VANGUARD REPROCESSED FEMORAL COMPRESSION DEVICE

K011832 · Vanguard Medical Concepts, Inc. · NMF · Dec 21, 2001 · Cardiovascular

Device Facts

Record IDK011832
Device NameVANGUARD REPROCESSED FEMORAL COMPRESSION DEVICE
ApplicantVanguard Medical Concepts, Inc.
Product CodeNMF · Cardiovascular
Decision DateDec 21, 2001
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 870.4450
Device ClassClass 2
AttributesTherapeutic

Indications for Use

The femoral compression system is indicated for the compression of the femoral artery or vein following catheterization.

Device Story

Device provides mechanical compression to femoral artery/vein for hemostasis post-catheterization. Consists of arch, pneumatic pressure dome, connector tube, stopcock, belt locks, and woven belt. Clinician places belt around patient hips, positions arch over groin with dome on puncture site, and secures with belt. External pneumatic pump and manometer attach to stopcock; user manually adjusts air pressure in dome to control compression force. Arch and belt distribute opposing force. Vanguard reprocesses previously used devices via cleaning, inspection, testing, repackaging, and sterilization.

Clinical Evidence

Bench testing only. Validation included decontamination, cleaning, sterilization, and functional/performance testing to demonstrate that reprocessed devices perform as intended and maintain safety/effectiveness.

Technological Characteristics

Mechanical compression device comprising arch, pneumatic pressure dome, connector tube, stopcock, belt locks, and woven belt. Operates via manual pneumatic pressure control. Reprocessed device maintains original OEM specifications.

Indications for Use

Indicated for compression of femoral artery or vein post-catheterization. Contraindicated in patients with severe peripheral vascular disease (risk of deep vein thrombosis) and patients with femoral artery or vein grafts (risk of damage).

Regulatory Classification

Identification

A vascular clamp is a surgical instrument used to occlude a blood vessel temporarily.

Predicate Devices

Submission Summary (Full Text)

