K032919 · C.T.M. Homecare Product, Inc. · INI · Oct 15, 2003 · Physical Medicine
Device Facts
Record ID
K032919
Device Name
C.T.M. MOBILITY SCOOTER, MODEL HS-250
Applicant
C.T.M. Homecare Product, Inc.
Product Code
INI · Physical Medicine
Decision Date
Oct 15, 2003
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 890.3800
Device Class
Class 2
Indications for Use
The C.T.M. Mobility Scooter HS-250 is an indoor/outdoor scooter that provides transportation for a disabled or elderly person.
Device Story
The C.T.M. Mobility Scooter HS-250 is a battery-operated, four-wheeled electric scooter for indoor/outdoor use. The rider operates the device via hand-controlled thumb levers on the steering column, which regulate speed and direction (forward/reverse). The device features an automatic electric braking system that engages when levers are released or if power fails. It includes an onboard 24-volt battery charger, adjustable seat, and armrests. The scooter can be disassembled into four components for transport without tools. A PG Drives Technology S-drive controller manages motor output and includes self-diagnostic capabilities indicated by a flashing warning light. The device provides mobility for the user, who is also the operator. It is intended for personal use by disabled or elderly individuals to navigate indoor and outdoor environments.
Clinical Evidence
No clinical data or comparative performance testing was submitted. Substantial equivalence is based on design, intended use, and adherence to established guidance for motorized mobility devices.
Technological Characteristics
Four-wheeled electric scooter; 250W, 3800 rpm motor; two 12V 12Ah batteries; PG Drives Technology S-drive controller; automatic electric braking system; onboard 24V constant current charger; 7-inch front/8-inch rear wheels; max forward speed 4.1 mph; max reverse speed 1.5 mph; disassembly into four components; self-diagnostic warning system.
Indications for Use
Indicated for disabled or elderly persons requiring indoor/outdoor transportation assistance.
Regulatory Classification
Identification
A motorized three-wheeled vehicle is a gasoline-fueled or battery-powered device intended for medical purposes that is used for outside transportation by disabled persons.
{1}------------------------------------------------
OCT 1 5 2003
K032919
1055
# 510(k) SUMMARY
C.T.M. Homecare Product, Inc. Submitter's Name: 1663 Iowa Ave. Riverside, CA 92507 909-788-8168
Date summary prepared:
September 10, 2003
Device name:
Proprietary name: Common or usual name: Classification name:
C.T.M. Mobility Scooter HS-250 Electric scooter. Motorized three-wheeled vehicle, Class II, 21 CFR 890.3800.
Legally marketed device for substantial equivalence comparison:
C.T.M. Mobility Scooter HS-360 submitted by Warepalmy Enterprise LLC (USA) and cleared for marketing under 510(k) *K031272.
Description of the device:
The C.T.M. Mobility Scooter HS-250 is an indoor/outdoor electric scooter that is battery operated. It has a base with four wheels with a lightweight seat, armrests, and a front basket. The movement of the scooter is controlled by the rider who uses hand controls located at the top of the steering column. The device can be disassembled for transport and is provided with an onboard battery charger.
Intended use of device:
The device is an indoor/outdoor scooter that provides transportation for a disabled or elderly person.
Technological characteristics:
The device features and use parameters of the HS-250 and the HS-360 are very similar. Both are electric scooters that are battery operated and have automatic braking systems. Batteries and battery chargers are provided with each scooter. Use parameters are very similar, varying only slightly with selected parameters, such as the travel range and the grade the scooter can climb.
Testing conducted:
Tests listed in the Guidance Document for the Preparation of Premarket Notification [510(k)] Applications for Mechanical and Powered Wheelchairs, and Motorized Three Wheeled Vehicles, July 1995, were conducted and the results included in the subject 510(k) submission.
### Performance testing:
Comparative performance testing and clinical evaluations were not submitted as part of this 510(k).
{2}------------------------------------------------
K032919
2 of 5
# SECTION 3 - INTENDED USE
Intended use of device:
The C.T.M. Mobility Scooter HS-250 is an indoor/outdoor scooter that provides transportation for a disabled or elderly person.
Intended use of predicate device:
The C.T.M. Mobility Scooter HS-360 is an indoor/outdoor scooter that provides transportation for disabled or elderly persons.
Comparison:
The intended uses of the respective products are the same. Each provides increased mobility for one individual, who is also the operator. Each device can be used in indoor and outdoor settings.
