← Product Code [FAD](/productcode/FAD) · K033210

# BIOTEQ DOUBLE PIGTAIL URETERAL STENT SET (K033210)

_Bioteque Corp. · FAD · Dec 30, 2004 · Gastroenterology, Urology · SESE_

**Canonical URL:** https://fda.innolitics.com/device/K033210

## Device Facts

- **Applicant:** Bioteque Corp.
- **Product Code:** [FAD](/productcode/FAD.md)
- **Decision Date:** Dec 30, 2004
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 876.4620
- **Device Class:** Class 2
- **Review Panel:** Gastroenterology, Urology
- **Attributes:** Therapeutic

## Indications for Use

BIOTEQ® DOUBLE PIGTAIL URETERAL STENT SET is intended to facilitate the temporary internal drainage of urine from the kidney to the bladder via placement endoscopically by a trained physician.

## Device Story

Device is a radiopaque, double-pigtail ureteral stent set used for temporary internal drainage of urine from kidney to bladder. Set includes ureteral stent with drainage holes, centimeter graduations, and positioning line; pusher catheter (introducer sheath); guide wire (spiral stylet) with PTFE-coated stainless steel; and plastic clips. Used in clinical settings by trained physicians via endoscopic placement. Stent facilitates urine flow; benefits patient by relieving obstruction or maintaining patency during healing. No complex electronics or software involved.

## Clinical Evidence

Bench testing only. Device conforms to ISO 10993 series (biocompatibility), ISO 11607-1, ISO 11135, and USP pyrogenic standards.

## Technological Characteristics

Radiopaque ureteral stent; stainless steel guide wire with PTFE coating; pusher catheter. Conforms to ISO 10993, ISO 11607-1, ISO 11135, and USP standards. Mechanical device; no software or energy source.

## Regulatory Identification

A ureteral stent is a tube-like implanted device that is inserted into the ureter to provide ureteral rigidity and allow the passage of urine. The device may have finger-like protrusions or hooked ends to keep the tube in place. It is used in the treatment of ureteral injuries and ureteral obstruction.

## Predicate Devices

- Rusch Ureter Stent Integral Set and Rusch Ureter DD Stent Sets ([K982974](/device/K982974.md))

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

DEC 3 0 2004

# 510(K) SUMMARY

Image /page/0/Picture/2 description: The image shows the text "K033210" in a handwritten style. The text is slightly slanted and has a somewhat rough appearance. There is some additional illegible text below the main text, which appears to be handwritten as well. The background is plain white.

" " is summary of 510(k) safety and effectiveness information is being submitted in accordance with
the requirements of SMDA and 21 CFR \$807.92

| 1. | Submitter's Name:    | BIOTEQUE CORPORATION                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                           |
|----|----------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
|    | Address:             | 8 F-3, No. 136, Sec.3,Jen-Ai Road, Taipei, Taiwan, R.O.C.                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                      |
|    | Phone:               | 886-2-2708-3188                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                |
|    | Fax:                 | 886-2-2707-6610                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                |
|    | Contact:             | Mr. William Lee (General Manager)                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                              |
| 2. | Device Name          |                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                |
|    | Trade Name:          | BIOTEQ® DOUBLE PIGTAIL URETERAL STENT SET, or<br>BIOTEQ® URETERAL STENT SET(Double J Type)                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                     |
|    | Common Name:         | Ureteral Stent                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                 |
|    | Classification name: | Ureteral Stent                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                 |
| 3. | Classification:      | Class II                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                       |
|    | Predicate Device:    | Rusch Ureter Stent Integral Set and Rusch Ureter DD Stent Sets<br>(K982974) marketed by RUSCH INTL.                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                            |
| 5. | Device Description:  | The BIOTEQ® DOUBLE PIGTAIL URETERAL STENT SET consist of<br>a ureter stent that is completely radiopaque, coiled cylindrical or open<br>tip with drainage holes at intervals of 5-20 mm, centimeter<br>graduations, continuous black positioning line to indicate the direction<br>in which the catheter tip coils, and black marking at the catheter end.<br>The Pusher Catheter (Introducer sheath) is approximately 45cm long.<br>The Guide Wire (Spiral stylet) is made of stainless steel with PTFE<br>coating and a flexible safety tip and a marked rigid tip and is<br>approximately 120 cm long. The plastic dispenser is used to protect<br>the Guide Wire (Spiral stylet). There are also plastic clips in the set. |
| 6. | Intended Use:        | INDICATION FOR USE<br>BIOTEQ® DOUBLE PIGTAIL URETERAL STENT SET is intended to<br>facilitate the temporary internal drainage of urine from the kidney to<br>the bladder via placement endoscopically by a trained physician.                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                   |

