← Product Code [KWQ](/productcode/KWQ) · K024125

# HALM ZIELKE INSTRUMENTATION SYSTEM (K024125)

_Micomed Ortho GmbH · KWQ · Sep 22, 2003 · Orthopedic · SESE_

**Canonical URL:** https://fda.innolitics.com/device/K024125

## Device Facts

- **Applicant:** Micomed Ortho GmbH
- **Product Code:** [KWQ](/productcode/KWQ.md)
- **Decision Date:** Sep 22, 2003
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 888.3060
- **Device Class:** Class 2
- **Review Panel:** Orthopedic
- **Attributes:** Therapeutic

## Indications for Use

The Halm Zielke Instrumentation System is an anterior spinal fixation system indicated for spinal deformities in the thoracic and lumbar spine such as scoliosis, kyphosis, lordosis and thoracolumbar spinal instability caused by fracture.

## Device Story

Low-profile anterior spinal fixation system; components include Halm/HC plates, screws, threaded rods, fluted rods, and vertebral clamps. Used in thoracic and lumbar spine surgery. Surgeon attaches plates to lateral vertebral bodies with screws; connects threaded rod to screws; performs partial deformity correction; attaches pre-bent fluted rod; secures with head screws. Rod rotation achieves derotation and relordosation; reverse rotation in thoracic spine produces/enhances physiological kyphosis. Segmental compression/distraction adjusts lordosis/kyphosis. System provides structural stabilization to correct spinal deformities and treat instability.

## Clinical Evidence

Bench testing only. Biomechanical performance testing conducted per ASTM F1717-96 demonstrated the new components function in an equivalent manner to the predicate device.

## Technological Characteristics

Materials: Implant grade titanium (Ti 6AL 4V) per ASTM F136 or stainless steel (316 LS) per ASTM F1314. System includes plates, screws, threaded/fluted rods, and clamps. Mechanical fixation principle. No software or energy source.

## Regulatory Identification

A spinal intervertebral body fixation orthosis is a device intended to be implanted made of titanium. It consists of various vertebral plates that are punched into each of a series of vertebral bodies. An eye-type screw is inserted in a hole in the center of each of the plates. A braided cable is threaded through each eye-type screw. The cable is tightened with a tension device and it is fastened or crimped at each eye-type screw. The device is used to apply force to a series of vertebrae to correct “sway back,” scoliosis (lateral curvature of the spine), or other conditions.

## Predicate Devices

- Micomed Halm Zielke Instrumentation System ([K982006](/device/K982006.md))
- Zielke V.D.S. System ([K782061](/device/K782061.md))
- DePuy AcroMed MOSS Miami Spinal System ([K983583](/device/K983583.md))
- Kaneda Anterior Scoliosis System ([K974757](/device/K974757.md))

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

K024125 p1/2

202

 Premarket Notification for New Components for Micomed Halm Zielke Instrumentation System Reference 510(k) K982006 SEP 2 2 2003 December 12, 2002

