K023060 · Acculaser, Inc. · NHN · Mar 19, 2004 · Physical Medicine
Device Facts
Record ID
K023060
Device Name
ACCULASER PRO4
Applicant
Acculaser, Inc.
Product Code
NHN · Physical Medicine
Decision Date
Mar 19, 2004
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 890.5500
Device Class
Class 2
Attributes
Therapeutic
Indications for Use
The Acculaser™ Pro4 is indicated for adjunctive use in providing temporary relief of pain associated with iliotibial band syndrome.
Device Story
Acculaser™ Pro4 is a low-level laser therapy (LLLT) device; emits non-thermal infrared energy at 830 nm. Used as adjunctive therapy for temporary relief of pain and disability associated with iliotibial band syndrome (ITBS). Device operates by delivering infrared light to target tissues; intended for clinical use. Healthcare providers utilize the device to provide non-invasive pain management; output affects clinical decision-making by offering an alternative or supplemental treatment modality for ITBS patients. Benefits include temporary pain relief and reduction of associated disability.
Clinical Evidence
Performance testing included both bench testing and clinical performance data. Results demonstrated the device is safe and effective for providing adjunctive therapy for the temporary relief of pain and disability associated with ITBS.
Technological Characteristics
Low-level laser therapy device; emits non-thermal infrared energy at 830 nm. Class II device under 21 CFR 890.5500 (Product Code NHN).
Indications for Use
Indicated for adjunctive use in providing temporary relief of pain associated with iliotibial band syndrome.
Regulatory Classification
Identification
An infrared lamp is a device intended for medical purposes that emits energy at infrared frequencies (approximately 700 nanometers to 50,000 nanometers) to provide topical heating.
Special Controls
*Classification.* Class II (special controls). The device, when it is an infrared therapeutic heating lamp, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 890.9.
{0}------------------------------------------------
023660
1/2
Sponsor: PhotoThera, Inc.
1 - 5 - 6 - 5 - 6 - 5 - 6 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 1
MAR 1 9 2004
## 510(k) SUMMARY-Acculaser™ Pro4
ubmitter Name: Photo Thera, Incorporatud Career Children Comments of Arm
| Submitter Address: | 2260 Rutherford Rd.<br>Suite 101<br>Carlsbad, CA 92008 |
|----------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Contact Person: | Jackson Streeter, M.D.<br>Chief Executive Officer |
| Phone Number: | 760-496-3700 |
| Fax Number: | 760-496-3707 |
| Email: | jstreeter@photothera.com |
| Date Prepared: | September 13, 2002 |
| Device Trade Name: | Acculaser™ Pro 4 |
| Device Common Name: | Low level laser therapy device |
| Classification Name: | Lamp, Non-heating, for Adjunctive Use in Pain Therapy<br>21 CFR 890.550; NHN |
| Predicate Devices: | K020657, Acculaser, Inc., Acculaser™ Pro LLLT<br>K010175, MicroLight Corp., MicroLight 830™ Laser System<br>K012580, TUCO Innovations, Inc., TUCO Erchonia PL2000 |
| Device Description: | The Acculaser™ Pro4 is a low level laser therapy device. It is<br>non-thermal and emits infrared energy at 830 nm. |
| Intended Use: | The Acculaser™ Pro4 is indicated for adjunctive use in providing<br>temporary relief of pain associated with iliotibial band syndrome. |
.
{1}------------------------------------------------
| Sponsor:<br>PhotoThera, Inc. | K02 3060 2/2<br>Acculaser™ Pro4<br>Traditional 510(k) Premarket Notification |
|------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Performance Testing: | Bench test and clinical performance data demonstrate that the<br>Acculaser™ Pro4 low level laser therapy device is safe and<br>effective in providing adjunctive therapy for the temporary relief of<br>pain and disability associated with ITBS. |
| Conclusion: | Based on the same intended use and similarity in design and<br>technological characteristics, the Acculaser™ Pro4 is substantially<br>equivalent to the predicate devices. |
.
:
.
.
{2}------------------------------------------------
Image /page/2/Picture/1 description: The image shows the logo for the U.S. Department of Health and Human Services. The logo consists of a stylized eagle with three lines representing its body and wings. The eagle is enclosed in a circle with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" written around the circumference of the circle.
Public Health Service
MAR 1 9 2004
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
PhotoThera, Inc. c/o Ms. Patsy Trisler Regulatory Consultant 5610 Wisconsin Avenue, Suite 304 Chevy Chase, Maryland 20815
Re: K023060
Trade/Device Name: Acculaser™ Pro 4 Regulation Number: 21 CFR 890.5500 Regulation Name: Lamp, non-heating, for adjunctive use in pain therapy Regulatory Class: II Product Code: NHN Dated: December 22, 2004 Received: December 22, 2004
Dear Ms. Trisler:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration. listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
{3}------------------------------------------------
Page 2 - Ms. Patsy Trisler
This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at (301) 594-4659. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html
Sincerely yours,
Miriam C Provost
Celia M. Witten, Ph.D., M.D. Director Division of General, Restorative and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{4}------------------------------------------------
Sponsor: PhotoThera, Inc.
610(k) Number (if known):
K023060
Device Name;
Acculaser™ Pro4
Indications for Use:
The Acculaser™ Pro4 is indicated for adjunctive use in providing temporary relief of pain associated with iliotibial band syndrome.
(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)
| Concurrence of CDRH; Office of Device Evaluation (ODE) | |
|--------------------------------------------------------|------------------------------------------------------------------------------------------------------------------|
| Prescription Use<br>(Per 21 CFR 801.109) | <b>X</b> |
| | OR |
| | Over-The-Counter Use |
| | |
| | (Optional Format 1-2-96) |
| | <i>Miriam C. Provost</i><br>(Division Sign-Off)<br>Division of General, Restorative,<br>and Neurological Devices |
| 510(k) Number | K023060 |
Section 4.0