96 is intended to be used by skilled operators, trained in the use of the device and in recognition of blood cells.
Device Story
DM96 is an automated hematology analyzer for peripheral blood smears. System includes slide feeder, microscope, camera, and computer with CellaVision Blood Differential software. Device scans stained glass slides to locate white blood cells, stores digital images, and presents them to the operator. Software uses deterministic artificial neural networks (ANNs) to pre-classify cells. Operator reviews images on a display to verify, accept, or modify suggested classifications. Device also provides overview images for red blood cell morphology characterization and platelet estimation. Used in clinical settings by trained laboratory personnel. Output aids in differential count procedures, improving efficiency and standardization of cell identification compared to manual microscopy.
Clinical Evidence
Clinical evaluation performed per NCCLS H-20A protocol. Study assessed accuracy for cell-location, accuracy and precision of verified cell classification, and clinical sensitivity/specificity. Results demonstrated equivalence to the DiffMaster Octavia™ predicate method.
Technological Characteristics
Automated cell-locating device; includes slide feeder, microscope, and camera. Analyzes Romanowsky-stained peripheral blood smears. Uses deterministic artificial neural networks (ANNs) for image classification. System is computer-based with proprietary acquisition and classification software. Class II device (21 CFR 864.5260).
Indications for Use
Indicated for automated location and presentation of blood cell images on peripheral blood smears to assist skilled, trained operators in performing differential counts, red blood cell morphology characterization, and platelet estimation.
Regulatory Classification
Identification
An automated cell-locating device is a device used to locate blood cells on a peripheral blood smear, allowing the operator to identify and classify each cell according to type. (Peripheral blood is blood circulating in one of the body's extremities, such as the arm.)
{1}------------------------------------------------
# Section 2. SUMMARY AND CERTIFICATION
# 2.1. 510 (k) Summary
#### 2.1.1. Summary of Safety and Effectiveness
In accordance with 21 CFR 807.92, the following information constitutes the 510(k) summary for DM96.
| SUBMITTER'S NAME: | CellaVision AB |
|---------------------|---------------------------------------------|
| ADDRESS: | Ideon Research Park, SE-223 70 Lund, Sweden |
| CONTACT PERSON: | Constance G. Bundy |
| TELEPHONE NUMBER: | 763-574-1976 |
| FAX NUMBER: | 763-571-2437 |
| DATE OF SUBMISSION: | December 9, 2003 |
#### 1. Identification of device
Proprietary Name: CellaVision DM96 Automatic Hematology Analyzer Common Name: DM96 Classification Status: Class II per regulations 21CFR 864.5260 Product Codes: JOY
#### 2. Equivalent devices
CellaVision AB believes DM96 is substantially equivalent to the Romanowsky stain manual light microscopic process for cell classification (21CFR 864.3600 Class I exempted from premarket notification procedure) and DiffMaster Octavia™ Hematology Analyzer, 510(k) number K003301, CellaVision AB.
#### 3. Description of the device
DM96 is an automated cell-locating device for differential count of white blood cells, characterization of red blood cell morphology and platelet estimation. DM96 consists of a slidescanning unit (a slide feeder, a microscope and a camera) and a computer system containing the acquisition and classification software "CellaVision Blood Differential software".
#### 4. Intended use
DM96 is an automated cell-locating device.
DM96 automatically locates and presents images of blood cells on peripheral blood smears. The operator identifies and verifies the suggested classification of each cell according to type.
DM96 is intended to be used by skilled operators, trained in the use of the device and in recognition of blood cells.
{2}------------------------------------------------
#### 5. Technological characteristics, comparison to predicate device
Like the predicate device, DM96 locates white blood cells, stores digital images of the cells and displays the images in an organized manner and suggests a cell class for each cell to aid operators in performing the differential count procedure. A competent operator is required to confirm or modify the suggested classification of each cell. It is intended to be used by skilled operators, trained in the use of the device and in recognition of blood cells. Like the predicate device, DM96 presents an overview image from which it is possible to characterize red blood cells regarding size, shape and color. In addition, the DM96 presents an overview image and facilitates platelet estimation.
Brief discussion of non-clinical factors supporting a determination of substantial equivalence: The method requires a competent human examiner to review the microscopic images of the cells as does the predicate method and device. See substantial equivalence comparisons below.
Brief discussion of clinical tests supporting a determination of substantial equivalence: A clinical evaluation has been performed to confirm equivalence with the predicate method DiffMaster Octavia™ for differentiation of white blood cells. The study has been performed according to a predefined protocol based upon the approved standard, NCCLS, vol. 23, no 1, document H-20A. March 1992: Reference Leukocyte Differential Count (proportional) and Evaluation of Instrumental Method. Complementary tests have been performed to confirm celllocation, precision and overview image quality.
#### Conclusions drawn from clinical tests:
The following information was obtained from the clinical tests:
- · accuracy for cell-location
- · accuracy for the verified classification for each cell class
- · precision for the verified classification for each cell class
- · clinical sensitivity and specificity
The results show that the DM96 is equivalent in accuracy, precision and clinical sensitivity and specificity and fulfilled the pre-defined requirements for overview image quality.