ULT 22 LC

# Attachment 12

## MICOMED – HALM ZIELKE INSTRUMENTATION SYSTEM 510(K) SUMMARY

| Tradename:                  | Micomed Halm Zielke Instrumentation System                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                     |
|-----------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Generic Name:               | Spinal Intervertebral Body Fixation Orthosis                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                   |
| Classification:             | Class II (21 CFR 3060)                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                         |
| Company:                    | Micomed Ortho GmbH & Co. KG<br>Schorndorfer Strasse 96<br>Schorndorf 73614<br>Germany<br>Phone: 011 49 71 81 48 99 85 87<br>Fax: 011 49 71 81 48 99 84<br>info@micomed.com                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                     |
| Contact:                    | Corrine M. Bonfiglio, RAC<br>Tel: (858) 342-0344<br>Fax: (858) 481-2363<br>cbonfiglio@meister.net                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                              |
| Predicate<br>Devices:       | Micomed Halm Zielke Instrumentation System, 510(k) #K982006<br>Zielke V.D.S. System, 510(k) #K782061<br>DePuy AcroMed MOSS Miami Spinal System, 510(k) #K983583<br>Kaneda Anterior Scoliosis System, 510(k) #K974757                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                           |
| Description:                | The principal components of the Micomed Halm Zielke Instrumentation System,<br>which is a low profile spinal fixation system, are as follows: Halm and HC plates,<br>screws, threaded rods, standard hex nuts for threaded rods, fluted rods, and<br>vertebral clamps (double and single hole). Additional instrumentation includes:<br>awls, wrenches, insertion instruments for rods and screws, vertebral and end<br>vertebra screws, top loading screws and set screws, rod pushers and rod benders,<br>grip and compression tongs, rod cutter and distraction instrument.<br>The principal components of the Micomed Halm Zielke Instrumentation are used<br>in the following manner: First, the most cranial and caudal Halm plates are each<br>attached to the lateral aspect of the vertebral body with two screws (countersunk,<br>Zielke), and then additional plates are attached as needed. The threaded rod is<br>then connected to the top of the Zielke screws and anchored with the standard hex<br>nuts. Once the threaded rod is properly connected to the Halm plates, partial<br>correction of the scoliotic deformity is performed before attaching the pre-bent<br>fluted rod by closing the lid of the Halm plate and securing with the head screws.<br>The secured fluted rod can then be rotated around its longitudinal axis to achieve<br>and appropriate level of derotation and relordosation. If this system is used in the<br>thoracic spine, rod rotation is performed in reverse to produce or enhance<br>physiological kyphosis. Additionally, segmental compression or distraction can be<br>used to increase or decrease lordosis or kyphosis, as desired. |
|                             | 510(k) Summary - continued                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                     |
| Material:                   | The components of the Micomed Halm Zielke Instrumentation are manufactured<br>from implant grade titanium (Ti 6AL 4V) conforming to ASTM F136 or implant<br>grade stainless steel (316 LS) conforming to ASTM F1314 specifications.                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                            |
| Indications:                | The Halm Zielke Instrumentation System is an anterior spinal fixation system<br>indicated for spinal deformities in the thoracic and lumbar spine such as scoliosis,<br>kyphosis, and lordosis and thoracolumbar spinal instability caused by fracture.                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                        |
| Performance:                | Testing was conducted per ASTM F1717-96. The new components have been<br>shown to have acceptable biomechanical performance and to function in an<br>equivalent manner to the predicated device.                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                               |
| Substantial<br>Equivalence: | The new components for the Micomed Halm Zielke Instrumentation System are<br>substantially equivalent in function, performance and intended use to the predicate<br>Halm Zielke instrumentation cleared for market entry under 510(k) #K982006 on<br>January 20, 1999; the Zielke V.D.S System cleared for market entry on March 21,<br>1979; the DePuy AcroMed MOSS Miami Spinal System, cleared for market entry<br>under 510(k) #K983583 on December 3, 1998; and the Kaneda Anterior Scoliosis<br>System (KASS), cleared for market entry under 510(k) #K974757, on March 5,<br>1998.                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                      |

{1}------------------------------------------------

K024125 p2/2

Premarket Notification for New Components for Micomed Halm Zielke Instrumentation System Reference 510(k) K982006

December 12, 2002

{2}------------------------------------------------

DEPARTMENT OF HEALTH & HUMAN SERVICES

DEPARTMENT OF HEALTH & HUMAN SERVICES - USA

Public Health Service

Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850

SEP 2 2 2003

Micromed Ortho GmbH & Co. KG c/o Ms. Corrine M. Bonfiglio, RAC 13195 Seagrove Street San Diego, California 92130

Re: K024125

Trade/Device Name: Halm Zielke Instrumentation System Regulatory Number: 21 CFR 888.3060 Regulation Name: Spinal intervertebral body fixation orthosis Regulatory Class: II Product Code: KWQ Dated: August 7, 2003 Received: August 11, 2003

Dear Ms. Bonfiglio:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies .- You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.

{3}------------------------------------------------

### Page 2 - Ms. Corrine M. Bonfiglio, RAC

This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html

Sincerely yours,

e. Mark N Milliman

Celia M. Witten, Ph.D., M.D. Director Division of General, Restorative and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{4}------------------------------------------------

Premurket Notification for New Components for Micomed Halm Zielke Instrumentation System Reference 510(k) K982006 December 12, 2002

#### Attachment 11

#### Statement of Indication for Use

510(k) Number: KD24125

Device Name: Micomed Halm Zielke Instrumentation System

Indications for Use:

The Halm Zielke Instrumentation System is an anterior spinal fixation system indicated for spinal deformities in the thoracic and lumbar spine such as scoliosis, kyphosis, lordosis and thoracolumbar spinal instability caused by fracture.

## (PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)

Concurrence of CDRH, Office of Device Evaluation (ODE)

for Mark A. Milliman
Division Sign Off

Di ision of General, Restorative and Neurological Devices

510(k) Number -

i(k) Number ***_***__ KV24/23

Prescription Use (Per 21 CFR 801.109) OR

Over-The Counter Use

(Optional Format 1-2-96)

201

---

**Source:** [https://fda.innolitics.com/device/K024125](https://fda.innolitics.com/device/K024125)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
