K020078 · Exactech, Inc. · MQV · Feb 27, 2004 · Orthopedic
Device Facts
Record ID
K020078
Device Name
EXACTECH RESORBABLE BONE PASTE
Applicant
Exactech, Inc.
Product Code
MQV · Orthopedic
Decision Date
Feb 27, 2004
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 888.3045
Device Class
Class 2
Attributes
Therapeutic
Indications for Use
Exactech Resorbable Bone Paste is intended for use as a bone graft extender (extremities, spine, pelvis) and as a bone void filler for bony voids or gaps of the extremities and pelvis that are not intrinsic to the stability of the bony structure. These defects may be surgically created osseous defects or osseous defects created from traumatic injury to the bone. Exactech Resorbable Bone Paste may be used with rigid fixation systems.
Device Story
Exactech Resorbable Bone Paste is an implantable bone graft substitute consisting of demineralized bone matrix (DBM) mixed with a bioinert polyethylene glycol (PEG) polymer carrier. Provided as an aseptic, single-use, ready-to-use paste. Intended for surgical application by clinicians to fill osseous defects in extremities, spine, and pelvis. The PEG carrier facilitates handling and delivery of the DBM. Upon implantation, the DBM is resorbed and replaced by new host bone during the healing process. The device is not intended to provide structural support; it may be used in conjunction with rigid fixation systems. The product is derived from a single human donor and processed to ensure biocompatibility and viral reduction.
Clinical Evidence
No clinical data provided. Bench testing includes osteoinductivity assessment in an athymic mouse model (implanted in gastrocnemius muscle, explanted at 35 days, scored 1-4) and viral reduction studies (HAV, HIV-1, PPV, PrV) conducted by a CLIA-certified laboratory to validate the demineralization process.
Technological Characteristics
Composition: Demineralized bone matrix (DBM) in a polyethylene glycol (PEG) polymer carrier. Processing: Aseptic manufacture, single-donor human tissue. Osteoinductivity: Verified via athymic mouse model per Schwartz et al. (1996) and ASTM Draft Standard Guide for the Assessment of Bone Inductive Material. Sterilization: Aseptic processing. Form factor: Paste.
Indications for Use
Indicated for use as a bone graft extender and bone void filler in extremities, spine, and pelvis for non-structural bony voids or gaps resulting from surgery or trauma. Contraindicated for sites requiring structural support during healing, sites with active infection, and patients with known sensitivity to Polymixin Sulfate B or Bacytracin.
Regulatory Classification
Identification
A resorbable calcium salt bone void filler device is a resorbable implant intended to fill bony voids or gaps of the extremities, spine, and pelvis that are caused by trauma or surgery and are not intrinsic to the stability of the bony structure.
Special Controls
*Classification.* Class II (special controls). The special control for this device is the FDA guidance document entitled “Class II Special Controls Guidance: Resorbable Calcium Salt Bone Void Filler Device; Guidance for Industry and FDA.” See § 888.1(e) of this chapter for the availability of this guidance.
{0}------------------------------------------------
## FEB 27 2004
## 510(k) Summary of Safety and Effectiveness
This 510(k) Summary for Exactech Resorbable Bone Paste is provided as required per Section 513(1)(3) of the Food, Drug and Cosmetic Act.
| 1. Submitter: | Exactech Inc.<br>2320 NW 66th Court<br>Gainesville, Florida 32653<br>Telephone 352-377-1140<br>Fax 352-378-2617 |
|------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------|
| Contact person: | Steve Lin, D.Sc<br>Vice President, Advanced Technology & Business Development<br>Exactech Inc.<br>Telephone 352-377-1140<br>Fax 352-378-2617 |
| Date of original submission: | 01-08-2001 |
| FDA Establishment Number | 1038671 |
- 2. Proprietary Name: Exactech Resorbable Bone Paste Common Name: Bone void filler Product Code: MQV Device Class: Not classified Classification Panel: Orthopaedic
#### 3. Legally Marketed Devices for Substantial Equivalence Comparison:
| Product Code | Manufacturer | 510(k) Number | Product |
|--------------|-----------------------|---------------|--------------------------------------------------------------|
| MQV | Wright | K963562 | Wright Plaster of Paris Pellets |
| MQV | EBI | K011386 | EBI Osteostim Granules –<br>Resorbable Bone Graft Substitute |