{0}------------------------------------------------ Image /page/0/Picture/1 description: The image shows the seal of the U.S. Department of Health & Human Services. The seal features a stylized caduceus, a symbol often associated with medicine and healthcare, composed of three parallel lines forming a serpentine shape. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES • USA" is arranged in a circular pattern around the caduceus. The seal is presented in black and white. Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 NOV 1 2004 Vanguard Medical Concepts, Inc. c/o Ms. Heather Crawford Director of Regulatory Affairs 5307 Great Oak Drive Lakeland, FL 33815 Re: K011832 - Supplemental Validation Submission Vanguard Reprocessed Femoral Compression Device Regulation Number: 21 CFR 870.4450 Regulation Name: Clamp, Vascular Regulatory Class: II (2) Product Code: NMF Dated: September 18, 2001 Received: September 24, 2001 Dear Ms. Crawford: The above-referenced premarket notification (510(k)) was cleared by the Office of Device Evaluation (ODE) on December 21, 2001. We have received your supplemental validation data as required for reprocessed single-use devices by the Medical Device User Fee and Modernization Act of 2002. After reviewing your supplemental validation data, we have determined the devices listed in the enclosure accompanying this letter are substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market these devices, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling. and prohibitions against misbranding and adulteration. If your devices are classified (see above) into either class II (Special Controls) or class III (PMA) they may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your devices in the Federal Register. {1}------------------------------------------------ #### Page 2 - k011832 Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your devices comply with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's applicable requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. The FDA finding of substantial equivalence of your devices to legally marketed predicate devices results in classification for your devices and thus, permits you to legally market the devices. This letter will allow you to continue marketing the devices listed in the enclosure accompanying this letter. If you desire specific advice for your devices on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at 240-276-0120 (DOEB). Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html. Sincerely yours, B. Bimmima for Bram D. Zuckerman, M.D. Director Division of Cardiovascular Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosures {2}------------------------------------------------ #### Attachment 1 USCI ® C.R. Bard®, Inc. / RADI Medical Systems AB Model Number: 017500 OEM Trade Name: FemoStop® Femoral Compression System {3}------------------------------------------------ ### Indications for Use 510(k) Number: Device Name: Yanguard Reprocessed Femoral Compression Device Indications for Use: The femoral compression system is indicated for the compression of the femoral artery or vein following catheterization. #### (PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED.) Concurrence of CDRH, Office of Device Evaluation (ODE) Prescription Use V (Per 21 CFR 801.109) OR Over-The-Counter Use (Optional Format 1-2-96) Y. Oele Mch Division of Cardiovascular & Respiratory Devices 510(k) Number K011832 iv {4}------------------------------------------------ K011832 ---- DEC 21 2001 ## 510(k) Summary of Safety & Effectiveness | Submitter | Vanguard Medical Concepts, Inc.<br>5307 Great Oak Drive<br>Lakeland, FL 33815 | |------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | Contact | Mr. Mike Sammon, Ph.D.<br>Director, Research and Development<br>(863) 683-8680, extension 228<br>(801) 327-3339 (facsimile)<br>mikes@safe-reuse.com | | Date | June 14, 2001 | | Device | <ul><li>Trade Names: Vanguard Reprocessed Femoral Compression Device<br/> ⇒ USCI® C. R. Bard®, Inc., RADI Medical Systems AB FemoStop®<br/> Femoral Compression System</li><li>Common Name: Femoral compression device, groin compressor</li><li>Classification: 21 CFR 870.4450 - Vascular Clamp – Class II</li><li>Product Code DXC</li></ul> | | Predicate<br>Device | USCI® C. R. Bard®, Inc., RADI Medical Systems AB FemoStop® Femoral<br>Compression System legally marketed under 510(k) premarket notification<br>K983471 | | Indications for<br>Use | The femoral compression system is indicated for the compression of the<br>femoral artery or vein following catheterization. | | Contra-<br>indications | Femoral compression presents a significant risk for deep vein thrombosis in<br>patients with severe peripheral vascular disease. Femoral artery or vein grafts<br>are also at significant risk for damage with use of this device. | | | Continued on next page | USCI and Bard are registered trademarks of C.R. Bard, Inc. FemoStop is a registered trademark of RADI Medical Systems AB {5}------------------------------------------------ # 510(k) Summary of Safety & Effectiveness, Continued | Device<br>Description | The femoral compression device is used to provide compression of the<br>femoral artery for hemostasis management after catheterization. The device<br>is comprised of an arch with an attached sterile pneumatic pressure dome,<br>connector tube, stopcock and belt locks. A woven belt is used to secure the<br>device onto the patient. | |----------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | | In use, the belt is placed under and around the patient's hips and the arch is<br>placed over the patient's groin with the dome atop the puncture site. The belt<br>is attached to the arch via the adjustable belt locks and is tightened. A<br>pneumatic pump and manometer are attached to the stopcock connector. The<br>user controls the mechanical pressure applied to the puncture site by<br>increasing or decreasing air pressure applied to the dome. The arch and belt<br>absorb and distribute the opposing force from the dome. | | | Vanguard receives previously used compression devices from healthcare<br>facilities; cleans, inspects, tests, repackages and sterilizes the devices; and<br>returns them to the healthcare facility. | | Technological<br>Characteristics | The Vanguard reprocessed compression device is essentially identical to<br>the currently marketed OEM compression device. No changes are made to<br>the currently marketed device's specifications and they possess the same<br>technological characteristics. Biocompatibility and performance/functional<br>testing demonstrate that the devices are equivalent and continue to be safe and<br>effective for their intended use. | | Test Data | Decontamination and cleaning, sterilization validations and<br>functional/performance and biocompatibility testing demonstrates that the<br>reprocessed devices perform as intended and are safe and effective. | | Conclusion | Based on the information provided herein and the 510(k) "Substantial<br>Equivalence" Decision Making Process Chart, we conclude that the Vanguard<br>reprocessed femoral compression device is substantially equivalent to the<br>predicate device, the OEM compression device, USCI® C. R. Bard®, Inc.,<br>RADI Medical Systems AB FemoStop® Femoral Compression System,<br>under the Federal Food, Drug and Cosmetic Act. |
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...