OPUS MAGNUM IMPLANT SYSTEM, MODEL OM-1500

K031083 · Opus Medical, Inc. · HTY · Jun 12, 2003 · Orthopedic

Device Facts

Record IDK031083
Device NameOPUS MAGNUM IMPLANT SYSTEM, MODEL OM-1500
ApplicantOpus Medical, Inc.
Product CodeHTY · Orthopedic
Decision DateJun 12, 2003
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 888.3040
Device ClassClass 2
AttributesTherapeutic

Indications for Use

The Opus Magnum Implant is intended for fixation of tendon to bone using a "silky" II Polydek® non-absorbable braided polyester or FiberWire® braided polyblend USP size #2 suture for the indications listed below. The Magnum system consists of a fixation device pre-loaded with suture snares in an inserter handle. The Magnum Implant is a knotless fixation device whereby surgical knots are not necessary for fixation. Bone stock must be adequate to allow proper placement.

Device Story

Opus Magnum Implant System (Model OM-1500) is a knotless bone fixation device for tendon-to-bone attachment. System includes fixation implant pre-loaded with suture snares within an inserter handle. Used by surgeons in clinical settings for rotator cuff repair. Device eliminates need for manual surgical knots. Operates by securing tendon to bone using Polydek or FiberWire sutures. Benefits include simplified fixation procedure and reduced surgical time.

Clinical Evidence

No clinical data provided; bench testing only.

Technological Characteristics

Metallic bone fixation fastener; knotless design; pre-loaded with suture snares in an inserter handle; utilizes Polydek or FiberWire USP size #2 sutures.

Indications for Use

Indicated for rotator cuff repair in the shoulder. Requires adequate bone stock for placement.

Regulatory Classification

Identification

A smooth or threaded metallic bone fixation fastener is a device intended to be implanted that consists of a stiff wire segment or rod made of alloys, such as cobalt-chromium-molybdenum and stainless steel, and that may be smooth on the outside, fully or partially threaded, straight or U-shaped; and may be either blunt pointed, sharp pointed, or have a formed, slotted head on the end. It may be used for fixation of bone fractures, for bone reconstructions, as a guide pin for insertion of other implants, or it may be implanted through the skin so that a pulling force (traction) may be applied to the skeletal system.

Submission Summary (Full Text)

{1}------------------------------------------------ Image /page/0/Picture/1 description: The image shows the logo for the U.S. Department of Health and Human Services. The logo is a circular emblem with the words "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" arranged around the perimeter. Inside the circle is a stylized image of an eagle or bird-like figure, composed of three curved lines that suggest the shape of a bird in flight. Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 ## JUN 1 2 2003 Mr. James W. Hart President/CEO Opus Medical, Inc. 27127 Calle Arroyo, Suite 1924 San Juan Capistrano, California 92675 K031083 Re: Trade Name: Opus Magnum™ Implant System - Model Number OM-1500 Regulation Number: 21 CFR 888.3040 Regulation Name: Smooth or threaded metallic bone fixation fastener Regulatory Class: II Product Code: HTY and MBI Dated: April 3, 2003 Received: April 30, 2003 Dear Mr. Hart: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. {2}------------------------------------------------ Page 2- Mr. James W. Hart This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at (301) 594-4659. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html. Sincerely yours, R. Mark N. Milliken Celia M. Witten, Ph.D., M.D. Director Division of General, Restorative and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {3}------------------------------------------------ Magnum TM Implant System KO31083 510(k) number (if known): ____________________________________________________________________________________________________________________________________________________ Magnum™ Implant System Device Name: Indications for Use: Magnum Implant System: The Opus Magnum Implant is intended for fixation of tendon to bone using a "silky" II Polydek® non-absorbable braided polyester or FiberWire® braided polyblend USP size #2 suture for the indications listed below. The Magnum system consists of a fixation device pre-loaded with suture snares in an inserter handle. The Magnum Implant is a knotless fixation device whereby surgical knots are not necessary for fixation. Bone stock must be adequate to allow proper placement. Indications: (1) Shoulder 1) Rotator Cuff Repair Mark N. Millican Division of General, Restorative and Neurological Devices KO3 1083 510(k) Number_ (PLEASE DO NOT WRITE BELOW THIS LINE -- CONTINUE ON ANOTHER PAGE IF NEEDED Concurrence of CDRH, Office of Device Evaluation (ODE) Prescription Use (Per 21 CFR 801.109) OR Over-The-Counter Use ____________
Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...