DAUM-LECTRIC MRI DRILLING MACHINE

K021098 · Mri Devices Daum GmbH · ERL · Dec 3, 2002 · Ear, Nose, Throat

Device Facts

Record IDK021098
Device NameDAUM-LECTRIC MRI DRILLING MACHINE
ApplicantMri Devices Daum GmbH
Product CodeERL · Ear, Nose, Throat
Decision DateDec 3, 2002
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 874.4250
Device ClassClass 2
AttributesTherapeutic

Indications for Use

The Daum p-lectric Drilling Machine is a piezoelectrically driven hand held drill intended to assist the surgeon to access bony tissue. The Daum p-lectric Drilling Machine can drill into hard and soft bone tissue to create a small hole or to obtain bony tissue samples. The Daum p-lectric Drilling Machine is designed to be used inside or close to an MRI Unit up to 1.5 Tesla.

Device Story

Handheld, piezoelectrically driven surgical drill; used by surgeons to access bony tissue, create holes, or obtain samples. Operates within or near MRI units (up to 1.5 Tesla). Provides mechanical drilling capability for bone tissue access.

Clinical Evidence

No clinical data provided; bench testing only.

Technological Characteristics

Piezoelectrically driven handheld surgical drill. Designed for MRI compatibility up to 1.5 Tesla.

Indications for Use

Indicated for use by surgeons to access bony tissue, including drilling into hard and soft bone to create holes or obtain tissue samples. Designed for use in or near MRI environments up to 1.5 Tesla.

Regulatory Classification

Identification

An ear, nose, and throat electric or pneumatic surgical drill is a rotating drilling device, including the handpiece, that is intended to drive various accessories, such as an ear, nose, and throat bur (§ 874.4140), for the controlled incision or removal of bone in the ear, nose, and throat area.

Submission Summary (Full Text)

{1}------------------------------------------------ ## DEPARTMENT OF HEALTH & HUMAN SERVICES Image /page/0/Picture/1 description: The image shows the seal of the Department of Health & Human Services - USA. The seal is circular and contains the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" around the perimeter. In the center of the seal is an abstract image of an eagle. 9200 Corporate Boulevard Rockville MD 20850 DEC 0 3 .2002 Smith Associates c/o E.J. Smith P.O. Box 4341 Crofton, MD 21114 Re: K021098 Trade/Device Name: Daum x-lectric Drilling Machine Regulation Number: 21 CFR 874.4250 Regulation Name: Ear, nose and throat electric or pneumatic surgical drill Regulatory Class: Class II Product Code: ERL Dated: September 17, 2002 Received: September 19, 2002 Dear Mr. Smith: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. {2}------------------------------------------------ ## Page 2 - This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 21 CFR Part 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4613. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97), Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address . http://www.fda.gov/cdrh/dsma/dsmamain.html Sincerely yours, A. Ralph Rosenthal A. Ralph Rosenthal, M.D. Director Division of Ophthalmic and Ear, Nose and Throat Devices Office of Device Evaluation Center for Devices and Radiological Health {3}------------------------------------------------ 510(k) Number: K021098 Device Name: Daum n-lectric Drilling. Machi Classification Panel: Indications for Use: - The Daum p-lectric Drilling Machine is a piezoelectrically driven hand held drill intended to assist the surgeon to access bony tissue. The Daum p-lectric Drilling Machine can drill into hard and soft bone tissue to create a small hole or to obtain bony tissue samples. The Daum p-lectric Drilling Machine is designed to be used inside or close to an MRI Unit up to 1.5 Tesla. (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) Prescription Use: Over-the-Counter Use: Karen L Baker (Division Sign-Off) Division of Ophthalmic Ear, Nose and Throat Devises 510(k) Number K021098
Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...