The intended use of the C.T.M. Mobility Scooter HS-250 is given on page 1 of the Instruction Booklet as found in Appendix II of this submission. The intended use of the predicate model is given in the Indications for Use sheet from the 510(k), a copy of which can be found in Appendix III.
{3}------------------------------------------------
C.T.M. Mobility Scooter HS-250 510(k) Notification Page 6
K032919
30F5
## SECTION 4 - DEVICE INFORMATION
#### Executive Summary
The C.T.M. Mobility Scooter HS-250 is an indoor/outdoor electric scooter that is battery operated. It has a base with four wheels with a lightweight seat, armrests, and front basket. The movement of the scooter is controlled by the rider who uses hand controls located at the top of the steering column. The device can be disassembled for transport and is provided with an onboard battery charger.
The C.T.M. Mobility Scooter HS-250 is a new device and is not a modification of a previously cleared device. Numerous electric scooters are currently on the market.
#### Scooter
The C.T.M. Mobility Scooter HS-250 is a four-wheeled, battery-powered electric scooter. The design of the scooter is quite similar to other electric scooters that are already on the market. The scooter has a sturdy base, which connects the reardrive wheels and the front casters. The base also contains the motor, provides spaces for the two batteries, and supports the seat. The seat has adjustable armrests and its height can be adjusted. In addition, the front and rear base pieces can be adjusted to allow more legroom. A controller with thumb control levers located at the top of the steering column enables the rider to control the movement of the scooter. The diagrams in Appendix I show the features and dimensions of the subject scooter. Diagram 1 is a representation of the C.T.M. Mobility Scooter HS-250 with the major parts labeled. Diagram 2 shows the HS-250 from different views with major dimensions given.
If desired, the scooter can be disassembled to provide easier transport. There are 4 components: the base unit with attached steering column, the battery pack, the seat, and the front basket. The front wheels are 7" in diameter and the rear wheels are 8" in diameter. The heaviest single component for model HS-250 weighs 27.7 pounds. With batteries, the scooter weighs approximately 107 pounds. Assembly of the scooter is simple and does not require any tools.
In the assembled scooter, the motor and batteries are located in the base unit. The controller is equipped with associated thumb control levers that enable the scooter to be operated with the hands. These controls are found on the top of the steering column. Handlebars protrude from either side of the steering column. These keep the hands in the correct position to operate the controls and to steer. There is a 250 watt, 3800 rpm motor in the base of the scooter. There is a circuit breaker in the electrical line that will trip if electrical circuits are overloaded. Circuit breaker activation usually denotes a temporary event. After a brief rest, the rider can push the circuit breaker and normal operation will usually be restored.
The braking system in the HS-250 model is electric and automatic. It is on the rear wheels only. The brakes are automatically "on" except when the scooter is turned on and the thumb levers are moved away from the neutral position. When
{4}------------------------------------------------
C.T.M. Mobility Scooter HS-250 510(k) Notification Page 7
K032919
40F5
the thumb levers are released or moved back to neutral, the brakes engage again. If the electrical brake system fails, the brakes will default to the closed or "brakes on" position, thereby stopping the scooter. The braking distance at maximum speed is 4.67 feet.
The C.T.M. Mobility Scooter HS-250 has a free-wheeling device located near the anti-tip wheels. The normal position of the lever is "D". In this position the electric scooter will not move without turning on the key and having charged batteries. Moving the lever to the position marked "N" allows the scooter to be rolled freely without the key being turned on. This feature is very useful when maneuvering the scooter for battery charging or storage. The scooter is not intended to be ridden at all in this free-wheeling mode.
The electric scooter is controlled by the rider using the hand controls, i.e., the thumb lever controls that are attached to the top of the steering column. The controller unit is a Model PG 45amp S-drive Controller from PG Drives Technology, Inc. This company used to be called Penny & Giles and has been developing controllers for scooters and powered wheelchairs for a number of years. It consists of a controller box, thumb levers, electrical cable, and imbedded software. When both the left and right thumb levers are in their central, neutral position, the scooter is stopped. If the right lever is engaged, the scooter moves forward. If the left lever is engaged, the scooter moves backward. When both left and right thumb levers are released, the levers automatically return to their central or neutral position, and movement of the scooter ceases. The actual speed at which the scooter moves in a forward or reverse direction depends on speed control dial setting and is proportional to the extent of displacement of the respective thumb lever. To turn the scooter, the steering column is moved in the direction of the desired turn. The minimum turning radius for model HS-250 is approximately 35.4 inches.
The battery charger is onboard in the base unit. Recharging the batteries occurs when the battery charger cable is plugged into both the battery charger and a standard electrical outlet. The scooter will not move unless the key is turned to ON and the batteries are charged.
