Mono-Dox, Monofilament Synthetic Absorbable Sutures are indicated for use in all types of soft tissue approximation, including use in pediatric cardiovascular tissue where growth is expected to occur and ophthalmic surgery. Mono-Dox suture is not indicated for use in adult cardiovascular tissue, microsurgery, and neural tissue. These sutures are useful where an absorbable suture with extended wound support (up to six weeks) is desirable.
Device Story
Mono-Dox is a sterile, monofilament, synthetic absorbable surgical suture; composed of polydioxanone. Used by surgeons for soft tissue approximation and ligation; provides extended wound support for up to six weeks. Device is absorbed by the body over time. Intended for clinical use in operating rooms or surgical settings. Benefits include extended tensile strength retention in tissues where an absorbable material is required, particularly in pediatric cardiovascular applications.
Clinical Evidence
No clinical data. Substantial equivalence is based on bench testing and comparison of material, design, and performance characteristics to the predicate device.
Technological Characteristics
Monofilament polydioxanone synthetic absorbable suture. Meets or exceeds USP 24 performance requirements. Sterilized; available in various sizes. No software or electronic components.
Indications for Use
Indicated for soft tissue approximation, including pediatric cardiovascular tissue (where growth is expected) and ophthalmic surgery. Contraindicated for adult cardiovascular tissue, microsurgery, and neural tissue.
Regulatory Classification
Identification
An absorbable polydioxanone surgical suture is an absorbable, flexible, sterile, monofilament thread prepared from polyester polymer poly (p-dioxanone) and is intended for use in soft tissue approximation, including pediatric cardiovascular tissue where growth is expected to occur, and ophthalmic surgery. It may be coated or uncoated, undyed or dyed, and with or without a standard needle attached.
Special Controls
*Classification.* Class II (special controls). The special control for the device is FDA's “Class II Special Controls Guidance Document: Surgical Sutures; Guidance for Industry and FDA.” See § 878.1(e) for the availability of this guidance document.
Predicate Devices
PDS II, Synthetic Absorbable Polydioxanone Surgical Sutures (Ethicon, Inc.)
Submission Summary (Full Text)
{0}------------------------------------------------
Image /page/0/Picture/0 description: The image shows a logo for CP Medical in Portland, Oregon. The logo has a black square on the left side with the letters CP in white. To the right of the square, the word "Medical" is written in large, bold, black letters. Below the word "Medical", the words "Portland, Oregon" are written in a smaller, black font.
K013274
P.O. BOX 6724 . PORTLAND, OR 97208 . 503- 232-1555 1-800-950-2-63
# 510(K) SUMMARY
NOV 1 6 2001
This summary of 510(k) safety and effectiveness information is being submitted in accordance with the requirements of Safe Medical Devices Act of 1990. 21 CHR 807.92
| Device Name:<br>Trade Name: | | Mono-Dox. Synthetic Absorbable Suture, Sterile |
|-----------------------------|------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------|
| Common Name(s): | | Suture Synthetic Absorbable Surgical, Polydioxanone |
| Classification Name(s): | | Suture, Absorbable. Synthetic, Polyglycolic Acid |
| Name: | C.P. Medical, Inc.<br>836 N.E. 24th. Ave<br>Portland, Oregon 97232<br>Tele: (503) 232-1555<br>Fax: (503) 230-9993<br>FDA REG.No. 3032563 | Establishment Name, Contact & Registration Number: |
Contact:
### Classification:
Class II Device Class: Classification Panel: General & Plastic Surgery Product Code: GAM
Mary Ann Greenawalt (Director of Regulatory)
#### Intended Use:
Mono-Dox, Monofilament Absorbable Synthetic Surgical Sutures are indicated for use in general soft tissue approximation and/or ligation. including use in pediatric cardiovascular tissue where growth is expected to occur and ophthalmic surgery. Mono-Dox is not indicated for use in adult cardiovascular tissue, microsurgery and neural tissue. These sutures are useful where an absorbable suture with extended wound support (up to six weeks) is desirable.
### Equivalent Predicated Device:
C.P. Medical believes that the Mono-Dox. Absorbable Synthetic (Polydioxanone) Suture is substantially equivalent to the following absorbable suture marketed by Ethicon. Inc.:
PDS II, Synthetic Absorbable Polydioxanone Surgical Sutures
With respect to substantial equivalence, the comparison device represents a virtually identical device. Materials, packaging, sterilization methods, sizes multi- and monofilament, dyed and undyed as well as functional characteristics (absorption rate, strength, etc.). Equivalency can also be drawn with respect to the design, material composition, performance and intended use. Mono-Dox and PDS II sutures both meet or exceed the performance requirements (except for diameter) set forth by USP 24.
U.A. Horenaud
Managing Director
Mary Ann Greenawalt. Director Regulatiny and Quality
{1}------------------------------------------------
Image /page/1/Picture/1 description: The image shows the seal of the Department of Health & Human Services (HHS). The seal features a stylized eagle with three lines representing its body and wings. The words "DEPARTMENT OF HEALTH & HUMAN SERVICES • USA" are arranged in a circular pattern around the eagle.
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
Ms. Mary Ann Greenwalt CP Medical 836 N. E. 24th Avenue Portland, Oregon 97232
Re: K013274
Trade Name: Mono-Dox Synthetic Absorbable PDS Suture Regulation Number: 878.4840 Regulation Name: Polydioxanone Suture Regulatory Class: II Product Code: NEW Dated: September 28, 2001 Received: October 1, 2001
Dear Ms. Greenwalt:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food. Drug. and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA), You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration. Iisting of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
{2}------------------------------------------------
#### Page 2 - Ms. Mary Ann Greenwalt
This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 21 CFR Part 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4659. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97), Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html
Sincerely yours,
Susan Walker, MD
Image /page/2/Picture/5 description: The image contains a handwritten letter 'P' in cursive. The letter is written in black ink on a white background. The letter is slightly tilted to the left.
Celia M. Witten, Ph.D., MD Director
Division of General, Restorative and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{3}------------------------------------------------
NOV 1 6 2001
Prescription Use
(per 21 CFR 801.109)
510(k) Number: K01 3274
Page 1 of 1 .
Device Name(s): Mono-Dox™, Synthetic Absorbable Polydioxanone Suture, Sterile
## Intended Use(s) of the Device:
Mono-Dox, Monofilament Synthetic Absorbable Sutures are indicated for use in all types of soft tissue approximation, including use in pediatric cardiovascular tissue where growth is expected to occur and ophthalmic surgery.
Mono-Dox suture is not indicated for use in adult cardiovascular tissue, microsurgery, and neural tissue. These sutures are useful where an absorbable suture with extended wound support (up to six weeks) is desirable.
Please do not write below this line - continue on another page if necessary Concurrence of CDRH, Office of Device Evaluation (ODE)
Susa Walk
(Division Sig -- 1ff) Division of Concral, Restorative and Neurologal Devices
510(k) Number: `K013274
or
Over-The-Counter Use --------
(Optional format 1-2-96)
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.