J&S MEDICAL SENTRY URINE DIPSTICK CONTROL

K022085 · J & S Medical Assoc., Inc. · JJW · Jul 25, 2002 · Clinical Chemistry

Device Facts

Record IDK022085
Device NameJ&S MEDICAL SENTRY URINE DIPSTICK CONTROL
ApplicantJ & S Medical Assoc., Inc.
Product CodeJJW · Clinical Chemistry
Decision DateJul 25, 2002
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 862.1660
Device ClassClass 1

Indications for Use

J&S Medical Associates Sentry dipstick urine controls are intended to be used by laboratory technicians in order to verify the performance of various urine dipsticks as a part of the laboratory's quality control practices.

Device Story

Sentry Urine Dipstick Control consists of three liquid levels prepared with human and animal proteins and chemical additives. These controls interact with urine dipstick reactant pads to produce color changes mimicking normal or abnormal urine samples. Used in clinical laboratory settings by technicians to verify dipstick performance. Level 1 tests for leukocytes, nitrite, urobilinogen, protein, blood, ketone, bilirubin, glucose, hCG, and specific gravity. Level 2 tests for ascorbic acid, pH, and specific gravity. Level 3 tests for pH and specific gravity. Healthcare providers use the resulting color changes (visual or instrument-read) to confirm the accuracy and reliability of their urinalysis dipstick testing, ensuring valid clinical results for patient diagnosis.

Clinical Evidence

Bench testing only. Stability and performance were assessed by incubating controls at 4°C, ambient, 25°C, and 37°C for 65 days. Performance was verified using Quidel and Bayer dipsticks, evaluated both visually and via instruments (Behring Rapimat II, Bayer Clinitek 100). hCG stability in Level 1 was verified over 120 days using the Quidel QuickVue One-Step hCG Combo lateral flow device. Results confirmed shelf life of two years and open-vial stability of at least two months.

Technological Characteristics

Liquid-based quality control material containing human and animal proteins and chemical additives. Three levels with varying pH, specific gravity, and analyte concentrations. Compatible with various commercial urine dipsticks. Stability validated for two years (closed) and two months (open).

Indications for Use

Indicated for use by laboratory technicians to verify the performance of urine dipsticks as part of laboratory quality control practices.

Regulatory Classification

Identification

A quality control material (assayed and unassayed) for clinical chemistry is a device intended for medical purposes for use in a test system to estimate test precision and to detect systematic analytical deviations that may arise from reagent or analytical instrument variation. A quality control material (assayed and unassayed) may be used for proficiency testing in interlaboratory surveys. This generic type of device includes controls (assayed and unassayed) for blood gases, electrolytes, enzymes, multianalytes (all kinds), single (specified) analytes, or urinalysis controls.

Predicate Devices

Submission Summary (Full Text)

