K020071 · Quantel Medical · GEX · Apr 5, 2002 · General, Plastic Surgery
Device Facts
Record ID
K020071
Device Name
VIRIDIS DERMA LASER
Applicant
Quantel Medical
Product Code
GEX · General, Plastic Surgery
Decision Date
Apr 5, 2002
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 878.4810
Device Class
Class 2
Attributes
Therapeutic
Indications for Use
The Viridis Derma laser is intended for photocoagulation of pigmented lesions in dermatology. These include the following specific applications: Benign Vascular Lesions, Facial Telangiectasias, Port Wine Stains, Café au-lait, Erythrosis, Benign Pigmented Lesions, Cuperosis, Senile Lentigo, Keratoses, Hemangiomas (spider and cherry/ strawberry), Dermatosis Papulosis Nigra (DPN), Leg Telangiectasia - only as a complement to sclerotherapy and for small superficial red vessels. The Viridis Derma laser is labeled as a prescription device as follows: CAUTION: Federal (US) law restricts this device to sale by or on the order of a physician.
Device Story
Viridis Derma is a frequency-doubled Nd:YAG surgical laser emitting coherent light at 532 nm. Device used by physicians in clinical dermatology settings for photocoagulation of vascular and pigmented lesions. Laser energy targets specific chromophores in skin tissue to achieve therapeutic coagulation. Output is controlled by the clinician to treat conditions like telangiectasias, port wine stains, and hemangiomas. Benefits include precise, targeted treatment of benign skin lesions. Device is prescription-only.
Clinical Evidence
No clinical data provided; bench testing only.
Technological Characteristics
Frequency-doubled Nd:YAG laser; wavelength 532 nm; laser surgical instrument; Class II device; product code GEX.
Indications for Use
Indicated for dermatological photocoagulation of pigmented and benign vascular lesions in patients requiring treatment for conditions including facial telangiectasias, port wine stains, café au-lait, erythrosis, benign pigmented lesions, cuperosis, senile lentigo, keratoses, hemangiomas, dermatosis papulosis nigra, and small superficial red leg vessels (as complement to sclerotherapy).
Regulatory Classification
Identification
(1) A carbon dioxide laser for use in general surgery and in dermatology is a laser device intended to cut, destroy, or remove tissue by light energy emitted by carbon dioxide.(2) An argon laser for use in dermatology is a laser device intended to destroy or coagulate tissue by light energy emitted by argon.
Altus Family of CoolGlide Aesthetic Lasers (K003202)
Submission Summary (Full Text)
{0}------------------------------------------------
# APR = 5 2002
K 020071
#### SECTION 10
#### 510(k) SUMMARY
This 510(k) summary of safety and effectiveness for the Viridis Derma (frequency doubled I MD > ( ( ) sa is submitted in accordance with the requirements of SMDA 1990 and follows Office of Device Evaluation guidance concerning the organization and content of a 510(k) summary.
Applicant: QUANTEL MEDICAL
Address:
QUANTEL MEDICAL 21 rue Newton ZI du BREZET 63039 Clermont-Ferrand Cedex 2 FRANCE +33 (0)473 745 745 +33 (0)473 745 700 (Fax)
- Mr. Jean Abascal Contact Person: Regulatory Affairs Manager (+33) 169 29 17 25 (+33) 169 29 17 29 (Fax)
Preparation Date: December 2001 (of the Summary)
Viridis Derma Device Name:
Frequency Doubled Nd: Y AG Surgical Laser Common Name:
Laser surgical instrument for use in general and plastic surgery and in Classification dermatology (see: 21 CFR 878.4810). Name: Product Code: GEX Panel: 79
- The Viridis Laser (K001784): Nuvo-Lase 660 Laser System (K970667) Predicate device COMPACT KTP Laser (K983020); DioLite 532 Laser System (K964074); Nidek Dio-Lite 60 Laser System (K981447); Altus Family of CoolGlide Aesthetic Lasers (K003202)
Device description: The Viridis Derma frequency doubled Nd:YAG laser emits a beam of coherent light at 532 microns.
{1}------------------------------------------------
The Viridis Derma laser is intended for photocoagulation of pigmented Indications: lesions in dermatology.
These include the following applications:
Facial Telangiectasias Benign Vascular Lesions Café au-lait Port Wine Stains Benign Pigmented Lesions Erythrosis Senile Lentigo Cuperosis Hemangiomas (spider and cherry/ Keratoses Dermatosis Papulosis Nigra (DPN) strawberry) Leg Telangiectasia - only as a complement to sclerotherapy and for small superficial red vessels
The Viridis Derma laser will be labeled as a prescription device as follows:
CAUTION: Federal (US) law restricts the use of this device to licensed professionals
Performance Data: None required.
#### CONCLUSION:
Based on the information in the notification Quantel Medical concludes that the Viridis Derma frequency doubled Nd: YAG laser is substantially equivalent to the Viridis laser and to other cited legally marketed predicates, under the conditions of intended use (above).
{2}------------------------------------------------
### DEPARTMENT OF HEALTH & HUMAN SERVICES
Image /page/2/Picture/1 description: The image shows the words "Public Health Service" in a simple, sans-serif font. The text is black and appears to be on a white background. The words are arranged on a single line, with "Public Health" appearing before "Service".
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
Ouantel Medical c/o Mr. Roger W. Barnes 342 Sunset Bay Road Hot Springs, AR 71913
APR = 5 2002
Re: K020071
Trade/Device Name: Viridis Derma Laser Regulation Number: 878.4810 Regulation Name: Laser surgical instrument for use in general and plastic surgery and in dermatology Regulatory Class: II Product Code: GEX Dated: January 7, 2002
Received: January 9, 2002
Dear Mr. Barnes:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
{3}------------------------------------------------
## Page 2 - Mr. Roger W. Barnes
This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 21 CFR Part 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4659. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html
Sincerely yours,
Muriam C. Provost
For Celia M. Witten, Ph.D., M.D. Director Division of General, Restorative and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{4}------------------------------------------------
### SECTION 7
## INDICATIONS FOR USE STATEMENT
510(k) Number (if known): KO2007
Device Name:_Viridis Derma (Frequency doubled Nd: YAG laser)
Indications for Use Statement:
The Viridis Derma laser is intended for photocoagulation of pigmented lesions in dermatology.
These include the following specific applications:
| Benign Vascular Lesions | Facial Telangiectasias |
|----------------------------------|-----------------------------------------------------------------------------------------------------|
| Port Wine Stains | Café au-lait |
| Erythrosis | Benign Pigmented Lesions |
| Cuperosis | Senile Lentigo |
| Keratoses | Hemangiomas (spider and cherry/<br>strawberry) |
| Dermatosis Papulosis Nigra (DPN) | Leg Telangiectasia - only as a complement to sclerotherapy and for small superficial<br>red vessels |
The Viridis Derma laser is labeled as a prescription device as follows:
CAUTION: Federal (US) law restricts this device to sale by or on the order of a physician.
Musiaml-Provost
(Division Sign-Off) Division of General, Restorative and Neurological Devices
510(k) Number K020671
(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation
Prescription Use (Per 21 CFR 801.109)
OR
Over-The Counter Use _________________________________________________________________________________________________________________________________________________________