{1}------------------------------------------------

- In terms of Physical specification, Chemical specification 7. Performance Summary: specification & Sterilization Specification, the device conforms to applicable standards included ISO 10993 series, ISO 11607-1, ISO 11135, USP Pyrogenic standards & related standards-----etc.
#### Conclusions: 8.

The BIOTEQ® DOUBLE PIGTAIL URETERAL STENT SET have the same intended use and similar technological characteristics as the Rusch Ureter Stent Integral Set and Rusch Ureter DD Stent Sets (K982974) marketed by RUSCH INTL.. Moreover, bench testing contained in this submission demonstrate that any differences in their technological characteristics do not raise any new questions of safety or effectiveness. Thus, the BIOTEQ® DOUBLE PIGTAIL URETERAL STENT SET is substantially equivalent to the predicate devices.

{2}------------------------------------------------

Image /page/2/Picture/1 description: The image shows the seal of the Department of Health & Human Services - USA. The seal is circular and contains the words "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" around the top half of the circle. In the center of the seal is an abstract image of an eagle.

#### Public Health Service

Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850

## DEC 3 0 2004

Bioteque Corporation c/o Ms. Jennifer Reich 3892 South America West Trail FLAGGSTAFF, AZ 86001

RE: K033210

Trade/Device Name: Bioteq Double Pigtail Ureteral Stent Set Regulation Number: 21 CFR§876.4620 Regulation Name: Ureteral Stent Regulatory Class: II Product Code: 78 FAD Dated: December 13, 2004 Received: December 16, 2004

Dear Ms. Reich:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (sections 531-542 of the Act); 21 CFR 1000-1050.

{3}------------------------------------------------

This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at one of the following numbers, based on the regulation number at the top of this letter:

| 8xx.1xxx                         | (301) 594-4591 |
|----------------------------------|----------------|
| 876.2xxx, 3xxx, 4xxx, 5xxx       | (301) 594-4616 |
| 884.2xxx, 3xxx, 4xxx, 5xxx, 6xxx | (301) 594-4616 |
| 892.2xxx, 3xxx, 4xxx, 5xxx       | (301) 594-4654 |
| Other                            | (301) 594-4692 |

Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsmamain.html.

Sincerely yours,

Nancy C. Brogdon

Nancy C. Brogdon Director, Division of Reproductive, Abdominal, and Radiological Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{4}------------------------------------------------

## Indications for Use

510(k) Number (if known): ____________________________________________________________________________________________________________________________________________________

Device Name: BIOTEQ® DOUBLE PIGTAIL URETERAL STENT SET BIOTEQUE CORPORATION

### INDICATIONS FOR USE:

BIOTEQ® DOUBLE PIGTAIL URETERAL STENT SET is intended to facilitate the temporary internal drainage of urine from the kidney to the bladder via placement endoscopically by a trained physician.

Nancy C hogdon

Division of Reproductive, Abdominal,
and Radiological Devices
510(k) Number K0 332/0

Prescription Use _____________________________________________________________________________________________________________________________________________________________ (Part 21 CFR 801 Subpart D) AND/OR

Over-The-Counter Use _ (21 CFR 807 Subpart C)

(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)

Concurrence of CDRH, Office of Device Evaluation (ODE)

See above.
Wbrogdon

Page 1 of 1

---

**Source:** [https://fda.innolitics.com/device/K033210](https://fda.innolitics.com/device/K033210)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
