DUNLEE FORMAT COLLIMATOR FAMILY

K031597 · Philips Medical Systems North America Co. · IZW · Jul 21, 2003 · Radiology

Device Facts

Record IDK031597
Device NameDUNLEE FORMAT COLLIMATOR FAMILY
ApplicantPhilips Medical Systems North America Co.
Product CodeIZW · Radiology
Decision DateJul 21, 2003
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 892.1610
Device ClassClass 2

Intended Use

The Dunlee "FORMAT" collimator family restricts the dimensions of the diagnostic X-rav field by limiting the size of the primary X-ray beam. The Dunlee manual "FORMAT M" collimators are intended for use in diagnostic X-ray systems during radiographic examinations. The Dunlee automatic "FORMAT A" collimators are intended for use in diagnostic X-ray systems during radiographic and fluoroscopic examinations.

Device Story

Dunlee FORMAT collimator family comprises manual and automatic beam-limiting devices for diagnostic X-ray systems. Manual versions provide direct shutter control at the collimator head; automatic versions interface with X-ray systems via ISO-CAN software. Functionality includes rectangular/circular field limitation, light field simulation, source-image distance measurement (mechanical/electronic), spectral/wedge filtering, and area exposure product dose measurement. Used in radiography, fluoroscopy, cardio, and vascular imaging environments. Operated by radiology staff to control radiation exposure area, ensuring patient safety by minimizing unnecessary X-ray exposure during diagnostic procedures.

Clinical Evidence

No clinical data. The device is a beam-limiting accessory for X-ray systems; substantial equivalence is based on technological characteristics and compliance with established performance and safety standards (21CFR1020.30-32, IEC 60601 series, UL 2601-1).

Technological Characteristics

Modular beam-limiting device for X-ray systems. Features include manual or automatic shutter control, light field simulation, spectral/wedge filtering, and dose measurement. Connectivity via ISO-CAN interface for automatic versions. Complies with IEC 60601-1, 60601-1-2, 60601-1-3, 60601-2-28, 60601-2-43, UL 2601-1, and CAN/CSA-C22.2 no. 601-1. Radiation performance per 21CFR1020.30-32.

Indications for Use

Indicated for use in diagnostic X-ray systems, including radiography, fluoroscopy, cardio, and vascular applications, to restrict the X-ray field dimensions by limiting the primary beam size.

Regulatory Classification

Identification

A diagnostic x-ray beam-limiting device is a device such as a collimator, a cone, or an aperture intended to restrict the dimensions of a diagnostic x-ray field by limiting the size of the primary x-ray beam.