| MQV | Neu Coll Laboratories | K000122 | Collagraft Strip Bone Graft Matrix |
#### Comparison to the Predicate Device(s): 4.
Exactech Resorbable Bone Paste shares the same function and intended use and therefore is substantially equivalent to Wright Medical - Plaster of Paris (Osteoset), Neu Coll Laboratories -Collagraft Strip and EBI - EBI OsteoStim Granules - Resorbable Bone Graft Substitute as a bone void filler.
{1}------------------------------------------------
## 510(k) Summary of Safety and Effectiveness
The polymer carrier used in Exactech Resorbable Bone Paste absorbs in-vivo and is used solely for the ease of handling and delivery of DBM.
#### Device Description: 5.
Exactech Resorbable Bone Paste is a mixture of demineralized bone matrix (DBM) in a biginert polvethylene divcol (PEG) based polymer and is provided as an aseptic manufacture single use. ready to use implantable device derived from a single donor. DBM resorbs and is replaced with new bone during the healing process.
#### Indications for Use 6.
Exactech Resorbable Bone Paste is intended for use as a bone graft extender (extremities, spine, pelvis) and as a bone void filler for bony voids or gaps of the extremities and pelvis that are not intrinsic to the stability of the bony structure. These defects may be surgically created osseous defects or osseous defects created from traumatic injury to the bone.
Exactech Resorbable Bone Paste may be used with rigid fixation systems.
#### 7. Contraindications:
Exactech Resorbable Bone Paste is not intended to provide structural support during the healing process, therefore, Exactech Resorbable Bone Paste is contraindicated in cases where structural support of the skeletal system is required by the graft during healing.
This allograft should not be implanted into sites with an active infection.
Polymixin Sulfate B and Bacytracin are used in processing this graft and trace amounts remain. Since it is impossible to quantify the levels at which any individual may have an allergic response, this product is contraindicated in patients with known sensitivity.
#### 8. Safety and Effectiveness Information:
Human demineralized bone used in Exactech Resorbable Bone Paste is single-donor processed. biocompatible, safe and effective for the repair of bone defects. Exactech Resorbable Bone Paste is aseptic manufactured for single patient use.
The polymer carrier used in Exactech Resorbable Bone Paste is bioinert and biocompatible with host tissue and presents no new safety issues.
The biocompatibility and effically manufactured demineralized bone matrix has been established through its long history of safe and effective use as a human tissue for transplant without reported incidents of infection or complication. A viral reduction study was conducted by a CLIA certified testing laboratory using four virus models representing RNA, DNA,
Rev. 2-26-2004
{2}------------------------------------------------
### 510(k) Summary of Safety and Effectiveness
envelope and non-envelope virus, which included: 1) Hepatitis A Virus (HAV), non-enveloped, RNA-containing picornavirus 2) Human immunodeficiency virus type 1 (HIV-1) enveloped, RNA-containing retrovirus. 3) Porcine parvovirus (PPV) non-enveloped. DNA-containing parvovirus, which serves as a model for other parvovirus such as human parvovirus B19 and 4) Pseudorabies virus (PrV), enveloped. DNA-containing virus belonging to the Herpesviridae family and serves as a model for other herpesviruses such as Cytomegalovirus (CMV). This study demonstrates the demineralization process used on donor bone contained in Exactech Resorbable Bone Paste effectively eliminates or reduces the virus responsible for potential infectious disease, which include HIV and Hepatitis.
#### Non-Clinical Testing: ഴി
Each lot of DBM is screened for osteoinductivity potential, with only acceptable DBM being manufactured into Exactech Resorbable Bone Paste. Osteoinductivity of each lot of Exactech Resorbable Bone Paste is verified using a single test protocol and demonstrates the DBM and the product to be osteoinductive in the athymic mouse. Osteoinduction assay results in the athymic mouse model should not be interpreted to predict clinical performance in human subjects.