On the control panel there are multiple controls. See Diagram 3 in Appendix I for locations. These controls include the on/off key, speed dial, battery level indicator, self diagnostic warning light, and horn button. The forward speed range is 0-4.1 mph. The reverse speed range is 0-1.5 mph. The speed dial is used to select an appropriate speed within each of these ranges. The speed dial has a rabbit at one end, indicating higher speed, with a turtle at the other end that represents lower speed. Turning the speed dial toward the turtle reduces the maximum speed within the speed range. Turning it toward the rabbit increases the maximum speed.
The battery level indicator, also called the battery gauge, shows the battery reserve. It consists of a series of yellow lights above three color ranges: red,
{5}------------------------------------------------
K032919
S0F5
yellow, and green. When the light is steady and lit in all three color ranges, the batteries are fully charged. When the light is steady, but lit only in the red and yellow zones, the batteries should be recharged as soon as possible,
Located next to the battery level indicator is a separate self-diagnostic warning light that flashes to indicate selected problems with the scooter. Generally speaking, the scooter cannot be driven when this light is flashing. The number of flashes helps determine the problem. The self-diagnostic signals are:
| Number of flashes | Problem |
|-------------------|--------------------------------------------|
| 1 | battery needs recharging |
| 2 | battery voltage too low to operate scooter |
| 3 | battery voltage too high |
| 4 | short in motor |
| 5 | brake malfunction |
| 6 | transmission lever not in neutral |
| 7 | transmission lever malfunction |
| 8 | motor problems |
| 9 | other internal errors |
Detailed explanations of these problems and solutions to them are given in the Troubleshooting section of the Instruction Booklet for the electric scooter, which can be found in Appendix II, beginning on page 31.
#### Batteries
The C.T.M. Mobility Scooter HS-250 runs on two 12-volt 12Ah batteries. These batteries are provided with the scooter. Replacements can be obtained from the distributor or other local sources.
### Battery Charger
A battery charger is onboard. It is a 24-volt constant current charger. It plugs into a standard 110 volt wall socket or into a 220 volt socket.
#### Accessories
There are no accessories for the C.T.M. Mobility Scooter HS-250.
### Regulatory Status
The C.T.M. Mobility Scooter HS-250 is a new device that has not been previously submitted to the FDA.
{6}------------------------------------------------
DEPARTMENT OF HEALTH & HUMAN SERVICES
Image /page/5/Picture/1 description: The image is a black and white logo for the U.S. Department of Health & Human Services. The logo features a stylized eagle with three horizontal lines representing its wings. The eagle is positioned within a circular border. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is written around the upper portion of the circular border.
#### Public Health Service
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
OCT 1 5 2003
C.T.M. Homecare Product, Inc. C/o Mr. Robert S. McQuate President R.S. McQuate & Associates, Inc. 3636 E. Columbine Drive Phoenix, AZ 85032
Re: K032919
Trade/Device Name: C.T.M. Mobility Scooter HS-250 Regulation Number: 21 CFR 890.3800 Regulation Name: Motorized three-wheeled vehicle Regulatory Class: II Product Code: INI September 12, 2003 Dated: Received: September 22, 2003
Dear Mr. McQuate:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration. Iisting of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (OS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
{7}------------------------------------------------
Page 2 - Mr. Robert S. McQuate
This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at (301) 594-4659. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html
Sincerely vours.
Sincerely yours,
for Mark n Milkinson
Celia M. Witten, Ph.D., M.D. Director Division of General, Restorative and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{8}------------------------------------------------
C.T.M. Mobility Scooter HS-250 510(k) Notification Page 3
### Indications for Use Statement
510(k) Number (if known):
Device name: C.T.M. Mobility Scooter HS-250
Indications for Use:
The C.T.M. Mobility Scooter HS-250 is an indoor/outdoor scooter that provides transportation for a disabled or elderly person.
(Please do not write below this line) ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Concurrence of CDRH, Office of Device Evaluation (ODE)
| Prescription Use<br>(Per 21 CFR 801.109) | OR | Over-The-Counter Use | ✓ |
|------------------------------------------|----|----------------------|---|
|------------------------------------------|----|----------------------|---|
*for*
(Division Sign-Off)
Division of General. Restorative
and Neurological Devices
K032919510(k) Number -
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Guidance alerts
New and changed FDA guidance documents, emailed as a daily digest.
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the ? button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only Software as a Medical Device, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (Software as a Medical Device), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.