| Characteristic | Manual light<br>microscopic process | DiffMaster Octavia™ DM 96 | |
|-----------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Intended use | Manual method for<br>cell-location and<br>identification, for in-<br>vitro use.<br><br>Verification of results<br>by human operator. | Automated cell-<br>locating device for<br>cell-location, and<br>identification, for in-<br>vitro use.<br><br>Verification of results<br>by human operator. | Automated cell-<br>locating device for<br>cell-location, and<br>identification, for in-<br>vitro use.<br><br>Verification of results<br>by human operator. |
| Sample type | Stained blood film on<br>glass slides of<br>peripheral whole<br>blood. | Stained blood film on<br>glass slides of<br>peripheral whole<br>blood. | Stained blood film on<br>glass slides of<br>peripheral whole<br>blood. |
| Characteristic | Manual light<br>microscopic process | DiffMaster Octavia™ | DM 96 |
| Sample<br>preparation | Romanowsky stain | Romanowsky stain | Romanowsky stain |
| Analysis<br>technique | White blood cells:<br>The examiners usually<br>locate/count white<br>blood cells by moving<br>according to the<br>battlement track<br>pattern on the smear<br>and distinguish<br>between classes of<br>white blood cells. | White blood cells:<br>Cells are<br>located/counted by<br>moving according to<br>the battlement track<br>pattern. Cell images<br>are analyzed using<br>standard mathematical<br>methods, including<br>deterministic artificial<br>neural networks<br>(ANN's) trained to<br>distinguish between<br>classes of white blood<br>cells.<br>The cell images are<br>pre-classified and the<br>operator verifies the<br>suggested<br>classification by<br>accepting or<br>reclassifying. | White blood cells:<br>Cells are<br>located/counted by<br>moving according to<br>the battlement track<br>pattern. Cell images<br>are analyzed using<br>standard mathematical<br>methods, including<br>deterministic artificial<br>neural networks<br>(ANN's) trained to<br>distinguish between<br>classes of white blood<br>cells.<br>The cell images are<br>pre-classified and the<br>operator verifies the<br>suggested<br>classification by<br>accepting or<br>reclassifying. |
| | Red blood cells:<br>The examiners<br>characterize red blood<br>cell morphology from<br>an overview. | Red blood cells:<br>The device presents an<br>overview image.<br>The examiners<br>characterize red blood<br>cell morphology from<br>the image. | Red blood cells:<br>The device presents an<br>overview image.<br>The examiners<br>characterize red blood<br>cell morphology from<br>the image. |
| | Platelets:<br>The examiners<br>manually count and<br>estimate the platelet<br>concentration from an<br>overview according to<br>a standardized<br>procedure (21 CFR<br>864.6160 Manual<br>blood cell counting<br>device, Class I). | | Platelets:<br>The device presents an<br>overview image.<br>The examiners<br>manually count and<br>estimate the platelet<br>concentration from the<br>overview image<br>according to a<br>standardized<br>procedure. |
#### Comparative features of DM96 compared with the predicate devices:
{3}------------------------------------------------
:
·
{4}------------------------------------------------
# 6. Discussion of Performance Testing.
An extensive collection of tests has been conducted and successfully completed, including tests to ensure safety, effectiveness, and compliance with product requirements.
The following tests were conducted and successfully completed:
a) Evaluation of:
- Performance (accuracy and precision, clinical sensitivity, specificity, cell-location)
- Safety
b) Inspections to verify that all design features are as intended and that all authorized design changes have been accomplished and recorded.
c) Validation of the system (including efficacy of user interface)
### 7. Conclusion
Based on extensive performance testing and a comparison to the predicate device, it is the conclusion of CellaVision AB that DM96 is substantially equivalent to devices already on the market (cleared by the 510(k) process) and presents no new concerns about safety and effectiveness.
{5}------------------------------------------------
#### DEPARTMENT OF HEALTH & HUMAN SERVICES
Image /page/4/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a stylized eagle with three stripes forming its body and wings. The eagle is facing right. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES USA" is arranged in a circular pattern around the eagle.
Public Health Service
Food and Drug Administratio 2098 Gaither Road Rockville MD 20850
FEB 1 0 2004
CellaVision AB c/o Ms. Constance G. Bundy C. G. Bundy Associates, Inc. 6740 Riverview Terrace Minneapolis, MN 55432
Re: k033840
> Trade/Device Name: CellaVision DM96 Regulation Number: 21 CFR 864.5260 Regulation Name: Automated cell-locating device Regulatory Class: Class II Product Code: JOY: GKZ Dated: December 9, 2003 Received: December 10, 2003
Dear Ms. Bundy:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food. Drug. and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adultcration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in Title 21, Code of Federal Regulations (CFR), Parts 800 to 895. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Parts 801 and 809); and good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820).
{6}------------------------------------------------
#### Page 2
This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific information about the application of labeling requirements to your device, or questions on the promotion and advertising of your device, please contact the Office of In Vitro Diagnostic Device Evaluation and Safety at (301) 594-3084. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html.
Sincerely yours.
Aven Antman, m.D.
Steven I. Gutman, M.D., M.B.A. Director Office of In Vitro Diagnostic Device Evaluation and Safety Center for Devices and Radiological Health
Enclosure
{7}------------------------------------------------
# 1.2. Indications for Use
510(k) Number_ K 033840
Device Name: CellaVision DM96
#### Indications for Use:
DM96 is an automated cell-locating device.
DM96 automatically locates and presents images of blood cells on peripheral blood smears. The operator identifies and verifies the suggested classification of each cell according to type.
DM96 is intended to be used by skilled operators, trained in the use of the device and in recognition of blood cells.
(Please do not write below this line - continue on another page if needed)
Concurrence of CDRH, Office of Device Evaluation (ODE)
OR
Prescription Use ﺳ (Per 21 CFR 801.109)
Over the Counter Use_ ________________________________________________________________________________________________________________________________________________________
Maria Chen for Joseph Bautista
**Division Sign-Off**
Office of In Vitro Diagnostic Device Evaluation and Safety
510(k) K 053840
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Guidance alerts
New and changed FDA guidance documents, emailed as a daily digest.
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the ? button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only Software as a Medical Device, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (Software as a Medical Device), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.