NAVIGUS MANUAL DISPOSABLE MICRODRIVE WITH DIGITAL DISPLAY, MODELS MI-1000 & MI-1010

K022100 · Image-Guided Neurologics, Inc. · HAW · Sep 25, 2002 · Neurology

Device Facts

Record IDK022100
Device NameNAVIGUS MANUAL DISPOSABLE MICRODRIVE WITH DIGITAL DISPLAY, MODELS MI-1000 & MI-1010
ApplicantImage-Guided Neurologics, Inc.
Product CodeHAW · Neurology
Decision DateSep 25, 2002
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 882.4560
Device ClassClass 2
AttributesTherapeutic

Indications for Use

The Manual Disposable Micro-drive with Digital Display is intended to be used in conjunction with the Navigus™ family of Trajectory Guides for the precise positioning of microelectrodes, stimulating electrodes, implantable electrodes, or other instruments in the brain or nervous system.

Device Story

Manual disposable microdrive with digital display; used with Navigus trajectory guides for stereotaxic neurosurgery. Device provides precise mechanical positioning of electrodes or instruments in brain/nervous system. Operated by neurosurgeons in clinical settings. Digital display provides real-time feedback on instrument depth/positioning. Facilitates accurate targeting for neurosurgical interventions; improves procedural precision.

Clinical Evidence

No clinical data provided; bench testing only.

Technological Characteristics

Manual stereotaxic instrument; disposable microdrive; digital display for depth measurement. Class II device (Product Code HAW).

Indications for Use

Indicated for use in patients requiring precise positioning of microelectrodes, stimulating electrodes, implantable electrodes, or other instruments within the brain or nervous system during stereotaxic procedures.

Regulatory Classification

Identification

A stereotaxic instrument is a device consisting of a rigid frame with a calibrated guide mechanism for precisely positioning probes or other devices within a patient's brain, spinal cord, or other part of the nervous system.

Submission Summary (Full Text)

{0}------------------------------------------------ Image /page/0/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo features a stylized caduceus symbol, which is often associated with healthcare. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES • USA" is arranged in a circular pattern around the symbol. The logo is presented in black and white. Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 SEP 2 5 2002 Image-Guided Neurologics, Inc. David M. Lee Director of Regulatory Affairs 2290 West Eau Gallie Boulevard Melbourne, Florida 32935 Re: K022100 Trade/Device Name: Navigus Manual Disposable Microdrive with Digital Display Regulation Number: 882.4560 Regulation Name: Stereotaxic instrument Regulatory Class: Class II Product Code: HAW Dated: June 27, 2002 Received: June 28, 2002 Dear Mr. Lee: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050, {1}------------------------------------------------ Page 2 – Mr. David M. Lee This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for vour device on our labeling regulation (21 CFR Part 801 and additionally 21 CFR Part 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4659. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html Sincerely yours, Sincerely yours, Mark N Millican Celia M. Witten, Ph.D., M.D. Director Division of General, Restorative and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {2}------------------------------------------------ 510(k) NUMBER (IF KNOWN) : KO22/00 DEVICE NAME: INDICATIONS FOR USE: Intended Use: The Manual Disposable Micro-drive with Digital Display is intended to be used in conjunction with the Navigus™ family of Trajectory Guides for the precise positioning of microelectrodes, stimulating electrodes, implantable electrodes, or other instruments in the brain or nervous system. (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED.) Concurrence of CDRH, Office of Device Evaluation (ODE) OR Prescription Use (Per 21 CFR 801.109) (Division Sign-Off) Division of General Restorative and Neurological Devices K02210 510(k) Number Over-The-Counter-Use (Optional Format 1-2-
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.