K013040 · Minrad, Inc. · MDM · Dec 7, 2001 · General, Plastic Surgery
Device Facts
Record ID
K013040
Device Name
LIGHT SABER INTRODUCER NEEDLE
Applicant
Minrad, Inc.
Product Code
MDM · General, Plastic Surgery
Decision Date
Dec 7, 2001
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 878.4800
Device Class
Class 1
Indications for Use
A single use disposable introducer needle/cannula intended for use with wires in non-vascular procedures. For use with the Dual Radiation Targeting System (ie: DRTS) to improve the accuracy of the needle placement.
Device Story
Single-use disposable introducer needle/cannula; used in non-vascular percutaneous procedures. Integrates with Dual Radiation Targeting System (DRTS) to assist clinicians in accurate needle placement. Device consists of needle, collimator, and cannula/hub assembly. Features female Luer fitting for syringe attachment; depth markings at 1cm intervals. Available in 17, 18, and 19 gauges. Operates as manual surgical instrument; provides physical access path for wires. Benefits patient by facilitating precise needle positioning during procedures.
Clinical Evidence
No clinical data provided; bench testing only.
Technological Characteristics
Stainless steel needle/cannula assembly; female Luer hub compliant with ISO-594 (6% conical fittings). Gauges: 17, 18, 19. Lengths: 1 to 11 inches. Depth markings at 1cm intervals. Manual operation. No software or electronic components.
Indications for Use
Indicated for percutaneous access to the body for non-vascular surgical procedures, specifically for use with the Dual Radiation Targeting System (DRTS) to improve needle placement accuracy.
Regulatory Classification
Identification
A manual surgical instrument for general use is a nonpowered, hand-held, or hand manipulated device, either reusable or disposable, intended to be used in various general surgical procedures. The device includes the applicator, clip applier, biopsy brush, manual dermabrasion brush, scrub brush, cannula, ligature carrier, chisel, clamp, contractor, curette, cutter, dissector, elevator, skin graft expander, file, forceps, gouge, instrument guide, needle guide, hammer, hemostat, amputation hook, ligature passing and knot-tying instrument, knife, mallet, disposable or reusable aspiration and injection needle, disposable or reusable suturing needle, osteotome, pliers, rasp, retainer, retractor, saw, scalpel blade, scalpel handle, one-piece scalpel, snare, spatula, stapler, disposable or reusable stripper, stylet, suturing apparatus for the stomach and intestine, measuring tape, and calipers. A surgical instrument that has specialized uses in a specific medical specialty is classified in separate regulations in parts 868 through 892 of this chapter.
Predicate Devices
Introducer Needle Accessory, Oratec Interventions, Inc.
Light SaberTM Aspiration Needle, MINRAD, Inc.
Submission Summary (Full Text)
{1}------------------------------------------------
K013040
## EXHIBIT A - 510(K) SUMMARY MINRAD, INC. LIGHT SABER™ INTRODUCER NEEDLE
DEC 0 7 2001
Submitter's Name, Address, Telephone Number, Contact Person and Date Prepared
MINRAD, INC. 847 Main Street Buffalo, NY 14203
Phone: (716)-855-1068 Facsimile: (716)-855-1071
Contact Person: John Riggi Director, Regulatory Affairs August 29, 2001 Date Prepared:
#### Name of Device and Name/Address of Sponsor
Light Saber™ Introducer Needle
MINRAD, INC. 847 Main Street Buffalo, NY 14203
#### Common or Usual Name
Surgical Guide Needle/General and Plastic Surgery, Cannula
#### Classification Name
Surgical Guide Needle/General and Plastic Surgery, Cannula
#### Predicate Devices
- 1. Introducer Needle Accessory, Oratec Interventions, Inc.
- 2. Light SaberTM Aspiration Needle, MINRAD, Inc.
{2}------------------------------------------------
# EXHIBIT A - 510(K) SUMMARY MINRAD, INC. LIGHT SABER™ INTRODUCER NEEDLE (cont.)
#### Intended Use
The Light Saber™ Introducer Needle is intended to be a single use disposable The Light Daber introducer needler.amidia micentisa intenducer Needle is generally non-vascular procedures: - The Esgle starter.
indicated to gain percutaneous access to the body for surgical procedures and mulcated to gain percultures with the DRTS to improve the accuracy of needle placement.