Special Controls

*Classification.* Class II (special controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 892.9.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ **JUL 2 1 2003** Ko31597 # Philips Medical Systems ## 510(k) SUMMARY | Company name:<br>Address: | Philips Medical Systems North America Company<br>22100 Bothell Everett Highway<br>P.O. Box 3003<br>Bothell, WA 98041-3003, U.S.A. | |-----------------------------------|-----------------------------------------------------------------------------------------------------------------------------------| | Registration No.: | 1217116 | | Contact person:<br>Telephone No.: | Lynn Harmer<br>(425) 487-7312 | | Date prepared: | 2003-03-20 | | Device (trade) name: | Dunlee "FORMAT" collimator family | | Classification name: | Diagnostic X-ray Beam-Limiting Device (21CFR892.1610),<br>Class II (Procodes: 90 IZW & 90 IZX). | | Common/usual name: | Automatic resp. Manual Radiographic Collimator. | ### Predicate device: - The Dunlee manual "FORMAT M" collimators are substantially equivalent to the pre-. amendment manual collimators with codenumbers 9804 602 60501 and 9804 602 61501 (BRH accession number 7410693), manufactured by Philips Medical Systems. - The Dunlee automatic "FORMAT A" collimators are substantially equivalent to the NICOL . collimator family manufactured by Philips Medical Systems, which has been determined to be substantially equivalent to legally marketed predicate devices under number K990423. #### Device description: The Dunlee "FORMAT" collimator family is a family of Beam-Limiting Devices, which comprises both manual and automatic collimators. The manual collimators are to be used in diagnostic radiographic X-ray systems, and the automatic collimators are to be used in both diagnostic fluoroscopy X-ray systems and diagnostic radiographic X-ray systems. #### Intended use: - . The Dunlee "FORMAT" collimator family restricts the dimensions of the diagnostic X-rav field by limiting the size of the primary X-ray beam. - . The Dunlee manual "FORMAT M" collimators are intended for use in diagnostic X-ray systems during radiographic examinations. - . The Dunlee automatic "FORMAT A" collimators are intended for use in diagnostic X-ray systems during radiographic and fluoroscopic examinations. #### Safety information: - The Dunlee "FORMAT" collimator family will comply with the applicable requirements of the . performance standards for ionizing radiation emitting products (21CFR1020.30, 21CFR1020.31 and 21CFR1020.32). - . The Dunlee "FORMAT" collimator family will comply with national safety standards UL 2601-1 and CAN/CSA-C22.2 no. 601-1. - The Dunlee "FORMAT" collimator family will comply with international safety standards . IEC 60601-1, IEC 60601-1-2, IEC 60601-1-3, IEC 60601-2-28 and IEC 60601-2-43. ## Conclusion: The Dunlee "FORMAT" collimator family does not introduce any new indications for use, nor does the use of the devices result in any new potential hazard. Dunlee considers the FORMAT collimator family to be substantially equivalent with the predicate devices. {1}------------------------------------------------ Image /page/1/Picture/1 description: The image shows the logo for the Department of Health & Human Services USA. The logo is a circular seal with the words "DEPARTMENT OF HEALTH & HUMAN SERVICES USA" around the perimeter. Inside the circle is an abstract image of an eagle. JUL 2 1 2003 Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 Ms. Lynn Harmer Manager, Regulatory Submissions Philips Medical Systems 22100 Bothell Everett Highway BOTHELL WA 98021-8431 Re: K031597 Trade/Device Name: Dunlee "Format" Collimator Family Regulation Number: 21 CFR 892.1610 Regulation Name: Diagnostic x-ray beamlimiting device Regulatory Class: II Product Code: 90 IZW and IZX Dated: May 19, 2003 Received: June 9, 2003 Dear Ms. Harmer: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (OS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (sections 531-542 of the Act); 21 CFR 1000-1050. {2}------------------------------------------------ This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at one of the following numbers, based on the regulation number at the top of the letter: | 8xx.1xxx | (301) 594-4591 | |----------------------------------|----------------| | 876.2xxx, 3xxx, 4xxx, 5xxx | (301) 594-4616 | | 884.2xxx, 3xxx, 4xxx, 5xxx, 6xxx | (301) 594-4616 | | 892.2xxx, 3xxx, 4xxx, 5xxx | (301) 594-4654 | | Other | (301) 594-4692 | Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97) you may obtain. Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html. Sincerely yours, Nancy C. Brogdon Nancy C. Brogdon Director, Division of Reproductive, Abdominal and Radiological Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {3}------------------------------------------------ 510(k) Number (if known): K 0 3 /5 97 Device Name: DUNLEE "FORMAT" COLLIMATOR FAMILY The Format collimator family will be used in Radiography, Fluoroscopy, Cardio and Vascular Xray systems. It has the following functionality (configuration dependant): - X-ray field limitation (rectangular and circular); rectangular shuttering in some configurations . with direct user control at the collimator head (direct shutter control) - Simulation of X-ray field by a light field . - Measurement of source image distance (with an electronic or mechanical ruler) ● - Spectral filtering ● - Wedge filtering (semi-transparent filtering) - Dose measurement (Area Exposure Product Measurement device) . Format family consists of a manual version and automatic versions. The product configuration of the automatic version depends on the configuration of the X-ray system. It's a modular concept in which collimator functionalities can be added for radiographic or fluoroscopy applications, The automatic collimators have an ISO-CAN software interface with the system through which they receive system commands at open-close level. Concurrence of Center for Devices and Radiological Health, Office of Device Evaluation David G. Ingram Division Sign-Off ivision of Reproductive, Abdominal. and Radiological D 510(k) Number Prescription Use (Per 21 CFR 801.109) Indications for Use
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...