Test samples are implanted bilaterally into the castrocnemius muscle of 2 animals (total of 4 samples of each lot), explanted at day 35 and scored for osteoinductivity in accordance with the test protocols defined by Schwartz S. Melloniq, Jl. Carnes, Jr. DL. de la Fontaine J. Cochran DL. Dean DD, Boyan BD (1996) Ability of Commercial Demineralized Freeze-dried Bone Allograft to Induce New Bone Formation J. Perio 67:918-926 and the ASTM Draft Standard Guide for the Assessment of Bone Inductive Material. A score of 1-4 is assigned with:
- 1 = implant present no new bone or cartilage present
- 2 = endochondral ossification <25% implant site and/or new bone covering <25% of implant
- 3 = endochondral ossification 26-50% implant site and/or new bone covering 26-50% of implant
- 4 = >50% endochondral ossification and/or new bone covering > 50% of implant
A viral reduction study was conducted by a CLIA certified testing laboratory using four virus models representing RNA, DNA, envelope and non-envelope virus, which included: 1) Hepatitis A Virus (HAV), non-enveloped, RNA-containing picornavirus 2) Human immunodeficiency virus type 1 (HIV-1) enveloped, RNA-containing retrovirus, 3) Porcine parvovirus (PPV) non-enveloped, DNA-containing parvovirus, which serves as a model for other parvovirus such as human parvovirus B19 and 4) Pseudorabies virus (PrV), enveloped, DNA-containing virus belonging to the Herpesviridae family and serves as a model for other herpesviruses such as Cytomegalovirus (CMV). This study demonstrates the demineralization process used on donor bone contained in Exactech Resorbable Bone Paste significantly diminishes these model viruses and can reasonably be anticipated to diminish the titers of other viruses.
Rev. 2-26-2004
{3}------------------------------------------------
Image /page/3/Picture/1 description: The image shows the seal of the Department of Health & Human Services (HHS) of the United States. The seal features the department's name encircling a symbol. The symbol consists of three stylized human profiles facing right, stacked on top of each other, with flowing lines beneath them, possibly representing water or movement.
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
FEB 2 7 2004
Ms. Rebecca S. Roberts CTBS Sr. Regulatory Representative Tissue Bank Director Exactech 2320 NW 66th Court Gainesville, Florida 32653
Re: K020078
Trade Name: Exactech Resorbable Bone Paste Regulation Number: 21 CFR 888.3045 Regulation Name: Resorbable calcium salt bone void filler device Regulatory Class: Class II Product Code: MOV, MBP Dated: November 25, 2003 Received: December 1, 2003
Dear Ms. Roberts:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements. of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration
{4}------------------------------------------------
Page 2 - Ms. Rebecca S. Roberts CTBS
and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at (301) 594-4659. Also, please note the regulation entitled. "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html
Sincerely yours,
Sincerely yours,
L. Mark N. Milkman
Celia M. Witten, Ph.D. M.D. Director Division of General, Restorative and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{5}------------------------------------------------
# Exactech Resorbable Bone Paste
# Indications for Use
510(k) Number (if known):
K020078
Device Name:
Exactech Resorbable Bone Paste
Indications for Use:
Exactech Resorbable Bone Paste is intended for use as a bone graft extender (extremities, spine, pelvis) and as a bone void filler for bony voids or gaps of the extremities and pelvis that are not intrinsic to the stability of the bony structure. These defects may be surgically created osseous defects or osseous defects created from traumatic injury to the bone.
Exactech Resorbable Bone Paste may be used with rigid fixation systems.
Prescription Use X Over-The-Counter Use AND/OR (Part 21 CFR 801 Subpart D) (21 CFR 807 Subpart C) (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE OF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
l. Mark M. Millerson
Division of General, Restorative, and Neurological Devices
510(k) Number K020078
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Guidance alerts
New and changed FDA guidance documents, emailed as a daily digest.
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the ? button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only Software as a Medical Device, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (Software as a Medical Device), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.