### Technological Characteristics
Iological Onaraover Ibereo Needle consists of a needle, a collimator, to which The fight Saber Introducer Neves enclosed in a cannula/hub assembly with a a soyieving tip. The female Luer of the cannula hub, for attachment to the mateling op. The 10to comply with ISO-594 for "Conical fittings with a 6% Syringe, is debigited to ossings of ther medical equipment." The Light (Duer) tor by inges) installer are provided in gauges of 17, 18, and 19 and in Daber - Invodated 11 Sinches. The tip design for these needles will provide icities of 27x, I all a point. Depth markings are standard on the cannula at 1cm intervals.
#### Substantial Equivalence
The MINRAD, INC. Light Saber™ Introducer Needle is substantially The MINI-a-13, 11. 01 he currently marketed devices, which are referenced equivalent to the other odifferences in general indications for use, size of the abover and needle tip configurations, the MINRAD, INC. Light Saber™ Introducer Needle is identical to a combination of its predicate devices. These minor differences raise no new issues of safety or effectiveness. Thus, the MINRAD, INC. Light Saber™ Introducer Needle is substantially equivalent to its predicate devices.
{3}------------------------------------------------
Image /page/2/Picture/1 description: The image shows the logo for the Department of Health & Human Services - USA. The logo is a circular seal with the words "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" around the perimeter. Inside the circle is an abstract image of an eagle.
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
Mr. John Riggi Director, Regulatory Affairs MINRAD, Inc. 847 Main Street Buffalo, New York 14203
DEC 0 7 2001
Re: K013040 Trade/Device Name: Light Saber™ Introducer Needle Regulation Number: 880.5860, 878.4800 Regulation Name: Piston syringe Manual surgical instrument for general use Regulatory Class: II Product Code: FMF, MDM Dated: September 7, 2001 Received: September 10, 2001
Dear Mr. Riggi:
We have reviewed your Section 510(k) premarket notification of intent to market the device we nave reviewed your bector be device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate 101 as sured in the encreated of the enactment date of the Medical Device Amendments, or to coniments provision to May 20, 1976, the occordance with the provisions of the Federal Food, DINEA devices that have been recuired in assee approval of a premarket approval application (PMA). alla Cosmetic 710-11-184, that 20 hot sequence to the general controls provisions of the Act. The Tou may, therefore, market the act include requirements for annual registration, listing of gencial controls provisions of the tice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it IT your device is classified (500 a00 roy ins. Existing major regulations affecting your device can
may be subject to such additional controls. Existing major regulations FR may be subject to such additional controller in the 21, Parts 800 to 898. In addition, FDA may ou found in the Our cements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean Please oe advised that 1 Dr. 3 issualled of a complies with other requirements of the Act mall I DA has made a determinations administered by other Federal agencies. You must of any i cacal statutes and regaranents, including, but not limited to: registration and listing (21 comply with an the Hot 601 CFR Part 801); good manufacturing practice requirements as set CFR Part 807); adomig (21 CFR Part 820); and if applicable, the electronic forth in the quality by stems (Sections 531-542 of the Act); 21 CFR 1000-1050.
{4}------------------------------------------------
Page 2 -- Mr. John Riggi
This letter will allow you to begin marketing your device as described in your Section 510(k) This lotter with and my your e FDA finding of substantial equivalence of your device to a legally prematics noticated. " The station for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and 11 you desire specific arris 809.10 for in vitro diagnostic devices), please contact the Office of additionally 21 Of It Far 8659. Additionally, for questions on the promotion and advertising of Compliance at (301) 59 + + the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). Other general information on your responsibilities under the Act may be obtained from the Oiner general Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html
Sincerely yours,
R. Mark A. Millison
Celia M. Witten, Ph.D., M.D. Director Division of General, Restorative and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{5}------------------------------------------------
# SECTION 5 - INDICATIONS FOR USE
Indications for Use Form
KO13040 510(k) Number (if known):_
Device Name: Light Saber™ Introducer Needle
Intended Use: A single use disposable introducer needle/cannula intended for A single use disposuble wires in non-vascular procedures.
Indications for Use: For use with the Dual Radiation Targeting System (ie: DRTS) to improve the accuracy of the needle placement.
### (PLEASE DO NOT WRITE BELOW THIS LINE -- CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
(Division Sign-Off)
Division of General, Restorative
and Neurological Devices
510(k) Number. K013040
Prescription Use _V (Per 21 C.F.R. 801.109)
OR
Over-The-Counter Use__________________________________________________________________________________________________________________________________________________________
(Optional Format 1-2-96)
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Guidance alerts
New and changed FDA guidance documents, emailed as a daily digest.
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the ? button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only Software as a Medical Device, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (Software as a Medical Device), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.