{1}------------------------------------------------ # JUL 2 5 2002 ### 510(K) Summary This summary of 510(k) safety and effectiveness information is being submitted in accordance with the requirements of SMDA 1990 and 21 CFR 807.92 | The assigned 510(k) number is : | K022085 | |---------------------------------|---------| |---------------------------------|---------| | | Submitter Information | |--|-----------------------| |--|-----------------------| | Submitter's Name: | J&S Medical Associates | |------------------------------------|-------------------------------------------------| | Address: | 35 Tripp Street, Bldg.1<br>Framingham, MA 01702 | | Contact Person: | Dr. Paul MacDonnell | | Phone: | 1-800-229-6000 ext. 157 | | Fax: | (508) 370-4554 | | Establishment Registration Number: | 1218982 | Date Prepared: 06/24/2002 #### 2) Identification of Device | Device Name: | Urine Dipstick Control | |--------------------------|---------------------------------------------| | Proprietary/ Trade Name: | J&S Medical Sentry Urine Dipstick Control | | Common Name: | Urinalysis Controls | | Classification Name: | Urinalysis Controls (Assayed and Unassayed) | | Device Classification: | 1 | | Regulation Number: | 21 CFR 862.1660 | | Panel: | Clinical Chemistry | | Product Code: | JJW | {2}------------------------------------------------ 3) Identification of the Predicate Device: Predicate Device Name: The Dropper urine dipstick control Quantimetrix Corporation Manufacturer: 510(k) #: Unknown - 4.0 Description of the Device The three Sentry controls are prepared with human and animal proteins and with various chemical additives. These chemicals interact with the dipstick reactant pads to produce specific color changes that mimic actual normal and/or abnormal urine samples. - 4.1 Sentry Level 1 Control is designed to test positive for leukocytes, nitrite. urobilinogen, protein, blood, ketone, bilirubin, and glucose with dipsticks. In addition, this control will have a pH of about 7 with an elevated specific gravity and will test positive for hCG. - 4.2 Sentry Level 2 Control is designed to test positive for ascorbic acid, have a pH of about 5, and a moderately elevated specific gravity. - 4.3 Sentry Level 3 Control is designed to have a pH of about 7 with a low specific gravity. - 5.0 Intended Use The controls are intended to be used by laboratory technicians in order to verify the performance of urine dipsticks made by various companies. - 6.0 Substantial Equivalence - 6.1 The Sentry Urine Dipstick Controls (Levels 1, 2, and 3) and the Quantimetrix Controls (Level 1 and 2) are supplied as liquids and do not require further treatment before use. - 6.2 The Sentry and Quantimetrix controls are used to verify the performance of various urine dipsticks. - 6.3 The Sentry and the Quantimetrix Controls will have value assignments to account for variations in manufacturers' dipstick formulations. {3}------------------------------------------------ #### 7.0 Assignment of Expiration date - Samples of the three controls were incubated at 4º C, ambient (for open 7.1 vial room temperature stability), 25° C, and 37° C for 65 days. - The stability of the three controls were assessed as follows: 7.2 - Solutions were tested at frequent intervals using Quidel dipsticks. 7.2.1 The results were recorded visually by comparing reactant pad color intensity to the color chart supplied by Quidel; the results also were measured with the Behring Rapimat II instrument. After 65 days incubation of the controls at 37°, all of the controls performed within specifications, indicating a shelf life of two years for the three controls (Table I). - 7.2.2 The stability of the controls also was assessed by testing with Baver dipsticks visually and with the Bayer Clinitek 100 instrument. The stability data with the Bayer strips are similar to that with the Quidel strips indicating an expiration date of two vears for the three controls (Table II). - The stability of hCG in Sentry Level 1 was assessed by testing the 7.2.3 solution at periodic intervals up to 120 at days 4°. 25°, and 37° C. When tested with Quidel QuickVue One-Step hCG Combo lateral flow device a positive response was detected after 120 days. An expiration date of two years can be assigned (Table III). - 8.0 Open vial stability of Sentry Controls 1, 2, and 3 Samples of the Sentry Urine Dipstick Control Levels 1, 2, and 3 were stored at ambient temperature (19° C to 22° C). Quidel dipsticks and Bayer dipsticks were used to test the controls at periodic intervals for 65 days. At day 65, the controls reacted within specifications, indicating open vial shelf life of at least two months for the three controls (Tables IV, V) {4}------------------------------------------------ Image /page/3/Picture/0 description: The image shows the seal of the Department of Health & Human Services (USA). The seal features the department's name in a circular arrangement around a stylized caduceus symbol. The caduceus is depicted with three intertwined strands, representing health, services, and human aspects. ### DEPARTMENT OF HEALTH & HUMAN SERVICES Public Health Service Food and Drug Administration 2098 Gaither Road Rockville MD 20850 # JUL 2 5 2002 Ms. Joslyn S. Murphy Ouality Assurance Manager J&S Medical Associates 35 Tripp Street, Bldg. 1 Framingham. MA 01702 Re: k022085 > Trade/Device Name: Sentry urine dipstick control Regulation Number: 21 CFR 862.1660 Regulation Name: Quality control material (assayed and unassayed) Regulatory Class: Class I Product Code: JJW Dated: June 24, 2002 Received: June 27, 2002 Dear Ms. Murphy: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (OS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. {5}------------------------------------------------ Page 2 - This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and ' additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4588. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled. "Misbranding by reference to premarket notification" (21CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers International and Consumer Assistance at its toll-free number (800) 638-2041 or. (301) 443-6597 or at its internet address "http://www.fda.gov/cdrh/dsma/dsmamain.html". Sincerely yours, Steven Butman Steven I. Gutman, M.D., M.B.A. Director Division of Clinical Laboratory-Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {6}------------------------------------------------ ## INDICATIONS FOR USE STATEMENT 510(K) Number (if known): Device Name: Sentry urine dipstick control Indications for Use: J&S Medical Associates Sentry dipstick urine controls are intended to be used by laboratory technicians in order to verify the performance of various urine dipsticks as a part of the laboratory's quality control practices. Lein Cooper (Division Sign-Off) Division of Clinical Laboratory Devices Kho 510(k) Number_ (PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) Description Use X (Per 21 CFR 801.109) OR Over-The-Counter Use
Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...